My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_1995-2006
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
COUNTRY CLUB
>
2705
>
2300 - Underground Storage Tank Program
>
PR0231072
>
COMPLIANCE INFO_1995-2006
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/23/2023 3:13:14 PM
Creation date
6/23/2020 6:40:25 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1995-2006
RECORD_ID
PR0231072
PE
2361
FACILITY_ID
FA0002048
FACILITY_NAME
TESORO (SPEEDWAY) 68221
STREET_NUMBER
2705
STREET_NAME
COUNTRY CLUB
STREET_TYPE
BLVD
City
STOCKTON
Zip
95204
APN
12121008
CURRENT_STATUS
01
SITE_LOCATION
2705 COUNTRY CLUB BLVD
P_LOCATION
01
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231072_2705 COUNTRY CLUB_1995-2006.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
426
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• • <br /> Integrated solution for centralized , <br /> single system site monitoring. <br /> Standard Models <br /> Console Form Number: 848290-022 <br /> Description: TLS-350 Plus monitoring console with integral printer <br /> Console Form Number: 848290-002 <br /> Description: TLS-350 Plus monitoring console without integral printer <br /> Console Form Number: 848291-021 <br /> Description: TLS-350 Plus PC version without printer,keyboard or display <br /> TLS-350 Plus Interface Modules <br /> The TLS-350 Plus monitoring console contains three compartments in which individual interface modules can be installed. Interface modules <br /> may be factory-installed in the console upon initial ordering,or ordered separately as spare modules to expand an existing system. <br /> Form No. <br /> Factory <br /> Installed <br /> Modules Description Feature Compatibility(where applicable) <br /> LOW-POWER COMPARTMENT(Limit eight per console,unless otherwise noted) <br /> 329356-002 Four-Input Probe Interface Module(Maximum three per Series 8473 0.1 GPH Magnetostrictive Probe <br /> console.Includes terminal connector for one ground <br /> temperature thermistor for the volumetric line leak detector). <br /> 329358-001 Eight-Input Interstitial/Liquid Sensor Series 7943 Interstitial Sensor for Fiberglass Tanks and <br /> Interstitial Sensor for Steel Tanks <br /> Series 7943 Piping Sump Sensor <br /> Series 7943 Hydrostatic Sensor <br /> 329357-001 Five-Input Vapor Sensor Interface Module Series 7943 Vapor Sensor <br /> 329399-001 Five-Input Groundwater Sensor Module 4SITE Series 7943 Groundwater Sensor <br /> 329956-001 Eight-Input Type A Sensor Interface Module 4SITE Series 7943 Discriminating Interstitial Sensor <br /> 329950-001 Six-Input Type B Sensor Interface Module 4SITE Series 7943 Discriminating Dispenser <br /> 330843-001 Six-Input Pressurized Line Leak Interface Series 8484 Pressurized Line Leak Detection System <br /> Module(One per console) Requires TLS-350 Plus version 7.0 or higher software <br /> HIGH-POWER COMPARTMENT(Limit eight per console,unless otherwise noted) <br /> 329359-001 Four-Relay Output Interface Module <br /> 329360-001 Two-Input/Two-Relay Output Interface Module <br /> 329999-001 Pump Sense Interface Module Accepts up to four inputs. <br /> 330374-001 Three-Output Pressurized Line Leak Series 8484 Pressurized Line Leak Detection System <br /> Controller Interface Module(Two per console) Requires TLS-350 Plus version 7.0 or higher software <br /> COMMUNICATIONS COMPARTMENT(Limit three per console,unless otherwise noted) <br /> 330149-002 SiteFax Interface Module Allows hookup to most remote facsimile,modem or teletype <br /> equipment.Requires TLS-350 Plus version 3.0 or higher software. <br /> 330586-001 RS-485/232 Dual Port Communications Module(Slot 4 only) <br /> 330148-001 RS-232 Interface Module with Auxiliary Port Provides two 25-pin D-connectors for data transmission to <br /> P.O.S.terminal,printing device or computer <br /> 329362-001 RS-232 Interface Module Provides a 25-pin D-connector for data transmission to <br /> P.O.S.terminal,printing device,or computer <br /> 330000-001 Remote Printer Interface Module Provides a 25-pin D-connector for data transmission <br /> to a remote serial printer <br /> 330883-001 WPLLD Communications Module <br /> (Maximum one per console) <br /> 330020-425 Ethernet-TCP/IP Communications module Provides connectivity to local and wide area networks(LAN/WANS) <br /> Specifications <br /> Operating Temperature Range 32°F to 118°F(0°C to 45°C) For more information call <br /> Storage Temperature Range 15°F to 118°F(10°C to 45°C) 1-888-561-7942 <br /> —�O� Q 2003 Veeder-Root Company - 125 Powder Forest Drive - Simsbury,CT 06070 - USA <br /> VEEMRTelephone:860-651-2700 - Fax:860-651-2719 - www.veeder.com <br /> VR 13679 P/N 0576047-022 Rev.D VRLP 8/2003 Printed in USA <br />
The URL can be used to link to this page
Your browser does not support the video tag.