My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_1995-2006
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
COUNTRY CLUB
>
2705
>
2300 - Underground Storage Tank Program
>
PR0231072
>
COMPLIANCE INFO_1995-2006
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/23/2023 3:13:14 PM
Creation date
6/23/2020 6:40:25 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1995-2006
RECORD_ID
PR0231072
PE
2361
FACILITY_ID
FA0002048
FACILITY_NAME
TESORO (SPEEDWAY) 68221
STREET_NUMBER
2705
STREET_NAME
COUNTRY CLUB
STREET_TYPE
BLVD
City
STOCKTON
Zip
95204
APN
12121008
CURRENT_STATUS
01
SITE_LOCATION
2705 COUNTRY CLUB BLVD
P_LOCATION
01
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231072_2705 COUNTRY CLUB_1995-2006.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
426
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Amk <br /> INDIVIDUAL TANK INFORMATION AND TEST RESULTS <br /> J'11110 <br /> TEST DATE: 05/11/05 8501 N MOPAC EXPRESSWAY,SUITE 400 WORK ORDER NUMBER: 2236317 <br /> AUSTIN,TEXAS 78759(512)451-6334 <br /> CLIENT: USA PETROLEUM SITE: USA 835 <br /> Tank ID: #1 2 Tank manifolded: NO Bottom to top fill in inches: 96.0 <br /> Product: DIESEL Vent manifolded: No Bottom to grade in inches: <br /> Capacity in gallons: 4,108 Vapor recovery manifolded: NO Fill pipe length in inches: <br /> Diameter in inches: 96.00 Overfill protection: YES Fill pipe diameter in inches: 4.0 <br /> Length in inches: 133 Overspill protection: YES Stage I vapor recovery: NONE <br /> Material: DW STEEL Installed: ATG Stage II vapor recovery: NONE <br /> CP installed on: <br /> COMMENTS <br /> PSI at tank bottom: New/passed Failed/replaced New/passed Failed/replaced <br /> Fluid level in inches: L.D.#1 L.D.#1 L.D.#2 L.D.#2 <br /> UFT/OFT: Make: VAPORLESS <br /> Fluid volume in gallons: Model: LD2000 <br /> Tank water level in inches: S/N: 47236 <br /> Test time: NOT Open time in sec: 4.00 <br /> Number of thermisters: TESTED Holding psi: 23 NOT <br /> Specific gravity: Resiliency cc: 160 TESTED <br /> Water table depth in inches: Test leak rate ml/m: 189.0 <br /> Determined by(method): Metering psi: 12 <br /> Leak rate in gph: Calib. leak in gph: 3.00 <br /> Result: Results: PASS <br /> COMMENTS COMMENTS <br /> Test time: <br /> Ullage volume: Material: DW FISERG <br /> Ullage pressure: Diameter(in): 2.0 <br /> Results: Length(ft): 120.0 <br /> Test psi: 50 <br /> DATA FOR UTS-4T ONLY: Bleedback cc: 0 <br /> Time of test 1: Test time(min): 30 <br /> Temperature: NOT Start time: 11:05 NOT NOT NOT <br /> Flow rate(cfh): TESTED End time: 11:35 TESTED TESTED TESTED <br /> Time of test 2: Final gph: 0.000 <br /> Temperature: Result: PASS <br /> Flow rate(cfh): Pump type: PRESSURE <br /> Time of test 3: Pump make: RED JACKET <br /> Temperature: <br /> Flow rate(cfh): Impact Valves Operational: YES <br /> COMMENTS COMMENTS <br /> Printed 05/16/2005 08:35 SBOWERS <br />
The URL can be used to link to this page
Your browser does not support the video tag.