My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2010-2011
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
R
>
REYNOLDS RANCH
>
2680
>
2300 - Underground Storage Tank Program
>
PR0535432
>
COMPLIANCE INFO_2010-2011
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/11/2024 3:15:22 PM
Creation date
6/23/2020 6:39:20 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2010-2011
RECORD_ID
PR0535432
PE
2351
FACILITY_ID
FA0020431
FACILITY_NAME
COSTCO WHOLESALE #1091
STREET_NUMBER
2680
STREET_NAME
REYNOLDS RANCH
STREET_TYPE
PKWY
City
LODI
Zip
95240
CURRENT_STATUS
01
SITE_LOCATION
2680 REYNOLDS RANCH PKWY
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2351_PR0535432_2680 REYNOLDS RANCH_2010-2011.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
395
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
INDIVIDUAL TANK INFORMATION AND TEST RESULTS <br /> r MW*n <br /> TEST DATE:05/26/11 8501 N MOPAC EXPRESSWAY,SUITE 400 WORK ORDER NUMBER2281425 <br /> CLIENT:COSTCO WHOLESALE AUSTIN,TEXAS 78759(512)451-6334 SITE:COSTCO LODI <br /> Tank ID: 87-B 2 Tank manifolded: NO Bottom to top fill in inches: 179.o <br /> Product: REG UNLEAD Vent manifolded: YES Bottom to grade in inches: 199.o <br /> Capacity in gallons: 29,816 Vapor recovery manifolded: YES Fill pipe length in inches: 60.0 <br /> Diameter in inches: 119.00 Overfill protection: YES Fill pipe diameter in inches: 4.0 <br /> Length in inches: 629 Overspill protection: YES Stage I vapor recovery: DUAL <br /> Material: DW FISERG Installed: ATG Stage II vapor recovery: ASSIST <br /> CP installed on: <br /> COMMENTS <br /> Provides product for disp 3/4,7/8,11/12,15/16 <br /> Start(in) End(in) <br /> Dipped Water Level: 0.00 0.00 New/passed Failed/replaced New/passed Failed/replaced <br /> Dipped Product Level: 96.00 96.00 L.D.#1 L.D.#1 L.D.#2 L.D.#2 <br /> Probe Water Level: 0.071 0.071 Make: <br /> Ingress Detected: Water N Bubble N UllageN Model: <br /> Test time: 12:49-14:20 S/N: <br /> Inclinometer reading: 0.00 Open time in sec: <br /> Holding psi: <br /> VBCuTeCt Test Type: Multiple tanks Resiliency cc: NOT NOT <br /> VacuTect Probe Entry Point: Fill Test leak rate ml/m: TESTED TESTED <br /> Pressure Set Point: 2.16 Metering psi: <br /> Tank water level in inches: 0.00 Calib.leak in gph: <br /> Water table depth in inches: 204.00 Results: <br /> Determined by(method): MONTR WELL <br /> Result: PASS <br /> COMMENTS <br /> COMMENTS <br /> Wet Annular DW/FRP tanks. Vent and Vapor lines <br /> tested with this test. <br /> MEMO= EM <br /> Material: DW FIBERG <br /> Diameter(in): 2.0 <br /> Length(ft): 175.0 <br /> Test psi: 5o <br /> Bleedback cc: 104 <br /> Test time(min): 30 NOT NOT NOT <br /> Start time: 11:17 TESTED TESTED TESTED <br /> End time: 11:47 <br /> Final gph: 0.000 <br /> Result: PASS <br /> Pump type: PRESSURE <br /> Pump make: FE PETRO <br /> COMMENTS Impact Valves Operational: YES <br /> Printed 06/02/201107:48 <br />