My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_1998-2002
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
D
>
DA VINCI
>
4627
>
2300 - Underground Storage Tank Program
>
PR0231074
>
COMPLIANCE INFO_1998-2002
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/1/2023 9:51:39 AM
Creation date
6/23/2020 6:40:56 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1998-2002
RECORD_ID
PR0231074
PE
2361
FACILITY_ID
FA0002541
FACILITY_NAME
7-ELEVEN INC #20632
STREET_NUMBER
4627
STREET_NAME
DA VINCI
STREET_TYPE
DR
City
STOCKTON
Zip
95207
APN
11002003
CURRENT_STATUS
01
SITE_LOCATION
4627 DA VINCI DR
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231074_4627 DA VINCI_1998-2002.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
341
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
'r. <br /> NOW <br /> UNIFIED PROGRAM CONSOLIDATED FORM <br /> TANKS <br /> UNDERGROUND STORAGE TANKS-TANK PAGE 1 <br /> (two pages per tank) <br /> Page _ of <br /> TYPE OF ACTION ❑1.NEW SITE PERMIT ❑ 4. AMENDED PERMIT ❑ 5. CHANGE OF INFORMATION) ❑ G. TEMPORARY SITE CLOSURE <br /> (Check one item only) <br /> ❑ 7. PERMANENTLY CLOSED ON SITE <br /> ❑3.RENEWAL PERMIT (Specify reason-for local use only) (Specify change•for local use only) ❑ 8. TANK REMOVED 430 <br /> BUSINESS NA (Same as FACILITY NAME or DBA-Doing Business As) FACILITY ID# 1 <br /> f' <br /> LOCATION WITHIN SITE(Optionaq 431 <br /> 467-7 <br /> �- <br /> I.TANK DESCRIPTION <br /> TANK ID# TANK MANUFACTURER <br /> _ �• <.., COMPARTMENTALIZED TANK ❑ Yes ❑ No <br /> If'Yes',complete one page for each compartment. <br /> DATE INSTALLED(YEAR/MO) TANK CAPACITY IN GALLONS NUMBER OF COMPARTMENTS <br /> ADDITIONAL DESCRIPTION(Forlocal use only) <br /> II.TANK CONTENTS <br /> TANK USE 432 PETROLEUM TYPE <br /> ❑ 1. MOTOR VEHICLE FUEL ❑Ia. REGULAR UNLEADED ❑ 2. LEADED C15. JET FUEL <br /> (If marked,complete Petroleum Type) El 1b. PREMIUM UNLEADED ❑ 3. DIESEL ❑ 6. AVIATION FUEL <br /> ❑ 2. NON-FUEL PETROLEUM ❑1c. MIDGRADE UNLEADED ❑ 4. GASOHOL ❑99. OTHER <br /> ❑ 3. CHEMICAL PRODUCT <br /> 4. HAZARDOUS WASTE(Includes COMMON NAME(from Hazardous Materials Inventory page) CAS#(from Hazardous Materials Inventory page) <br /> ❑ <br /> Used 010 <br /> El 95 <br /> NOWN <br /> 111.TANK CONSTRUCTION <br /> TYPE OF TANK ❑ 1. SINGLE WALL ❑ 3. SINGLE WALL WITH ❑ 5. SINGLE WALL WITH INTERNAL BLADDER SYSTEM <br /> (Check one item only) ❑ 2. DOUBLE WALL EXTERIOR MEMBRANE LINER ❑95. UNKNOWN <br /> '❑ 4. SINGLE WALL IN A VAULT ❑99 OTHER <br /> TANK MATERIAL.primary tank ❑ 1 BARE STEEL ❑ 3. FIBERGLASS/PLASTIC ❑ S. CONCRETE 1195. UNKNOWN <br /> (Check one item only) ❑ 2. STAINLESS STEEL ❑4. STEEL CLAD W/FIBERGLASS ❑ 8. FRP COMPATIBLE W/100%METHANOL ❑99. OTHER <br /> REINFORCED PLASTIC(FRP) <br /> TANK MATERIAL-secondary tank ❑ 1 BARE STEEL ❑ 3. FIBERGLASS/PLASTIC ❑ 6. FRP COMPATIBLE WI100%METHANOL ❑95. UNKNOWN <br /> (Check one item only) ❑ 2. STAINLESS STEEL ❑ 4. STEEL CLAD W/FIBERGLASS ❑ 9. FRP NON-CORRODIBLE JACKET ❑99. OTHER <br /> REINFORCED PLASTIC(FRP) ❑10. COATED STEEL <br /> ❑ 5. CONCRETE <br /> TANK INTERIOR LINING ❑ 1. RUBBER LINED ❑ 3. EPDXY LINING ❑ 5. GLASS LINING 1195. UNKNOWN433 DATE INSTALLED <br /> OR COATING <br /> ❑ 2. ALKYD LINING ❑ 4. PHENOLIC LINING ❑ 6. UNLINED 1199. OTHER <br /> (Check one Rem only) (For local use only) <br /> OTHER CORROSIONC31. MANUFACTURED CATHODIC ❑ 3. FIBERGLASS REINFORCED PLASTIC ❑95. UNKNOWN 434 DATE INSTALLED <br /> PROTECTION IF APPLICABLE <br /> PROTECTION ❑ 4. IMPRESSED CURRENT ❑99. OTHER <br /> (Check one item only) ❑ 2. SACRIFICIAL ANODE (For local use only) <br /> SPILL AND OVERFILL YEAR INSTALLED TYPE(For local use only) OVERFILL PROTECTION EQUIPMENT:YEAR INSTALLED <br /> (Check all that appal ❑ 1. SPILL CONTAINMENT ❑ 1. ALARM ❑ 3. FILL TU13E SHUT OFF VALVE <br /> ❑ 2. DROP TUBE ❑ 2. BALL FLOAT ❑ 4. EXEMPT <br /> ❑ 3. STRIKER PLATE <br /> IV.TANK LEAK DETECTION <br /> IF SINGLE WALL TANK Check all that apply): IF DOUBLE WALL TANK OR TANK WITH BLADDER(Check one item only): <br /> ❑ 1, VISUAL(EXPOSED PORTION ONLY) ❑ 5. MANUAL TANK GAUGING(MTG) ❑ 1. VISUAL(SINGLE WALL IN VAULT ONLY) <br /> ❑ 2. AUTOMATIC TANK GAUGING(ATG) ❑ 6. VADOSE ZONE ❑ 2. CONTINUOUS INTERSTITIAL MONITORING <br /> ❑ 3. CONTINUOUS ATG - ❑ 7. GROUNDWATER ❑ 3. MANUAL MONITORING <br /> ❑ 4. STATISTICAL INVENTORY RECONCILIATION(SIR)+ ❑ 8. TANK TESTING <br /> BIENNIAL TANK TESTING ❑99. OTHER <br /> V.TANK CLOSURE INFORMATION/PERMANENT CLOSURE IN PLACE <br /> ESTIMATED DATE LAST USED(YR/MO/DAY) ESTIMATED QUANTITY OF SUBSTANCE REMAINING 435 1 TANK FILLED WITH INERT MATERIAL? <br /> gallons ❑ 11 No <br /> Yes <br /> CUPAFORM(4/99) �( z l�� Formerly SWRCB Form B <br />
The URL can be used to link to this page
Your browser does not support the video tag.