My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2002-2015
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
CLAY
>
655
>
2300 - Underground Storage Tank Program
>
PR0231065
>
COMPLIANCE INFO_2002-2015
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/9/2022 2:10:00 PM
Creation date
6/23/2020 6:40:20 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2002-2015
RECORD_ID
PR0231065
PE
2361
FACILITY_ID
FA0003699
FACILITY_NAME
DSS COMPANY
STREET_NUMBER
655
Direction
W
STREET_NAME
CLAY
STREET_TYPE
ST
City
STOCKTON
Zip
95206
APN
14707110
CURRENT_STATUS
01
SITE_LOCATION
655 W CLAY ST
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231065_655 W CLAY_2002-2015.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
484
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
n • <br /> Troubleshoong lns Ila4 <br /> � Y <br /> MAR 1 9 2015 <br /> Troubleshooting the Installation <br /> ENVIRONMENTAI <br /> WARNING!Lockout and tag power before performing either of these two procedures. <br /> 1. If nuisance tripping occurs,check for proper heaters,loose connections,and severe arcing or pitting of <br /> contacts. <br /> Overload adjustments should be set no higher than 100%unless necessary to stop nuisance tripping with <br /> measured amperage in all lines below maximum pump nameplate value. <br /> 2. If the pump rotates backwards as evidenced by low pressure and flow,correct rotation by reversing any two of <br /> the three power wires to the pump. <br /> Table 1. <br /> V-R Part No. Description <br /> 410648-001 GE Magnetic starter 120V coil CR306C10200AAAAA <br /> 410648-002 GE Magnetic starter 240V coil OR306010300AAAAA <br /> 410648-003 GE Magnetic starter 575V coil CR306C10400AAAAA <br /> Table 2. <br /> V-R Pump Model V-R Heater No. Description(Quantity of 3 Required) <br /> P75U17-3 AGP75817-3 410649-001 GE Amb.Comp.Heater-CR123C268A Trip Amps 2.59-x-10% <br /> P150U17-3 AGP150517-3 <br /> 410649-002 GE Amb.Comp.Heater-CR123C379A Trip Amps 4.20-f-10% <br /> X4P150U17 X4AGP150S17 <br /> P200U17-4 AGP200S17-4 410649-003 GE Amb.Comp.Heater-CR1 23C526A Trip Amps 5.63 f-10% <br /> P200J4-2MB 410649-004 GE Amb.Comp.Heater-CR123C778A Trip Amps 8.18-i-10% <br /> P300J17-3HB 410649-005 GE Amb.Comp.Heater-CR123C592A Trip Amps 6.24±10% <br /> P300J4-2HB 410649-006 GE Amb.Comp.Heater-CR1230113B Trip Amps 11.8±10% <br /> P500J17.3K 410649-007 GE Amb.Comp.Heater-CR123C955A Trip Amps 9.91 ±10% <br /> P500J4-2K 410649-008 GE Amb.Comp.Heater-CRY 23C1 BOB Trip Amps 19.4±10% <br /> P500J6-2K 410649-009 GE Amb.Comp.Heater-CR723C695A Trip Amps 7.35-E-10% <br /> 2 <br />
The URL can be used to link to this page
Your browser does not support the video tag.