My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2002-2015
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
CLAY
>
655
>
2300 - Underground Storage Tank Program
>
PR0231065
>
COMPLIANCE INFO_2002-2015
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/9/2022 2:10:00 PM
Creation date
6/23/2020 6:40:20 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2002-2015
RECORD_ID
PR0231065
PE
2361
FACILITY_ID
FA0003699
FACILITY_NAME
DSS COMPANY
STREET_NUMBER
655
Direction
W
STREET_NAME
CLAY
STREET_TYPE
ST
City
STOCKTON
Zip
95206
APN
14707110
CURRENT_STATUS
01
SITE_LOCATION
655 W CLAY ST
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231065_655 W CLAY_2002-2015.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
484
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN JOAQ �OUNTY ENVIRONMENTAL HEALT PARTMENT <br /> UNDERGROUND STORAGE TANK n`� , fM <br /> MONITORING PLAN -PAGE 1 ((�� - � <br /> JUN Mil. <br /> TYPE OF ACTION ❑ 1.NEW PLAN ❑ 2.CHANGE OF INFORMATION Moe. <br /> PLAN TYPE ® MONITORING IS IDENTICAL FOR ALL USTs AT THIS FACILITY. <br /> ECVVr-s i l <br /> (Check one item only) ❑ THIS PLAN COVERS ONLY THE FOLLOWING UST SYSTEMS) <br /> I ` FACILITY INFORMATION <br /> a. <br /> FACILITY ID#(Agency Use Only) <br /> M03. <br /> FACILITY NAME D.S.S. Tonnny <br /> Moa. Com, Mos. <br /> FACILITY SITE ADDRESS 655 West Clay St. Stockton <br /> II. EQiJIPNIENT TESTING" PREVENTIVE NTENANGE _` <br /> State law requires that testing,preventive maintenance,and calibration of monitoring equipment(e.g.,sensors,probes,line leak detectors etc.)be performed in Mob <br /> accordance with the equipment manufacturers'instructions,or annually,whichever is more frequent. Such work must be performed by qualified personnel. M07. <br /> MONITORING EQUIPMENT IS SERVICED ® 1.ANNUALLY ❑ 99.OTHER(Specify): <br /> III.:lYIp1�TITORING LOCATIONS <br /> This monitoring plan list include a Site Plan showing the general tank and piping layouts and the locations where monitoring is performed(i.e.,location of each sensor, <br /> mu <br /> line leak detector,monitoring system control panel,etc.). If you already have a diagram(e.g.,current UST Monitoring Site Plan from a Monitoring System Certification <br /> form,Hazardous Materials Business Plan map,etc.)which shows all required information,include it with this Dian. <br /> IV. TANK 1VIONITORING <br /> _ M10. <br /> ONITORING IS PERFORMED USING THE FOLLOWING METHOD(S):(Check all that apply) <br /> 1.CONTINUOUS ELECTRONIC MONITORING OF TANK ANNULAR(INTERSTITIAL)SPACE(S)OR SECONDARY CONTAINMENT VAULT(S) M11 <br /> SECONDARY CONTAINMENT IS: ® a.DRY [Ib.LIQUID FILLED El c.UNDER PRESSURE [3d.UNDER VACUUM Veeder - Root MODEL#: TTS - 300C M13. <br /> PANEL MANUFACTURER: <br /> LEAK SENSOR MANUFACTURER: Veerler - Rnnt <br /> M14 MODEL#(S): 794390 - 408 M15. <br /> ❑ 2.AUTOMATIC TANK GAUGING(ATG)SYSTEM USED TO MONITOR SINGLE WALL TANK(S)M16. MODEL <br /> Mt7 <br /> PANEL MANUFACTURER: MODEL#: <br /> M19. <br /> M18 MODEL#(S): <br /> IN-TANK PROBE MANUFACTURER: ryo. <br /> LEAK TEST FREQUENCY: ❑ a.CONTINUOUS ❑ b.DAILY/NIGHTLY ❑ c.WEEKLY <br /> M21. <br /> ❑ d.MONTHLY ❑ e.OTHER(Specify): M22 M23 <br /> PROGRAMMED TESTS: ❑ a.0.1 g.p.h. ❑ b.0.2 g.p.h. ❑ c.OTHER(Specify): Mea <br /> ❑ 3.INVENTORY RECONCILIATION ❑ a.MANUAL PER 23 CCR§2646 ❑ b.STATISTICAL PER 23 CCR§2646.1 <br /> ❑ 4.WEEKLY MANUAL TANK GAUGING(MTG)PER 23 CCR§2645 M25 <br /> TESTING PERIOD: ❑ a.36 HOURS ❑ b.60 HOURS <br /> ❑ 5.INTEGRITY TESTING PER 23 CCR§2643.1 M26. M227. <br /> TEST FREQUENCY: ❑ a.ANNUALLY ❑ b.BIENNIALLY ❑ c.OTHER(Specify): <br /> ❑ 6.VISUAL MONITORING DONE: ❑ a.DAILY ❑ b.WEEKLY(Requires agency approval) M28 <br /> ❑ <br /> 99.OTHER(Specify). <br /> V.;PIEE MONITORING M30. <br /> ONITORING IS PERFORMED USING THE FOLLOWING METHOD(S)(Check all that apply) <br /> 1.CONTINUOUS ELECTRONIC MONITORING OF PIPING SUMP(S)/TRENCH(ES)AND OTHER SECONDARY CONTAINMENT M31. <br /> SECONDARY CONTAINMENT IS: ❑ a.DRY ❑ b.LIQUID FILLED ❑ c.UNDER PRESSURE ❑ d.UNDER VACUUM M33. <br /> TTS 300( <br /> PANEL MANUFACTURER: V eder - Roo M32. MODEL#:M3a. M35. <br /> LEAK SENSOR MANUFACTURER: _ Veeder - Root MODEL 794380 - X09 <br /> � <br /> a.YES ❑ b.NO j''�6 <br /> WILL A PIPING LEAK ALARM TRIGGER AUTOMATIC PUMP(i.e.,TURBINE)SHUTDOWN. M37 <br /> WILL FAILURE/DISCONNECTION OF THE MONITORING SYSTEM TRIGGER AUTOMATIC PUMP SHUTDOWN? JR a.YES ❑ b.NO <br /> 2.MECHANICAL LINE LEAK DETECTOR (MLLD) THAT ROUTINELY PERFORMS 3.0 g.p.h. LEAK TESTS AND RESTRICTS OR SHUTS OFF <br /> PRODUCT FLOW WHEN A LEAK IS DETECTED M38 MODEL#(S): T D3000 1J)2001) M39. <br /> MLLD MANUFACTURER(s): VMT <br /> ❑ 3.ELECTRONIC LINE LEAK DETECTOR(ELLD)THAT ROUTINELY PERFORMS 3.0 g.p.h.LEAK TESTS Mol <br /> ELLD MANUFACTURER: M40. MODEL#: <br /> M42. <br /> PROGRAMMED LINE INTEGRITY TESTS: ❑ U <br /> a.MINIM MONTHLY 0.2 g.p.h. [3b.MINIMUM ANNUAL 0.1 g.p.h. <br /> � <br /> ❑ b.NO Mai. <br /> WILL ELLD DETECTION OF A PIPING LEAK TRIGGER AUTOMATIC PUMP SHUTDOWN? ❑ a.YES Mia <br /> WILL ELLD FAILURE/DISCONNECTION TRIGGER AUTOMATIC PUMP SHUTDOWN? Ela.YES [Ib.NO <br /> ❑ 4.INTEGRITY TESTINGMas. M46. <br /> TEST FREQUENCY: Ela.ANNUALLY ❑ b.EVERY 3 YEARS E] c.OTHER(Specify) <br /> ❑ C.MIN.2vIONTHLY&EACH TIME SYSTEM OPERATED" Mal. <br /> 5.V ISUAL MONITORING DONE: b.WEEKLY* <br /> ® a.DAILY . <br /> Requires agency approval "Allowed for monitoring of unburied emergency generator fuel piping only per HSC§25281.5(6)(3) <br /> ❑ 6.PIPING IS SUCTION PIPING MEETING ALL REQUIREMENTS FOR EXEMPTION FROM MONITORING PER 23 CCR§2636(a)(3) <br /> ❑ 7.NO PRODUCT OR REMOTE FILL PIPING IS CONNECTED TO THE UST(s) Mas <br /> ❑ 99.OTHER(Specify) 07/23/03 <br /> SJCEHD-d(07/03)-1/4 <br />
The URL can be used to link to this page
Your browser does not support the video tag.