My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2010-2011
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
R
>
REYNOLDS RANCH
>
2680
>
2300 - Underground Storage Tank Program
>
PR0535432
>
COMPLIANCE INFO_2010-2011
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/11/2024 3:15:22 PM
Creation date
6/23/2020 6:39:20 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2010-2011
RECORD_ID
PR0535432
PE
2351
FACILITY_ID
FA0020431
FACILITY_NAME
COSTCO WHOLESALE #1091
STREET_NUMBER
2680
STREET_NAME
REYNOLDS RANCH
STREET_TYPE
PKWY
City
LODI
Zip
95240
CURRENT_STATUS
01
SITE_LOCATION
2680 REYNOLDS RANCH PKWY
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2351_PR0535432_2680 REYNOLDS RANCH_2010-2011.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
395
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
fl <br />u <br />fl <br />u <br />CI <br />D <br />n <br />u <br />u <br />11 <br />7 <br />11 <br />[I <br />n <br />n <br />I <br />D <br />11 <br />9 <br />The sensor operating principle uses a series of pressure switches to control the pump and trigger and alarm <br />with pump shutdown. The approximate air or vapor leak rate which would produce an alarm is <br />specified as greater than 85±15 liters per hour for all systems. Leaks larger than this should <br />produce an alarm. <br />Temperature Effects <br />This system was tested over a range of temperature conditions of -25 deg C to 70 deg C. The <br />system (X) did or ( ) did not pass all of these tests. <br />Effects of a Catastrophic Leak <br />A catastrophic leak will cause an immediate shut down of the pump. (X) yes () no <br />Limitations on the Results <br />The performance estimates above are only valid when: <br />• The vacuum source must maintain a flow rate of 85±15 liters per hour during monitoring. <br />• The method has not been substantially changed. <br />• The vendor's instructions for using the method are followed. <br />If this method is affected by other sources of interference. List these interferences below and <br />give the ranges of conditions under which the evaluation was done. (Check None if not <br />applicable.) <br />(X) None known <br />Manifolded tanks require that the interstice of the tanks be manifolded to a common vacuum pump. <br />> Safety disclaimer: This test procedure only addresses the issue of the method's <br />ability to detect leaks. It does not test the equipment for safety hazards. <br />MSR 09-04-A 9 <br />
The URL can be used to link to this page
Your browser does not support the video tag.