Laserfiche WebLink
SAN JOAQUIN COUNTY <br /> ENVIRONMENTAL HEALTH DEPARTMENT <br /> 1868 East Hazelton Avenue, Stockton,California 95205-6232 <br /> Telephone:(209)468-3420 Fax:(209)466-3433 Web:www.sjgov.ofg/ehd <br /> UNDERGROUND STORAGE TANK(UST) PROGRAM INSPECTION REPORT CONTINUED <br /> Fad'4 Dameron Hospital Facility 525 W Acacia, Stockton pat U0f1 Feb 1, 2013 <br /> Name: p Address: <br /> VIOLATIONS <br /> I$ L1 C2 M COtle SeCIIOn 1';W=CA Haab and Cnd a,CFR=Ceutw rA FMpml R Wafinnc <br /> C1=Class 4 violation;C2=Class 2 vVelion:M=Minor violatbn <br /> Non=t'ressurizcd Pt in continued) <br /> 702 CCR 2643(e) Biennial tightness test of gravity piping not perforated pre-January 1,1984 (M1 <br /> Ina C(R 2fi43(d) Trtenniai line test for conventional wdion piping not performed(pre-Janus 1,1984) (M1) <br /> Other Viorations <br /> 999 Other: See attached"Continuation--Offidal Inspection Report"for violation(s)not listed above. <br /> SUMMARY OF VIOLATIONS <br /> CLASS I CLASS II or MINOR-Notice to Comply) <br /> This is a Routine and Monitoring System Certification inspection. 'The following are Minor-Notice to <br /> Comply violations: #311, 313 <br /> 311. The mechanical line leak detector could not be tested because the turbine pump, which power has <br /> been disconnected, could not be turned on, All line leak detectors shall be capable of detect'incl a 3- <br /> gallon per hour leak at 10 psi, and be tested annually. Immediately have a properly licensed, trained, <br /> and certified tester test the above detector under EIAD inspection. Notification of testing must be <br /> submitted by fax (468•-3433) to EHD at least 2 clays in advance. <br /> 313. The direct-bury spill container failed when tested. All spill containers shall have a minimum <br /> rapacity of five gallons and he r_.apable of containing a sail or ovorfill until it is dPt€..(.JP.d or cleaned lip. <br /> Immediately discontinue deposition of petroleum into this tank until the component is repaired or <br /> replaced by a properly licensed, trained, and certified contractor under permit and inspection of the EIAD, <br /> If the spill container can't be replaced immediately, there is a possibility that the UST system may be red <br /> tagged to prevent fuel inputs. <br /> NOTES <br /> The technician on site provided the following manufacturer's certifications: <br /> Petro Tite Test (for line test) Expiration 0/3/13 <br /> VMI catastrophic testing: Expiration 11110/13 <br /> Leak Alert: CN120588 Expiration 11/7/12 <br /> Ob6eived annual lite tightness test. passes! <br /> Received copy of latest Financial Responsibility on site policy period from '12/28/2012 to 12/18/2013. <br /> Previous Financial Responsibility document on file covers 2/23/2012 to 2/23/2013. <br /> Designated Operator Monthly Inspection Reports for March, April, May, October,September, November, <br /> December 2012, and January 2013, referenced "suction" on leak detector section on page 2. This is <br /> incorrect. Please document all future designated operator monthly inspection reports accurately. <br /> ALL END STArr TIME ASSOCIATED WITti FAILING TO COMPLY BY THE ABOVE NOTED DATES WILL BE BILLED AT THE CURRENT HOURLY RATE. <br /> FACILITY IS SUBJECT TO REINSPECTION AT ANY TIME AT EHD'S CURRENT HOURLY RATE. <br /> In Title!EH 2 TRev /19112 Page 3 UST INSPECTION REPORT <br />