My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2010-2011
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
R
>
REYNOLDS RANCH
>
2680
>
2300 - Underground Storage Tank Program
>
PR0535432
>
COMPLIANCE INFO_2010-2011
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/11/2024 3:15:22 PM
Creation date
6/23/2020 6:39:20 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2010-2011
RECORD_ID
PR0535432
PE
2351
FACILITY_ID
FA0020431
FACILITY_NAME
COSTCO WHOLESALE #1091
STREET_NUMBER
2680
STREET_NAME
REYNOLDS RANCH
STREET_TYPE
PKWY
City
LODI
Zip
95240
CURRENT_STATUS
01
SITE_LOCATION
2680 REYNOLDS RANCH PKWY
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2351_PR0535432_2680 REYNOLDS RANCH_2010-2011.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
395
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
1 i 0 Item #26 <br />1 <br />If ever required, the <br />pump can be easily <br />removed from the tank <br />by unthreading three <br />bolts. There is no need to <br />disconnect the syphon <br />system, or remove the <br />leak detector from the <br />system to service the IST. <br />This feature reduces the risk <br />causing another. <br />1 <br />11 <br />Ll <br />ng one problem and <br />Pump diagnostics :is reported within moments to remote <br />monitoring parties, reducing service call :time. Serial link <br />allows ATG to control pump preventing water from being <br />pumped, elimination of syphon piping, and other functions <br />designed to reduce station operating costs. <br />FE Petrels quality commitment to supply you with a world <br />class product in accordance with internationally recognized <br />quality standards. <br />IFS: Our intake <br />filter screen <br />option utilizes <br />316 stainless steel + " <br />to filter particles t <br />.009" (.23mm) and <br />larger. It can significantly reduce dispenser <br />filter changes, reducing maintenance costs by <br />hundreds of dollars per year. <br />Power Requirements: <br />• Input power: <br />At 4 hp, 208/230 3 phase 50/60 Hz <br />At 2 hp, 208/230 volt 50/60 Hz, 1 or 3 phase <br />• MagVFC output power: 3 phase variable frequency <br />Pump Motor: <br />• 2 HP or 4 HP: 2 stage centrifugal pump <br />• Maxumum liquid viscosity: <br />70 SSU @ 60 deg F (15.5 deg C) <br />• Maxumum flow rate: 2 hp 110 GPM, 4 hp 140 GPM <br />• Maxumum pressure: 138 feet of head <br />(45 PSI in gasoline) <br />• Maximum amperage: 2 hp 13 amps, 4 hp 18 amps <br />Check Valve: <br />• 2 3/4" (70mm) diameter aluminum/steel construction <br />100% alcohol/gas compatible fluorocarbon seal. <br />Seal Elastomers: <br />• Standard seals are viton and compatible with fuel <br />mixtures containing up to 15% ethanol or methanol <br />with gasoline and 20% MTBE, 17% ETBE, or 17% <br />TAME with gasoline, and diesel fuels, avgas, jet fuel <br />or kerosene <br />• AG models contain "IST" in model number and are for <br />use in fuel mixtures containing any combination of <br />ethanol or methanol and 20% MTBE, 20% ETBE or <br />17% TAME with gasoline. <br />Syphon: <br />• Syphon primer is venture type, capable of 26" (66cm) <br />Hg vacuum <br />• Syphon check valve is machined aluminum, field <br />repairable <br />Variable Speed Controller: <br />• Alternating lead pump and master/slave capability. <br />On demand "auto -start" of additional pumps in <br />manifolded pump applications <br />• Enclosure size is 12" H x 5" W x 9.25"D <br />(30 cm x 13 cm x 23 cm) <br />• Operating temperature 40 to 95 deg F <br />(4 to 35 deg C) <br />Approvals: <br />• UL and CUL, others pending <br />Quality Certification: <br />• FE Petro is an ISO 9001 Certified manufacturer. <br />The MagVFC incorporates <br />a RS 485 serial <br />communications system <br />for communication and <br />intelligence sharing with <br />INCON fuel management <br />systems. <br />1 <br />11 <br />Ll <br />ng one problem and <br />Pump diagnostics :is reported within moments to remote <br />monitoring parties, reducing service call :time. Serial link <br />allows ATG to control pump preventing water from being <br />pumped, elimination of syphon piping, and other functions <br />designed to reduce station operating costs. <br />FE Petrels quality commitment to supply you with a world <br />class product in accordance with internationally recognized <br />quality standards. <br />IFS: Our intake <br />filter screen <br />option utilizes <br />316 stainless steel + " <br />to filter particles t <br />.009" (.23mm) and <br />larger. It can significantly reduce dispenser <br />filter changes, reducing maintenance costs by <br />hundreds of dollars per year. <br />Power Requirements: <br />• Input power: <br />At 4 hp, 208/230 3 phase 50/60 Hz <br />At 2 hp, 208/230 volt 50/60 Hz, 1 or 3 phase <br />• MagVFC output power: 3 phase variable frequency <br />Pump Motor: <br />• 2 HP or 4 HP: 2 stage centrifugal pump <br />• Maxumum liquid viscosity: <br />70 SSU @ 60 deg F (15.5 deg C) <br />• Maxumum flow rate: 2 hp 110 GPM, 4 hp 140 GPM <br />• Maxumum pressure: 138 feet of head <br />(45 PSI in gasoline) <br />• Maximum amperage: 2 hp 13 amps, 4 hp 18 amps <br />Check Valve: <br />• 2 3/4" (70mm) diameter aluminum/steel construction <br />100% alcohol/gas compatible fluorocarbon seal. <br />Seal Elastomers: <br />• Standard seals are viton and compatible with fuel <br />mixtures containing up to 15% ethanol or methanol <br />with gasoline and 20% MTBE, 17% ETBE, or 17% <br />TAME with gasoline, and diesel fuels, avgas, jet fuel <br />or kerosene <br />• AG models contain "IST" in model number and are for <br />use in fuel mixtures containing any combination of <br />ethanol or methanol and 20% MTBE, 20% ETBE or <br />17% TAME with gasoline. <br />Syphon: <br />• Syphon primer is venture type, capable of 26" (66cm) <br />Hg vacuum <br />• Syphon check valve is machined aluminum, field <br />repairable <br />Variable Speed Controller: <br />• Alternating lead pump and master/slave capability. <br />On demand "auto -start" of additional pumps in <br />manifolded pump applications <br />• Enclosure size is 12" H x 5" W x 9.25"D <br />(30 cm x 13 cm x 23 cm) <br />• Operating temperature 40 to 95 deg F <br />(4 to 35 deg C) <br />Approvals: <br />• UL and CUL, others pending <br />Quality Certification: <br />• FE Petro is an ISO 9001 Certified manufacturer. <br />
The URL can be used to link to this page
Your browser does not support the video tag.