My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2002-2015
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
CLAY
>
655
>
2300 - Underground Storage Tank Program
>
PR0231065
>
COMPLIANCE INFO_2002-2015
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/9/2022 2:10:00 PM
Creation date
6/23/2020 6:40:20 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2002-2015
RECORD_ID
PR0231065
PE
2361
FACILITY_ID
FA0003699
FACILITY_NAME
DSS COMPANY
STREET_NUMBER
655
Direction
W
STREET_NAME
CLAY
STREET_TYPE
ST
City
STOCKTON
Zip
95206
APN
14707110
CURRENT_STATUS
01
SITE_LOCATION
655 W CLAY ST
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231065_655 W CLAY_2002-2015.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
484
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Monitoring Plan =Page 2 Instru s <br /> Complete a separate UST Monitoring Plan for each UST monitoring system at the facility. This form must be submitted with your initial UST <br /> Operating Permit Application and within 30 days of changes in the information it contains. Please note that your local agency may require you to <br /> obtain approval prior to installing or modifying monitoring equipment. (Note: Numbering of these instructions follows the data element numbers on <br /> the form.) <br /> M50. DISPENSER MONITORING METHOD(S)—Check the appropriate box(es)in Section IV to identify all required methods used for monitoring <br /> the area(s)beneath the dispenser(s). If no dispensers are installed(e.g.,USTs supplying standby generators),check item VI-5. <br /> M51. PANEL MANUFACTURER—If item VI-1 is checked,enter the name of the manufacturer of the monitoring system control panel(console). <br /> If there is no control panel(e.g.,only an electrical relay box is installed)leave this space blank. <br /> M52. MODEL#—If item VI-1 is checked,enter the model number for the monitoring system control panel.If there is no control panel(e.g.,only an <br /> electrical relay box is installed)leave this space blank. <br /> M53. LEAK SENSOR MANUFACTURER—If item VI-1 is checked,enter the name of the manufacturer of the sensor(s). <br /> M54. MODEL#(S)—If item VI-1 is checked,enter the model number for each type of sensor installed.If additional space is needed,use Section IX. <br /> M55. WILL DETECTION OF A LEAK INTO UDC TRIGGER AUDIBLE AND VISUAL ALARMS?—If item VI-I is checked,check Yes or No. <br /> M56. WILL A UDC LEAK ALARM TRIGGER PUMP SHUTDOWN?—If item VI-1 is checked,check Yes or No. <br /> M57. WILL FAILURE/DISCONNECTION OF UDC MONITORING TRIGGER SHUTDOWN?—If item VI-1 is checked,check Yes or No. <br /> M58. ASSEMBLY MANUFACTURER—If item VI-2 is checked,enter the name of the manufacturer of the mechanical leak detection assembly. <br /> M59. MODEL#(S)—If item VI-2 is checked,enter the model number for each type of mechanical leak detection assembly installed. If additional <br /> space is needed,use Section IX. <br /> M60. VISUAL MONITORING DONE —If item VI-3 is checked,check the appropriate box to describe the frequency of visual monitoring. <br /> M61. SPECIFY—If item VI-99 is checked,enter a brief description of the other method(s)used to monitor the UDC. If additional space is needed, <br /> use Section IX. <br /> M70. ENHANCED LEAK DETECTION —Check the box if you have been notified by the State Water Resources Control Board(SWRCB)that the <br /> UST(s)covered by this plan is/are subject to Enhanced Leak Detection Requirements(i.e.,UST has any single-wall component and is located <br /> within 1,000 feet of a public drinking water well). <br /> M80. REFERENCE DOCUMENTS MAINTAINED AT FACILITY—Check the appropriate boxes to describe reference documents maintained at <br /> the facility. Note that items 1,2,and 3 must be kept at the facility. <br /> M81. SPECIFY— If item VIII-99 is checked, enter a brief description of the other document(s) maintained at the facility. If additional space is <br /> needed,use Section IX. <br /> M85. COMMENTS/ADDITIONAL INFORMATION — You may use this section to describe any additional UST system monitoring-related <br /> information(e.g.,additional information required by your local agency). If using Section IX as additional space for items required elsewhere <br /> in this plan,reference the item number(e.g.,"Item M54-Model 2468 and 3579 Leak Sensors"). <br /> OWNER/OPERATOR SIGNATURE—The owner/operator shall sign in the space provided. This signature certifies that the signer believes <br /> that all information submitted is true,accurate,and complete,and that the training program specified in Section VIII has been implemented.. <br /> M90. REPRESENTING—Check the appropriate box to indicate whether the signer is representing the UST owner or UST operator. <br /> M91. DATE—Enter the date the plan was signed. <br /> M92. OWNER/OPERATOR NAME—Print or type the name of the person signing the plan. <br /> M93. OWNER/OPERATOR TITLE—Enter the title of the person signing the plan. <br /> SJCEHD-d(07/03)-4/4 07/23/03 <br />
The URL can be used to link to this page
Your browser does not support the video tag.