My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2013-2015
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
R
>
REYNOLDS RANCH
>
2680
>
2300 - Underground Storage Tank Program
>
PR0535432
>
COMPLIANCE INFO_2013-2015
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/12/2024 4:04:53 PM
Creation date
6/23/2020 6:39:39 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2013-2015
RECORD_ID
PR0535432
PE
2351
FACILITY_ID
FA0020431
FACILITY_NAME
COSTCO WHOLESALE #1091
STREET_NUMBER
2680
STREET_NAME
REYNOLDS RANCH
STREET_TYPE
PKWY
City
LODI
Zip
95240
CURRENT_STATUS
01
SITE_LOCATION
2680 REYNOLDS RANCH PKWY
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2351_PR0535432_2680 REYNOLDS RANCH_2013-2015.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
407
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
BCE#14573 <br /> 1. MONITORING: All monitoring equipment must be listed in the State Waster Resources Control Board <br /> Division of Clean Water Program Local Guidance Letter 113. <br /> Check Code <br /> Box Section <br /> All secondary containment units (e.g. tank annular spaces, secondary piping, sumps, <br /> ® <br /> 23 CCR under-dispenser containment, etc.) monitored for leaks using approved electronic leak <br /> 2636(f) detections stems. <br /> All sensors must be located at the lowest possible point so that they may detect a leak <br /> at the earliest opportunity. <br /> Electronic monitoring sensors located at the following points: <br /> ° At the bottom of the interstitial space of each secondarily-contained tank, <br /> positioned as near as possible to the bottom of the tank. <br /> Manufacturer Veeder-Root Model 794380-303 <br /> ° In each collection sump, positioned as near as possible to the bottom of the <br /> collection sump. Additionally, in any sump acting as secondary containment for <br /> unused tank openings which connect to the primary space. <br /> 23 CCR Manufacturer Veeder-Root Model 94380-323 <br /> ® 2632 <br /> 2630(d) <br /> ° In dispenser pans which do not drain into secondary containment piping. <br /> (Note:A mechanical switch which triggers a shear valve may be substituted but <br /> this system will not qualify for the annual line tightness test exemption under 23 <br /> CCR 2636(8)). <br /> Manufacturer NSA Model <br /> ❑Along secondarily-contained pipe runs which do not meet the 114 inch-per-foot <br /> slope requirement, positioned in the depressed or low-lying areas. <br /> Manufacturer Veer-Root Model 794380-208 <br /> 23 CCR Automatic line leak detectors installed to monitor underground pressurized piping. <br /> 2636(f) <br /> ® HSC Manufacturer FE Petro Model STP-MLD-D <br /> 25290.1 h <br /> 25290.2 <br /> Alarm panel provides both audible and visual alarms. It is located in a protected area <br /> and within sight and hearing distance of on-site personnel and hard-wired to a <br /> 23 CCR dedicated circuit. <br /> ® 2632(c)(2)(B) Existing <br /> Manufacturer Veeder-Root Model TLS350R <br /> J. OTHER COMPONENT INFORMATION: <br /> COMPONENT MANUFACTURER MODEL COMPOSITION <br /> Containment DW PTS (WT34) FRP <br /> SUMP Solutions <br /> UNDER-DISPENSER N/A <br /> CONTAINMENT <br /> PENETRATIONS Bravo T2 <br /> 2-TS-AD-CO FRP <br /> Revised 8/1/11 8 <br />