My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2010-2011
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
R
>
REYNOLDS RANCH
>
2680
>
2300 - Underground Storage Tank Program
>
PR0535432
>
COMPLIANCE INFO_2010-2011
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/11/2024 3:15:22 PM
Creation date
6/23/2020 6:39:20 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2010-2011
RECORD_ID
PR0535432
PE
2351
FACILITY_ID
FA0020431
FACILITY_NAME
COSTCO WHOLESALE #1091
STREET_NUMBER
2680
STREET_NAME
REYNOLDS RANCH
STREET_TYPE
PKWY
City
LODI
Zip
95240
CURRENT_STATUS
01
SITE_LOCATION
2680 REYNOLDS RANCH PKWY
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2351_PR0535432_2680 REYNOLDS RANCH_2010-2011.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
395
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Pq.0 t ty <br /> �o ca SAN JOAQUIN COUNTY <br /> ENVIRONMENTAL HEALTH DEPARTMENT <br /> NAY 600 East Main Street, Stockton, CA 95202-3029 <br /> ;P Telephone:(209)468-3420 Fax: (209)468-3433 Web:www.segov.org/ehd <br /> q�IFORa` <br /> UNDERGROUND STORAGE TANK (UST) PROGRAM SERVICE REQUEST INSPECTION REPORT <br /> FP <br /> Fa 'lity Name: Inspection Date: <br /> F t Fa <br /> S ice Request#: <br /> K�. <br /> Onsite Service Tec ician's Name: ICC Service Technrcianlinstaller Exp.Date: Manufacturer Training: <br /> SERVICE SERVICE <br /> Leak detector , bucket Spill III minimum 5 gallon <br /> ❑ mechanical Model: <br /> El ❑ electronic Serial: ,D 1 hour hydrostatic ❑ Incon TS-STS <br /> El line test programmed <br /> ❑ Caldwell System El Other <br /> Leak detector '�A I Spill bucket minimum 5 gallon <br /> ❑ ❑ mechanical Model: >�P l hour hydrostatic ❑ Incon TS-STS <br /> ❑ electronic Serial#: ❑ Caldwell System ❑ Other <br /> ❑ line test programmed <br /> sensor Q;7 hr t I Primary piping testing at: <br /> ❑ positive shutdown Model: I� VAId, ❑ psi <br /> ❑ fail safe Serial#: a minutes <br /> ❑ NA <br /> sensor Secondary containment testing for: <br /> ❑ ❑ positive shutdown Model: UDC(s) Piping <br /> ❑ fail safe Serial#: Sump(s) UST(s) <br /> ❑ NA <br /> sensor ❑ Testing for the above components are next due by: <br /> ❑ ❑ positive shutdown Model: <br /> ❑ fail safe Serial#: Note: Please be aware that 2°containment components are required to be tested upon <br /> ❑ NA installation,6 months after,and every 36 months thereafter. <br /> ❑ Drop tube with mechanical overfill at 95% ❑ Cold start of monitoring panel <br /> ❑ Drop tube with mechanical overfill at 95% ❑ Corrosion protection <br /> T 1-11 <br /> Overfill prevention (see LG letter 150-1) 16,4 ❑ Other: see below <br /> ❑ This UST facility is APPROVED to operate This UST facility is NOT APPROVED to operate <br /> t - <br /> nrl� pie <br /> t s. k I <br /> p ( <br /> r <br /> � n 1 Q <br /> THIS FACILITY IS SUBJECT TO REINSPECTION AT ANY TIME AT EHD'S CURRENT HOURLY RATE. <br /> EHD Inspector r/�A� Rseq�`�- Titles <br /> EHD 23-04 UST SERVICE REQUEST INSPECTION REPORT <br /> Rev 10/06/10 <br />
The URL can be used to link to this page
Your browser does not support the video tag.