Laserfiche WebLink
Method Description <br />The process is described in the following steps: <br />•- Preparation <br />• Probe Array Installation <br />• Inoculation <br />• Sample Collection <br />• Sample Analysis <br />• Leak Location <br />• Reporting <br />Preparation <br />Upon arrival at the site, the Tracer crew reviews the tank information that has been made <br />available and uses this information to plan the installation of the sampling probe array. If <br />as built plans or site plans have not been made available the crew inspects all accessible <br />portions of the system to learn as much as possible about the location of all UST system <br />components. <br />If the site is under remediation, soil vapor extraction systems, air sparging systems and <br />bio -venting systems must be turned off during the test. <br />Probe Array Installation <br />Sampling probes consisting of %" schedule 40 PVC are installed within ten horizontal <br />feet of all possible leak locations (each probe has a twenty foot diameter sphere of <br />influence). Probes are installed by coring a hole in the pavement and inserting a sampling <br />probe into the excavation zone of the tank or pipe using soft excavation techniques. The <br />top of each probe is fitted with a PVC sampling cap that will be used later for soil vapor <br />extraction. <br />Tanks <br />Tank probes are installed along the outer long -side of each tank, generally at a depth <br />within two feet of the tank bottom (or just above the water table if applicable). Each tank <br />will have at least two probes per long side (except for tanks 1,000 gallons or less). Tanks <br />within the same tank pit may share probes placed between tanks. Additional shallow <br />probes (generally one foot in depth) may also be installed near appurtenances along the <br />tank ridge, but these are not required, but highly recommended in order to assist in <br />identifying the source of potential vapor leaks. In situations where tank pits do not <br />contain engineered backfill (pea -gravel), the sampling probes are installed within five <br />horizontal feet of all possible leak locations. <br />Please note the details provided in this Work Plan regarding the test specifications, including but not limited to probe placement are <br />considered proprietary confidential information and are considered the property of Tracer Research Corporation and are patent <br />protected and shall only be used for technology evaluation purposes.. <br />