My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_1987-2014
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
A
>
ACACIA
>
525
>
2300 - Underground Storage Tank Program
>
PR0231002
>
COMPLIANCE INFO_1987-2014
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/19/2024 1:24:08 PM
Creation date
6/23/2020 6:39:53 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1987-2014
RECORD_ID
PR0231002
PE
2361
FACILITY_ID
FA0002864
FACILITY_NAME
DAMERON HOSPITAL
STREET_NUMBER
525
Direction
W
STREET_NAME
ACACIA
STREET_TYPE
ST
City
STOCKTON
Zip
95203
APN
13715304
CURRENT_STATUS
01
SITE_LOCATION
525 W ACACIA ST
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231002_525 W ACACIA_1987-2014.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
507
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN JOAQUIN COUNTY <br /> ENVIRONMENTAL HEALTH DEPARTMENT <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone:(209)468-3420 Fax:(209)468-3433 Web:www.sigov.org/ehd <br /> UNDERGROUND STORAGE TANK(UST) PROGRAM INSPECTION REPORT CONTINUED <br /> Facility Dameron Hospital Address : 525 W Acacia, Stockton Date: <br /> Name: Feb 1, 2013 <br /> VIOLATIONS <br /> # C1 C2 M Code S@CtlOrt HSC=CA Health and Safe Code;CFR=Code of Federal Regulations <br /> C1=Class 1 violation;C2=Class 2 violation;M=Minor violation <br /> am <br /> 702 CCR 2643(e) Biennial tightness test of gravity piping not performed(pre-January 1,1984) (M7) <br /> 703 CCR 2643(d) Triennial line test for conventional suction piping not performed(pre-January 1, 1984) (Mi) <br /> 999 Other: See attached"Continuation—Official Inspection Report"for violation(s)not listed above. <br /> SUMMARY OF VIOLATIONS <br /> CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> This is a Routine and Monitoring System Certification inspection. The following are Minor-Notice to <br /> Comply violations: # 311, 313 <br /> 311. The mechanical line leak detector could not be tested because the turbine pump, which power has <br /> been disconnected, could not be turned on. All line leak detectors shall be capable of detecting a 3- <br /> gallon per hour leak at 10 psi, and be tested annually. Immediately have a properly licensed, trained, <br /> and certified tester test the above detector under EHD inspection. Notification of testing must be <br /> submitted by fax (468-3433) to EHD at least 2 days in advance. <br /> 313. The direct-bury spill container failed when tested. All spill containers shall have a minimum <br /> capacity of five gallons and be capable of containing a spill or overfill until it is detected or cleaned up. <br /> Immediately discontinue deposition of petroleum into this tank until the component is repaired or <br /> replaced by a properly licensed, trained, and certified contractor under permit and inspection of the EHD. <br /> If the spill container can't be replaced immediately, there is a possibility that the UST system may be red <br /> tagged to prevent fuel inputs. <br /> NOTES <br /> The technician on site provided the following manufacturer's certifications: <br /> Petro Tite Test (for line test) Expiration 9/3/13 <br /> VMI catastrophic testing: Expriation 11/10/13 <br /> Leak Alert: CN 120588 Expiration 11/7/12 <br /> Observed annual line tightness test: passed <br /> Received copy of latest Financial Responsibility on site policy period from 12/28/2012 to 12/18/2013. <br /> Previous Financial Responsibility document on file covers 2/23/2012 to 2/23/2013. <br /> Designated Operator Monthly Inspection Reports for March, April, May, October,September, November, <br /> December 2012, and January 2013, referenced "suction" on leak detector section on page 2. This is <br /> incorrect. Please document all future designated operator monthly inspection reports accurately. <br /> ALL EHD STAFF TIME ASSOCIATED WITH FAILING TO COMPLY BY THE ABOVE NOTED DATES WILL BE BILLED AT THE CURRENT HOURLY RATE. <br /> PP FACILITY IS SUBJECT TO REINSPECTION AT ANYTIME AT EHD'S CURRENT HOURLY RATE. <br /> Ins for Ar Rved Title: <br /> 04 <br /> EHQeg2 Rev4/19/12 Page 3 UST INSPECTION REPORT <br />
The URL can be used to link to this page
Your browser does not support the video tag.