My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2010-2011
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
R
>
REYNOLDS RANCH
>
2680
>
2300 - Underground Storage Tank Program
>
PR0535432
>
COMPLIANCE INFO_2010-2011
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/11/2024 3:15:22 PM
Creation date
6/23/2020 6:39:20 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2010-2011
RECORD_ID
PR0535432
PE
2351
FACILITY_ID
FA0020431
FACILITY_NAME
COSTCO WHOLESALE #1091
STREET_NUMBER
2680
STREET_NAME
REYNOLDS RANCH
STREET_TYPE
PKWY
City
LODI
Zip
95240
CURRENT_STATUS
01
SITE_LOCATION
2680 REYNOLDS RANCH PKWY
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2351_PR0535432_2680 REYNOLDS RANCH_2010-2011.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
395
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ONITOA NG SYSTEM CERTIFIC ION <br /> F By All Jurisdictions Vthin the State of California <br /> Authority Cited:Chapter 6.7,Hea and Safety Code;Chapter 16,Division 3 Title 23, Ca nia Code of Regulations <br /> This form mus=e d to document testing and servicing of monitoring equipment. If more than one monitoring system control panel is installed at the facility,a separate <br /> certification ormust be prepared for each monitoring system control panel by the technician who performs the work. A copy of this form must be provided to the tank <br /> system owner/operator. The owner/operator must submit a copy of this form to the local agency regulating UST systems within 30 days of test date. <br /> A.General Information <br /> Facility Name: COSTCO LODI City: LODI CA Zip:95240 <br /> Site Address: 322 E.HARNEY LANE Contact Phone No: 964-0180 <br /> Date of Testing/Service: 05/27/2011 <br /> Facility Contact Person: MANAGER <br /> Make/Model of Monitoring System:TLS 350 R Work Order Number: 2281427 <br /> B.Inventory of Equipment Tested/Certified <br /> Check the appropriate boxes to indicate specific equipment inspected/serviced <br /> Tank ID: 87-A Tank ID: 87-B <br /> X In-Tank Gauging Probe. Model: MAG PLUS X In-Tank Gauging Probe. Model: MAG PLUS <br /> X Annular Space or Vault Sensor. Model: 301 Annular Space or Vault Sensor. Model: 301 <br /> X Piping Sump/Trench Sensogs). Model: MAG/304 Piping Sump/Trench Sensogs). Model: MAG/304 <br /> �( Fill Sump Sensogs). Model: MAG/304 Fill Sump Sensor(s). Model: MAG/304 <br /> Mechanical Line Leak Detector. Model: Mechanical Line Leak Detector. Model: <br /> �( Electronic Line Leak Detector. Model: PLLD X Electronic Line Leak Detector. Model: PLLD <br /> XTank Overfill/High-Level Sensor. Model: EXT ALARM Tank Overfill/High-Level Sensor. Model: EXT ALARM <br /> Other(specify equipment type and model in Section E on page 2). X Other(specify equipment type and model in Section E on page 2). <br /> Tank ID: tJKtM Tank ID: <br /> 71 In-Tank Gauging Probe. Model: MAG PLUS In-Tank Gauging Probe. Model: <br /> )( Annular Space or Vault Sensor. Model: 301 Annular Space or Vault Sensor. Model: <br /> X Piping Sump/Trench Sensogs). Model: MAG/304 Piping Sump/Trench Sensogs). Model: <br /> X Fill Sump Sensogs). Model: MAG/304 Fill Sump Sensogs). Model: <br /> Mechanical Line Leak Detector. Model: Mechanical Line Leak Detector. Model: <br /> X Electronic Line Leak Detector. Model: PLLD Electronic Line Leak Detector. Model: <br /> Tank Overfill/High-Level Sensor. Model: EXT ALARM Tank Overfill/High-Level Sensor. Model: <br /> Other(specify equipment type and model in Section E on page 2). Other(specify equipment type and model in Section E on page 2). <br /> Dispenser : 1/2 Dispenser ID: 3/4 <br /> ®Dispenser Containment Sensors) Model: 323/304 X Dispenser Containment Sensors) Model:323/304 <br /> FX—]Shear Valve(s). X Shear Valve(s) <br /> ElDispenser Containment Float(s)and Chain(s). 7 Dispenser Containment Float(s)and Chain(s). <br /> Dispenser ID: 5/6 Dispenser ID: 7/8 <br /> 0 Dispenser Containment Sensor(s) Model:323/304 X Dispenser Containment Sensors). Model:323/304 <br /> FX-] Shear Valve(s). Shear Valve(s). <br /> 11 Dispenser Containment Float(s)and Chain(s). Dispenser Containment Float(s)and Chain(s). <br /> Dispenser ID: 9/10 Dispenser ID: 11/12 <br /> RI Dispenser Containment Sensors) Model:323/304 1^1 Dispenser Containment Sensors). Model:323/304 <br /> QX Shear Valve(s). X Shear Valve(s). <br /> 10 Dispenser Containment Float(s)and Chain(s). Dispenser Containment Float(s)and Chain(s). <br /> If the facility contains more tanks or dispensers,copy this form.Include information for every tank and dispenser at the facility. <br /> C. Certification <br /> I certify that the equipment identified in this document was inspected/serviced in accordance with the manufacturers'guidelines. <br /> Attached to this certification is information(e.g manufacturers'checklists)necessary to verify that this information is correct. <br /> and a Site Plan showing the layout of monitoring equipment.For any equipment capable of generating such reports,I have also attached <br /> a copy of the(Check all that apply): ❑X System set-up X❑Alarm history report <br /> Technician Name(print): KRISTOPHER BELL Signature: <br /> Certification No.: 833709 License.No.: 743160(Class'A'General Enginering Contractor License) <br /> Testing Company Name:Tanknology Phone No.: (800)800-4633 <br /> Site Address: 11000 N.MoPac Expressway,suite 500,Austin,TX 78759 Date of Testing/Servicing: 05/27/2011 <br /> Monitoring System Certification Page 1 of 3 Based on CA form dated 03/08 <br />
The URL can be used to link to this page
Your browser does not support the video tag.