Laserfiche WebLink
• • <br /> S A N ,J O A Q U I N AMENDED Environmental Health Department <br /> C 0 U N TY-- <br /> Underground <br /> Y---. Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> DSS COMPANY 655 W CLAY ST, STOCKTON July 24,2018 <br /> UST System Observations <br /> 319 CCR 2635(b) No spill bucket,failed to contain five gallons,or failed to provide a means to keep it empty ❑V ❑R ❑COS <br /> 320 CCR 2635(b)(2) Overfill prevention system not present or failed to meet overfill requirements ❑V ❑R ❑COS <br /> 321 CCR 2635(b)(2) Overfill prevention was overridden ❑V ❑R ❑COS <br /> 322 HSC 25281.6(a) Unburied below grade emergency generator system failed to meet exemption status ❑V ❑R ❑COS <br /> 323 HSC 25283.5(a) Unburied below grade UST system failed to meet exemption status ❑V ❑R ❑COS <br /> 324 CCR 2717.1(g) Tampered with red tag ❑V ❑R ❑COS <br /> 325 CCR 2717.1(f) Deposited petroleum into a red tagged UST ❑V ❑R ❑COS <br /> 326 HSC 25299(a)(9) Tampered with or disabled leak detection devices or alarms ❑V ❑R ❑COS <br /> 327 CCR 2631.1 UST system not compatible with the substance stored ❑V ❑R ❑COS <br /> 328 HSC 25298 Failed to comply with temporary closure requirements ❑V ❑R ❑COS <br /> 329 HSC 25298 Failed to comply with all permanent closure requirements ❑V ❑R ❑COS <br /> 330 CCR 2636(f)(6) Failure to meet all requirements in lieu of a line leak detector for emergency generator tank system ❑V ❑R ❑COS <br /> 331 CCR 2630(d) Secondarily contained piping not maintained to allow liquid to drain into sump ❑V ❑R ❑COS <br /> 332 CCR 2631(b),2631(d) Primary and/or secondary containment not constructed in accordance with the established standards ❑V ❑R ❑COS <br /> Single-Walled Non-Pressurized Piping <br /> 401 CCR 2636(a)(3) Suction piping not properly sloped or incorrectly located check valve ❑V ❑R ❑COS <br /> 402 CCR 2643(d) Daily monitoring of suction pipe(pre-Jan 1984)not performed ❑V ❑R ❑COS <br /> 403 CCR 2643(d) Triennial 0.1 gph line test for conventional suction piping not performed(pre-January 1984) ❑V ❑R ❑COS <br /> 404 CCR 2643(e) Biennial 0.1 gph test for gravity piping not performed(pre-January 1984) ❑V ❑R ❑COS <br /> i ' 'Othet�olatians ,f~. ;: <br /> 2010 See below Unlisted General violation ❑V ❑R ❑COS <br /> a ..:. <br /> SUMMARY QF VtOLAT10NS <br /> (CLASS I,CLASS IL or ININOR-Notice to Comply] ',';.. <br /> Item# Remarks <br /> 105 CCR 2632(d)(1), 2634(d) Failed to have an approved UST monitoring plan. <br /> The monitoring plan is not current and/or not approved by the EHD. In the 87 product monitoring plan under the <br /> section"under dispenser containment(UDC)monitoring"it states"YES"for the"UDC monitoring stops flow of <br /> product at dispenser"however while out on the field, the inspector observed the STP having positive shutdown with <br /> the alarm of the UDC sensor.The UDC monitoring does not"stop the flow of product at the dispenser"it stops at <br /> the STP. On the Diesel dispenser the monitoring plan states YES under"failure/disconnection of UDC monitoring <br /> system triggers automatic pump shutdown"however the diesel dispenser has a suction system and the <br /> disconnection/failure of the sensor does not trigger an automatic pump shutdown. The monitoring plan must be <br /> uploaded to the California Environmental Reporting System (CERS). Immediately log into CERS,make the <br /> necessary changes,and submit for review by the EHD. <br /> This is a minor violation. <br /> FA0003699 PR0231065 SCO01 07/24/2018 <br /> EHD 23-01 Rev.10/31/2017 Page 3 of 5 Underground Storage Tank Program OIR <br /> 1868 E. Hazelton Avenue( Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />