Laserfiche WebLink
F2 <br />IWO <br />r�, ,> /o - Z 6 -PNS By <br />'do7s beef r ���t LL E V <br />COUNT ' Y 1 + r approve Thyumi3siorT <br />of dev;=� I'on of requirements of State laws or <br />E r <br />®calOrdinances. <br />PETROLEUM LAYOUT <br />SCALE: 1" - 10' (PLOTTED <br />SIZE) <br />0 5 tD 20 30 40 50 <br />A R D <br />z� <br />I— <br />PETROLEUM PROJECT DESCRIPTION <br />INSTALL NEW PIPING, ISLANDS, DISPENSERS, AS SHOWN. <br />GASOLINE DISPENSERS ARE TO BE FIXED BLENDER, MULTI -PRODUCT. <br />STORED PRODUCTS LIMITED TO HIGH 1 LOW OCTANE UNLEADED GASOLINE t DIESEL <br />KEYNOTES,SCOPE <br />I. 3 - NEW 2'♦ TANK VENT RISERS. INSTALL NEW SWING JOINTS AT BASE AND <br />CONNECT TO NEW YEW LINES. <br />2. 2"e FIBERGLASS TANK VENT LINES SLOPED BACK TO EACH TANK AT I/8" PER <br />FOOT, MIN. <br />3. GILBARCO DUAL -DIESEL DISPENSER ON BRAVO CONTAINMENT/SHEAR VALVE SYSTEM. <br />4. GILBARCO MPD FIXED BLENDER DISPENSERS (ONE HOSE PER SIDE) ON <br />BRAVO BOX CONTAINMENT/SHEAR VALVE SYSTEMS. TYPICAL OF 4. <br />5. 3"e FIBERGLASS PHASE II VAPOR RECOVERY PIPING FROM DISPENSERS TO <br />TANKS. SLOPE I/8'/FOOT MINIMUM BACK TO TAMC (24 OK TO SINGLE MPD ) <br />6. 2"e PRODUCT PIPE W/ 34 SECONDARY CONTAINMENT, TYPICAL ALL PRODUCTS. <br />SLOPE BACK TO TANKS AT 1/8" PER FOOT MIN. <br />1. NEW UNDERGROUND FUEL STORAGE TANGS. 1-12,000 GALLON UNLD. REG, <br />1-12,000 SPLIT 6,000 UNLD. SUPER .AND 4000 DIESEL. <br />9. TANK ANNULAR SPACE W/ TANG PROBE AND W.T. MANWAY. TYP. OF 2. <br />Z 9. TANK FILL W/ 5 GALLON FILL CONTAINMENT. TYPICAL OF 3. <br />W 10. PHASE I (DRYBREA ) VAPOR RECOVERY, W/ 12" MIN. MANHOLE. TYP. OF 2. <br />> 11. MAGNETOSTRICTIVE TANK GAUGE WAN W.T. MANWAY. TYPICAL OF 3. <br />Q 12. 1'.'= hp. SUOMERS15LE TURBINE PUMP (STP) W/IN 42"e F.R.P. SUMP W/ FLOAT <br />SWITCH SUMP PROBE, LID .AND 36" MANWAY. TYPICAL OF 3. <br />13. 8" THICK CONCRETE TANK SLAB W/ #4 REBAR AT 18" O.C. BOTH WAYS. <br />W 14. BACKFILL TRENCHES WITH PEA GRAVEL TO LEVEL REQUIRED <br />FOR NEW SLURRY COVER AND PAVING BASE. PROVIDE SLURRY <br />Q CONCRETE 4" THICK (MNJ OVER PEA GRAVEL. <br />15. NEW 6" THICK CONCRETE DRIVE SLAB W/ #4 RESAR AT 24' O.C. BOTH WAYS, <br />} O`/ER 6" AGGREGATE BASE. <br />cc 16. MONITOR CONTROLS AND ALARM, W/ VISUAL 4 AUDIBLE ACCESSIBILITY A <br />M. NEW E.S.O. W/ '/18IBLE SIGN, SEE GENERAL NOTES. <br />18. NEW AIRNIATER UNIT, jGy 4t <br />19. NEW AC, PAVING, PER CIVIL DRAWINGS. <br />20. NEW CANOPY, 58' x 48', BY OTHERS. <br />Nd C <br />21. PRIOR LOCATION, USTs 11410{, 1481, 10610 ALREADY REMOVED. IiEN- . A�) <br />GENERAL NOTES 0 CA <br />Lr) <br />LU w <br />PROVIDE AT LEAST ONE PORTABLE FIRE EXTINGUISHER W/ A MINIMUM RATING`/ <br />DATE <br />=U <br />OF 2-A$O-B,C WITHIN SEVENTY-FIVE 05) FEET OF ANY PUMP, DISPENER <br />S <br />Q7 <br />Q <br />OR FILL -PIPE OPENING. HEXTINGUISHER AFFIXED r <br />ON A MOUNTING BRACKET OR N A FIRA(UFO <br />C <br />XTTINGUISHER CABNET. 19.908) <br />w CO <br />A CLEARLY LABELED, MANUALLY OPERATED PUMP MASTER SWITCH SHALL <br />-1 <br />SE PROVIDED IN AN APPROVED LOCATION WAN 15 FEET, BUT NOT NEARER <br />Z <br />THAN 25 FEET TO, ANY DISPENSER WHERE SUCH MASTER SWITCH IS NOT <br />VISIBLE FROM ALL DISPENSERS, THE LOCATION THEREOF SHALL SE INDICATED <br />? <br />r— <br />BY APPROVED SIGNS. SIGNS IDENTIFYING THE PUMP MASTER SWITCH SHALL <br />BE LABELED 'EMERGENCY FUEL SHUTDOWN DEVICE'. THE MASTER SWITCH ON <br />ALL INDIVIDUAL PUMP CIRCUIT SWITCHES SHALL BE SET IN THE 'OFF' POSITION <br />BEFORE CLOSING THE STATION FOR BUSINESS AT ANY TIME. (UFC 520133) <br />UNFINISHED ABOVEGROUND METALS SHALL BE CLEANED, PRIMED, AND PAINTED <br />WITH SUITABLE MATERIALS. COORDINATE COLORS WITH CWMR, <br />ALL MATERIALS .AND EQUIPMENT SHALL BE INSTALLED AND TESTED PER <br />MANUFACTURER'S INSTRUCTIONS, APPLICABLE CODES AND STANDARDS, <br />THE PLANS AND SPECIFICATIONS, AND LOCAL AGENCY REQUIREMENTS. <br />GOVERNING CODES PETROLEUM SHEET INDEX <br />GOVERNING CODES ARID STANDARDS INCLUDE, BUT SHALL NOT BE PET -1 PETROLEUM SITE PLAN <br />LIMITED TO, THE STANDARDS OF THE FOLLOWING, KEYNOTES, SCOPE <br />UNIFORM FIRE CODE (UFC) PET -2 GASOLINE TANK SECTION, SLAB <br />UNIFORM BUILDING GORE (UBC) <br />NATIONAL ELECTRIC CODE (NEC) PET -3 SPLIT TANK SECTION <br />NATIONAL, FIRE PROTECTION AGENCY (N+PA) PET -4 PETROLEUM DETAILS <br />CALIFORNIA UNDERGROUND TAMC STORAGE REGULATIONS <br />LOCAL ORDINANCES <br />EXISTING MONTIORNG WELL, <br />MW PROTECT DURING CONSTRUCTION <br />EXISTING VAPOR EXTRACTION WELL, <br />E PROTECT DURING CONSTRUCTION, <br />EXXON <br />TILER MART <br />2105 COUNTRY CLUB <br />BOULEVARD <br />STOCKTON, CA <br />ti <br />W ALTON <br />NGINEEFtING, INC. <br />PD. BOX 1025 <br />843 RISKS LANE <br />WEST SACRAMENTO, CA 95691 <br />(916) 312 -OW <br />FAX 313-1112 <br />TEMPORNM4rANO0-09M02* Ab <br />W omm w rmR, mm M <br />Ffflr2EY CN "TCM *41ltlY MW <br />AV MALL NR M UND NOR AM MWM <br />0"M TNM TNON NOR saw TW NINA <br />� MlRM CM NIAM. TNM ONMpO <br />MALL NOT= NlROOII m OR Imm <br />N * <br />"WT4 W rim Warm— amwcP <br />OLLTaM ■*tuft NO. <br />COPYRIGNT 0 1995 <br />DRAM BY MEL <br />CHM' SY ; <br />RJH <br />DATE <br />10 OCT w <br />SCALE <br />JOB NO. <br />25860 <br />REVISIONS <br />DATE REV! DEGCMPTION B <br />"ONITORING M <br />LLELLS, USTs <br />I <br />I <br />I <br />SHEET TITLE <br />PETROLEUM <br />LAYOUT <br />PET -1 <br />OF 4 SHEETS <br />