Laserfiche WebLink
ORPFUNIEFIED PROGRAM CONSOLIDATED FN A <br /> UNDERGROUND STORAGE TANK <br /> OPERATING PERMIT APPLICATION-TANK INFORMATION(One form per UST) <br /> TYPE OF ACTION (Check one item only. For an UST permanent closure or removal,complete only this section and Sections I,II,III,IV,and IX below) 130 <br /> ❑ 1.NEW PERMIT ® 3.RENEWAL PERMIT ❑ 5.CHANGE OF INFORMATION <br /> ❑ 6.TEMPORARY UST CLOSURE ❑ 7.UST PERMANENT CLOSURE ON SITE ❑ 8.UST REMOVAL <br /> DATE UST PERMANENTLY CLOSED: 431 DATE EXISTING UST DISCOVERED: 430b <br /> I. FACILITY INFORMATION <br /> FACILITY ID#(Agency Use Only) 1 <br /> BUSINESS NAME(Same as FACILITY NAME or DBA-Doing Business As) <br /> Oss OSA khift R.ve <br /> BUSINESS SITE ADDRESS 103 CITY 104 <br /> G 5 ST To c.k To <br /> IL TANK DESCRIPTION <br /> TANK ID# 472 TANK MANUFACTURER 433 TANK CONFIGURATION: THIS TANK IS 434 <br /> -g+e 'e �/' g 9 �/ �p {/ W 1.A STAND-ALONE TANK <br /> /-S °V 60 1 '3 X1'2, X E 9/s E S [12.ONE IN A COMPARTMENTED UNIT. <br /> Complete one page for each wm arttnwt in the unit. <br /> DATE UST SYSTEM INSTALLED 435 TANK CAPACITY IN GALLONS 436 NUMBER OF COMPARTMENTS IN THE UNIT 437 <br /> / Zd 000 2 <br /> M.TANK USE AND CONTENTS <br /> TANK USE ED Ia.MOTOR VEHICLE FUELING ❑ lb.MARINA FUELING ❑ lc.AVIATION FUELING 439 <br /> ❑ 3.CHEMICAL PRODUCT STORAGE ❑ 4.HAZARDOUS WASTE(Includes Used Oil) ❑ 5.EMERGENCY GENERATOR FUEL[HSC§25281.5(c)] <br /> ❑ 6.OTHER GENERATOR FUEL ❑ 95.UNKNOWN ❑ 99.OTHER(Specify): 439a <br /> CONTENTS PETROLEUM: ❑ la.REGULAR UNLEADED ❑ ]c.MIDGRADE UNLEADED ❑ ]b.PREMIUM UNLEADED 440 <br /> 3.DIESEL ❑ 5.JET FUEL ❑ 6.AVIATION GAS <br /> ❑ 8.PETROLEUM BLEND FUEL ❑ 9.OTHER PETROLEUM (Specify): 440a <br /> NON-PETROLEUM:❑ 7.USED OIL ❑ 10.ETHANOL <br /> ❑ 11.OTHER NON-PETROLEUM(Specify): 440b <br /> IV. TANK CONSTRUCTION <br /> TYPE OF TANK ❑ 1.SINGLE WALL D1 2.DOUBLE WALL ❑ 95.UNKNOWN 443 <br /> PRIMARY CONTAINMENT ❑ 1.STEEL .!D 3.FIBERGLASS ❑ 6.INTERNAL BLADDER 444 <br /> ❑ 7.STEEL+INTERNAL LINING ❑ 95.UNKNOWN ❑ 99.OTHER (Specify): 444a <br /> SECONDARY CONTAINMENT ❑ L STEEL 3.FIBERGLASS ❑ 6.EXTERIOR MEMBRANE LINER ❑ 7.JACKETED 445 <br /> ❑ 90.NONE M 95.UNKNOWN [199.OTHER(Specify): 445a <br /> OVERFILL PREVENTION 1.AUDIBLE&VISUAL ALARMS ❑ 2.BALL FLOAT 24 3.FILL TUBE SHUT-OFF VALVE 452. <br /> ❑ 4.TANK MEETS REQUIREMENTS FOR EXEMPTION FROM OVERFILL PREVENTION EQUIPMENT <br /> V. PRODUCT/WASTE PIPING CONSTRUCTION <br /> PIPING CONSTRUCTION ❑1.SINGLE-WALLED 212.DOUBLE-WALLED ❑99.OTHER 460 <br /> SYSTEM TYPE 5l 1.PRESSURE ❑ 2.GRAVITY 3.CONVENTIONAL SUCTION ❑ 4.SAFE SUCTION[23 CCR§2636(a)(3)] 458 <br /> PRIMARY CONTAINMENT ❑ L STEEL 50 4.FIBERGLASS ❑ 8.FLEXIBLE ❑ 10.RIGID PLASTIC 464 <br /> ❑ 90.NONE ❑ 95.UNKNOWN ❑ 99.OTHER(Specify): 464a <br /> SECONDARY CONTAINMENT [1 1.STEEL R] 4.FIBERGLASS ❑ 8.FLEXIBLE ❑ 10.RIGID PLASTIC 464b <br /> ❑ 90.NONE ❑ 95.UNKNOWN ❑ 99.OTHER(Specify): 464c <br /> PIPING/TURBINE CONTAINMENT SUMP TYPE ® 1.SINGLE WALL ❑ 2.DOUBLE WALL ❑ 90.NONE 464d <br /> VI.VENT,VAPOR RECOVERY(VR)AND RISER/FILL PIPE PIPING CONSTRUCTION <br /> VENT PRIMARY CONTAINMENT ❑ 1.STEEL ® 4.FIBERGLASS ❑ 10.RIGID PLASTIC ❑ 90.NONE ❑ 99.OTHER(Specify) 464e <br /> 464el <br /> VENT SECONDARY CONTAINMENT ❑ 1.STEEL ❑ 4.FIBERGLASS ❑ 10.RIGID PLASTIC IO 90.NONE ❑ 99.OTHER(Specify) 4641 <br /> 464fl <br /> VR PRIMARY CONTAINMENT ❑ 1.STEEL ❑ 4.FIBERGLASS ❑ 10.RIGID PLASTIC 90.NONE ❑ 99.OTHER(Specify) 4648 <br /> 464 l <br /> VR SECONDARY CONTAINMENT ❑ L STEEL ❑ 4.FIBERGLASS ❑ W.RIGID PLASTIC 90.NONE ❑ 99.OTHER(Specify) 464h <br /> 464h1 <br /> VENT PIPING TRANSITION SUMP TYPE ❑ 1.SINGLE WALL ❑ 2.DOUBLE WALL 99 90.NONE 4641. <br /> RISER PRIMARY CONTAINMENT L STEEL ❑ 4.FIBERGLASS ❑ 10.RIGID PLASTIC 0 90.NONE 99.OTHER(Specify) 4641 <br /> 464j 1 <br /> RISER SECONDARY CONTAINMENT ❑ L STEEL ❑ 4.FIBERGLASS ❑ 10.RIGID PLASTIC (q 90.NONE 99.OTHER(Specify) 464k <br /> 464k1 <br /> FILL COMPONENTS INSTALLED IN 1.SPILL BUCKET ig 3.STRIKER PLATFJBOT 0M PROTECTOR 0 4.CONTAINMENT SUMP 451a-c <br /> VII.UNDER DISPENSER CONTAINMENT(UDC) <br /> CONSTRUCTION TYPE Ia 1.SINGLE WALL ❑ 2.DOUBLE WALL ❑ 3.NO DISPENSERS ❑ 90.NONE 469a <br /> CONSTRUCTION MATERIAL ❑ 1.STEEL ❑ 4.FIBERGLASS Q 10.RIGID PLASTIC ❑ 99.OTHER(Specify) 469b•e <br /> VIII. CORROSION PROTECTION <br /> STEEL COMPONENT PROTECTION ❑ 2.SACRIFICIAL ANODE(S) ❑ 4.IMPRESSED CURRENT ❑ 6.ISOLATION 448. <br /> LX. APPLICANT SIGNATURE : :yp <br /> CERTIFICATION: I certify that this UST system is compatible with the hazardous substance stored and that the information provide' be;*is true,accurate, <br /> and in full compliance with legal requirements. <br /> APPLICANT SIGNATURE DATE azo. <br /> --- <br /> APPLICANT NAME(print) n 471. APPLICANT TITLE 472. <br /> Lg2/2T o 4NtG <br /> UPCF UST-R-1/2 Rev.(1212007) <br />