EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
R
>
REYNOLDS RANCH
>
2680
>
2300 - Underground Storage Tank Program
>
PR0535432
>
COMPLIANCE INFO_2010-2011
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/11/2024 3:15:22 PM
Creation date
6/23/2020 6:39:20 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2010-2011
RECORD_ID
PR0535432
PE
2351
FACILITY_ID
FA0020431
FACILITY_NAME
COSTCO WHOLESALE #1091
STREET_NUMBER
2680
STREET_NAME
REYNOLDS RANCH
STREET_TYPE
PKWY
City
LODI
Zip
95240
CURRENT_STATUS
01
SITE_LOCATION
2680 REYNOLDS RANCH PKWY
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2351_PR0535432_2680 REYNOLDS RANCH_2010-2011.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
395
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SWRCB JUNE 2008 <br /> Monitorin Re uirements of Sin le-walled Piping Types <br /> ME <br /> ,Y <br /> •An automatic lineMEE": <br /> rized: • 0.1 gph triennial No requirements if all • 0.1 gph Biennial line test. <br /> leak detector that tomaticline leak line test; criteria are met: <br /> detects a 3.0 gph detector that detects a 3.0 CCR 2643(e) <br /> leak. The automatic gph leak. The automatic AND • below-grade piping <br /> line leak detector line leak detector must be operates at less than <br /> shall be capable of connected to an audible • Daily visual atmospheric pressure. <br /> shutting off the pump and visual alarm to monitoring of suction CCR 2636(a)(3)(A) <br /> when a release indicate a release system for presence <br /> occurs and shall shut malfunction of the system. of air. jlnspection loci • below-grade piping is <br /> down the pumping CCR 2643(c)(1);2666 required.) <br /> sloped so the contents <br /> system automatically <br /> if the automatic line AND CCR 2643(d) drain back into tank if <br /> leak detector fails or suction is released. <br /> 0.2 gph <br /> is disconnected. monthly line CCR 2636(a)(3)(B) <br /> CCR 2643(c);2666 test. <br /> • No valves or pumps <br /> AND CCR 2643(c)(2) installed below grade in <br /> 0.2 gph suction line. <br /> monthly line OR 0.1 gph annual CCR 2636(a)(3)(C) <br /> test. CCR line test. <br /> 643(c)(2) CCR 2643(c)(3) • Only one check valve <br /> installed directly below and <br /> OR 0.1 gph Suction: as close as practical so <br /> annual line • 0.1 gph triennial line test suction pump. <br /> test. AND CCR 2636(a)(3)(C) <br /> CCR 2643(c)(3), • is inspected by method <br /> 2666 • Daily or monthly visual <br /> monitoring of the suction that readily demonstrates <br /> system for presence of air. that requirements are met. <br /> (Inspection lop required.) CCR2636(a)(3)(D) <br /> CCR 2643(d) <br /> Page 5 of 7 <br />
The URL can be used to link to this page
Your browser does not support the video tag.