My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2009-2012
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
D
>
DA VINCI
>
4627
>
2300 - Underground Storage Tank Program
>
PR0231074
>
COMPLIANCE INFO_2009-2012
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/1/2023 11:20:58 AM
Creation date
6/23/2020 6:41:02 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2009-2012
RECORD_ID
PR0231074
PE
2361
FACILITY_ID
FA0002541
FACILITY_NAME
7-ELEVEN INC #20632
STREET_NUMBER
4627
STREET_NAME
DA VINCI
STREET_TYPE
DR
City
STOCKTON
Zip
95207
APN
11002003
CURRENT_STATUS
01
SITE_LOCATION
4627 DA VINCI DR
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231074_4627 DA VINCI_2009-2012.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
434
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
File MH29667 Page T1-2 of 2 Issued: 2005 09- 08 <br /> SIMULATED USE RESISTANCE TO FLUIDS TEST (FIBERGLASS REINFORCED PLASTIC" SUMP <br /> MATERIALS) : <br /> METHOD <br /> one sample assembly as described in Item B was placed in a container <br /> filled with each of the fluids Listed below such that the fittings inside the <br /> container were completely covered with the fluids. The samples and fluids <br /> were maintained at a temperature of 100OF throughout the exposure. Following <br /> 30 days in this condition, the containers were subjected to an internal <br /> pressure of 4.5 prig (based on a maximum sump depth of 10.3 ft..) for a period <br /> of at least 5 min. while the samples were examined for evidence of leakage. <br /> 100% Methanol <br /> 50% Methanol/50% ASTM Reference Fuel C <br /> 15% Ethanol/85% ASTM Reference Fuel C <br /> 10% Ethanol/90% ASTM Reference Fuel C <br /> 15% MTBE/85% ASTM Reference Fuel C <br /> RESULTS <br /> There was no evidence of leakage <br /> SIMULATED USE: RESISTANCE To FLUIDS TEST (FIBERGLASS REINFORCED PLASTIC SUMP <br /> MATERIALS) : <br /> METHOD <br /> one sample assembly as described in Item C was placed in a container <br /> filled with each of the fluids Listed below such that the fittings inside the <br /> container were completely covered with the fluids. The samples and fluids <br /> were maintained at a temperature of 100°F throughout the exposure. Following <br /> 30 days in this condition, the containers were subjected to an internal <br /> pressure of 4.5 psicd (based on a maximum sump depth of 10.3 ft.) for a period <br /> of at least 5 min. while the samples were examined for evidence of leakage. <br /> 1.00% Methanol <br /> 501; Methanol/501; ASTM Reference Fuel C <br /> 100% Ethanol <br /> 50% Ethanol/50% ASTM Reference Fuel. C <br /> 15% Ethanol/85% ASTM Reference Fuel C <br /> 1.0% Ethanol/90% ASTM Reference Fuel C <br /> 3.5% MTBE/85% ASTM Reference Fuel C <br /> RESULTS <br /> There was no evidence of leakage <br />
The URL can be used to link to this page
Your browser does not support the video tag.