COMPLIANCE INFO_1995-2006
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
COUNTRY CLUB
>
2705
>
2300 - Underground Storage Tank Program
>
PR0231072
>
COMPLIANCE INFO_1995-2006
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/23/2023 3:13:14 PM
Creation date
6/23/2020 6:40:25 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1995-2006
RECORD_ID
PR0231072
PE
2361
FACILITY_ID
FA0002048
FACILITY_NAME
TESORO (SPEEDWAY) 68221
STREET_NUMBER
2705
STREET_NAME
COUNTRY CLUB
STREET_TYPE
BLVD
City
STOCKTON
Zip
95204
APN
12121008
CURRENT_STATUS
01
SITE_LOCATION
2705 COUNTRY CLUB BLVD
P_LOCATION
01
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231072_2705 COUNTRY CLUB_1995-2006.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
426
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
COUNTRY CLUB BOULEVARD <br />PETROLEUM LAYOUT <br />9CAl.E: i" - 10' (PLOTTED TO FIT SHEET SIZE) <br />• 0 <br />PETROLEUM PROJECT DESCRIPTION <br />INSTALL NEW PIPING, ISLANDS, DISPENSERS, AS SHOWN. <br />GASOLINE DISPENSERS ARE TO BE FIXED BLENDER, MULTI -PRODUCT. <br />STORED PRODUCTS LIMITED TO NIGH t LOW OCTANE UNLEADED GASOLINE 4 DIESEL <br />KEYNOTES, SCOPE <br />1. 3 - NEW 2"0 TANK PENT RISERS. INSTALL NEW SWING JOINT$ AT BASE AND <br />CONNECT TO NEW VENT LINES. <br />2. 2"0 FIBERGLASS TANK VENT LINES SLOPED BACK TO EACH TANG AT 1/8" PER <br />FOOT, MIN. <br />3. GILBARCO DUAL -DIESEL DISPENSER ON BRAVO CONTAINMENT/SHEAR VALVE SYSTEM. <br />4. GILBARCO MPD FIXED 15LENDER DISPENSERS (CNE HOSE PER SIDE) CN <br />BRAVO BOX CONTAINMENT/SHEAR VALVE SYSTEMS. TYPICAL OF 4. <br />5. 34 FIBERGLASS PHASE 11 VAPOR RECOVERY PIPING FROM DISPENSERS TO <br />TANKS. SLOPE 1/8"/FOOT MINIMUM BACK TO TANK (24 OK TO SINGLE MPDJ <br />6. 2"0 PRODUCT PIPE W/ 3"0 SECONDARY CONTAINMENT, TYPICAL ALL PRODUCTS. <br />SLOPE BACK TO TAMC" AT 1/8" PER FOOT MIN. <br />W 1. NEW UNDER3ROUND FUEL STORAGE TANKS. 1-120= GALLON UNLD. REG, <br />1-124$00 SPLIT 8000 UNLD. SUPER AND .4,000 DIESEL <br />8. TANK ANNULAR SPACE W/ TANK PROBE AND W.T. MANWAY. TYP. OF 2. <br />Z S. TANK FILL W/ 5 GALLON FILL CONTAINMENT. TYPICAL OF 3. <br />W 10. PHASE I (DRYBRF.AK) VAPOR PECO/ERY, W/ 12" MIN. MANHOLE. TYP, OF 2. <br />' 11. MAGNETOSTRICTIVE TANK GAUGE W/IN W.T. MANWAY. TYPICAL OF 3. <br />12. 1!': Kp. SUBMERSIBLE TURBINE PUMP (STP) LL/IN 42"0 F.R.P. SUMP W/ FLOAT <br />SWITCH SUMP PROBE, LID AND 36" MANWIAY. TYPICAL OF 3. <br />13. 8" THICK CONCRETE TANK SLAB W/ -4 REBAR AT 18" O.C. BOTH WAYS. <br />W 14. BACKFILL TRENCHES WITH PEA GRAVEL TO LEVEL. REQUIRED <br />FOR NEW SLURRY COrER AND PAVING BASE. PROVIDE SLURRY <br />Q CONCRETE 4" THICK (MIN.) OVER PEA GRAVEL <br />15. NEW 6" THICK CONCRETE DRIVE SLAB W/ -4 REBAR AT 24" O.G. BOTH WAYS, <br />OVER 6" AGGREGATE BASE. <br />M <br />16, MONITOR CONTROLS AND ALARM, W/ VISUAL 4 AUDIBLE ACCESSIBILITY. �cl� <br />ii n. NEWESA. W/ ASIBLE SIGN, SEE GENERAL NOTES. <br />18. NEW AIRAWATER UNIT. <br />19. NEW AC. PAVING, PER CI',lL DRAWINGS. <br />20. NEW CANOPY, 58' i 48', BY OTHERS. w 341." <br />GENERAL NOTES 0F_ A S <br />PROVIDE AT LEAST ONE PORTABLE FIRE G <br />EXTINGUISHER W/ A MINIMUM RATIN <br />OF 2-A"O-B:C WITHIN SEVENTY-FIVE (15) FEET OF ANY PUMP, DISPENSER <br />OR FILL -PIPE OPENING. THIS EXTINGUISHER TO BE AFFIXED TO A LOCATION /�� <br />ON A MOUNTING BRACKET OR IN A FIRE EXTINGUISHER CABINET. 1 73908) ` <br />rf <br />A CLEARLY LABELED, MANUALLY OPERATED PUMP MASTER SWITCH SHALL <br />BE PROVIDED IN AN APPROVED LOCATION W/IN 15 FEET, BUT NOT NEARER <br />THAN 25 FEET TO, ANY DISPENSER WHERE SUCH MASTER SWITCH IS NOT <br />VISIBLE FROM ALL DISPENSERS, THE LOCATION THEREOF SHALL BE INDICATED <br />BY APPROVED SIGNS. SIGNS IDENTIFYING THE PUMP MASTER SWITCH SHALL <br />BE LABELED "EMERGENCY FUEL SHUTDOWN DEVICE". THE MASTER SWITCH ON <br />ALL INDIVIDUAL PUMP CIRCUIT SWITCHES SHALL BE SET IN THE "OFF" POSITION <br />BEFORE CLOSING THE STATION FOR BUSINESS AT ANT TIME. (UFC 520153) <br />UNFINISHED ABOVEGROUND METALS SHALL BE CLEANED, PRIMED, AND PAINTED <br />UTAH SUITABLE MATERIALS. COORDINATE COLORS WITH OWNER <br />ALL MATERIALS AND EQUIPMENT SHALL BE INSTALLED AND TESTED PER <br />MANUFACTURER'S INSTRUCTIONS, APPLICABLE CODES AND STANDARDS, <br />THE PLANS AND SPECIFICATIONS, AND LOCAL AGENCY REQUIREMENTS. <br />GOVERNING CODES PETROLEUM SHEET INDEX <br />GOVERNING CODES AND STANDARDS INCLUDE, BUT SHALL NOT BE PET -I PETROLEUM SITE PLAN <br />LIMITED TO, THE STANDARDS OF THE FOLLOWING: KEYNOTES SCOPE <br />UNIFORM FIRE CODE DE UNIPET-2 GASOLINE TANK SECTION, SLAB <br />RATIONAL <br />BUILDINGELECTRIC <br />CODE (UDC) PET -3 SPLIT TANK SECTION <br />NATIONAL ELECTRIC GORE (NEC) <br />NATIONAL FIRE PROTECTION AGENCY (MPPA) PET -4 PETROLEUM DETAILS <br />CALIFORNIA UNDERGROUND TANK STORAGE REGULATIONS <br />LOCAL ORDINANCES <br />EXXON <br />TIGER MART <br />2105 COUNTRY CLUB <br />15MLEVAIRD <br />STOCKTON, CA <br />ALTON <br />NGINEERING" INC. <br />PD. BOX 1025 <br />843 RISKE LANE <br />WEST SACRAMENTO, CA 95691 <br />(916) 312-1888 <br />FAX 373-1112 <br />r <br />COPYRIGHT ® 1995 <br />'GRATIN BY <br />MEL <br />0.1101 BY <br />RJH <br />DATE i <br />10 OCT 95 <br />SCALE <br />P-10' <br />JOB NO. <br />25860 <br />SHEET TITLE <br />PETROLEUM <br />LAYOUT <br />PET -1 <br />CIF 4 SHEETS <br />
The URL can be used to link to this page
Your browser does not support the video tag.