My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2010-2011
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
R
>
REYNOLDS RANCH
>
2680
>
2300 - Underground Storage Tank Program
>
PR0535432
>
COMPLIANCE INFO_2010-2011
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/11/2024 3:15:22 PM
Creation date
6/23/2020 6:39:20 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2010-2011
RECORD_ID
PR0535432
PE
2351
FACILITY_ID
FA0020431
FACILITY_NAME
COSTCO WHOLESALE #1091
STREET_NUMBER
2680
STREET_NAME
REYNOLDS RANCH
STREET_TYPE
PKWY
City
LODI
Zip
95240
CURRENT_STATUS
01
SITE_LOCATION
2680 REYNOLDS RANCH PKWY
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2351_PR0535432_2680 REYNOLDS RANCH_2010-2011.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
395
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
1 <br />17 <br />u <br />C <br />1 <br />�L] <br />i <br />u <br />11 <br />0 <br />Evaluation Results <br />Note: If the test data can be presented in a more appropriate manner, the evaluator may <br />select to present the information below in a data table, which can be attached to these <br />forms. <br />Specificity -This sensor will respond to any liquid after its threshold is exceeded but <br />testing was conducted only with brine <br />Additional Limitations or Considerations -.None <br />Is-ruelag 1017 • - •' <br />Certification of Results <br />I certify that the liquid level sensor was tested under conditions according to the <br />vendor's operating instructions. I also certify that the evaluation was performed using <br />methods described in the attached Alternative EPA Test Procedures for Liquid level <br />sensors, and that the results presented above are those obtained during the evaluation. <br />H. Kendall Wilcox <br />(printed name) <br />(signature) <br />M <br />Liquid Level Sensor - Results Form <br />Ken Wilcox Associates, Inc. <br />(organization performing evaluation) <br />Grain Valley, MO 64029 <br />(city, state, zip) <br />(816) 443-2494 <br />Page 2 of 2 <br />Product <br />Parameter <br />Brine <br />Threshold - Lower Detection Limit (inches) <br />0.793 <br />Precision - Standard Deviation (inches) <br />0.00184 <br />Detection Time (seconds) <br /><15 <br />Fall Time (seconds) <br /><15 <br />Specificity -This sensor will respond to any liquid after its threshold is exceeded but <br />testing was conducted only with brine <br />Additional Limitations or Considerations -.None <br />Is-ruelag 1017 • - •' <br />Certification of Results <br />I certify that the liquid level sensor was tested under conditions according to the <br />vendor's operating instructions. I also certify that the evaluation was performed using <br />methods described in the attached Alternative EPA Test Procedures for Liquid level <br />sensors, and that the results presented above are those obtained during the evaluation. <br />H. Kendall Wilcox <br />(printed name) <br />(signature) <br />M <br />Liquid Level Sensor - Results Form <br />Ken Wilcox Associates, Inc. <br />(organization performing evaluation) <br />Grain Valley, MO 64029 <br />(city, state, zip) <br />(816) 443-2494 <br />Page 2 of 2 <br />
The URL can be used to link to this page
Your browser does not support the video tag.