My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_1987-2000
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
CLAY
>
655
>
2300 - Underground Storage Tank Program
>
PR0231065
>
COMPLIANCE INFO_1987-2000
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/9/2022 12:59:37 PM
Creation date
6/23/2020 6:40:15 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1987-2000
RECORD_ID
PR0231065
PE
2361
FACILITY_ID
FA0003699
FACILITY_NAME
DSS COMPANY
STREET_NUMBER
655
Direction
W
STREET_NAME
CLAY
STREET_TYPE
ST
City
STOCKTON
Zip
95206
APN
14707110
CURRENT_STATUS
01
SITE_LOCATION
655 W CLAY ST
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231065_655 W CLAY_1987-2000.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
403
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
MAY -26-99 09:01A He lmi 0 <br />& Ler-nQr Inc--- P-01 <br />"EXHIBIT B" <br />UNDERGROUND TANK MONITORING PLAN <br />AND EMERGENCY RESPONSE PLAN <br />Date; January 4, 1999 <br />Facility: DSS Engineering Contractors <br />655 West Clay Street <br />Stockton, California <br />Tank: One 20,000 -gallon diesel storage tank and one 6,000 gallon gasoline storage tank <br />The underground storage tanks at this site are double-wall tanks manufactured by Xerxes. <br />Underground piping is double wall. A sensor in the tank sump accomplishes monitoring of the <br />underground suction piping. A sensor in the tank sump and automatic pump shutdown accomplishes <br />monitoring of the underground pressure piping. The secondary, containment pipe is open to the piping <br />manhole sump so a piping leak would run into the sump. <br />The tanks are monitored continuously by an lncon n-ionitoring system with liquid sensors located in the <br />double-wall tank annular spaces and in the tank manhole sump tanks. Automatic pump shutdown is <br />included for the submersible pump. The Tncon tank monitor i, located inside the building and has a <br />local alarm. Alarm reports are checked daily. <br />The tank monitoring system is tested and maintained by a certified third party company on an annual <br />basis. <br />In the event of a leak or spill, the operator of the underground tank will notify the San Joaquin County <br />Environmental Health Division at (209) 468-3420, <br />DSS will notify the following company for the fastest cleanup of the spill or leak possible: <br />Stockton Service Station Equipment <br />(209) 464-833:3 <br />Stockton Service Station Equipment maintains or has access to absorbent materials, suction pumps, <br />and other equipment for cleanup of spills, and removal of spills, and removal of leaked material from <br />secondary spaces. <br />Person responsible for authorizing work: Dan Silva, DSS Engineering Contractors, 639 West Clay <br />Street, Stockton, CA 95206 (209) 948-0302, <br />