My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_1999-2001
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
E
>
EL DORADO
>
2057
>
2300 - Underground Storage Tank Program
>
PR0231083
>
COMPLIANCE INFO_1999-2001
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/2/2020 5:05:11 PM
Creation date
6/23/2020 6:41:11 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1999-2001
RECORD_ID
PR0231083
PE
2361
FACILITY_ID
FA0003735
FACILITY_NAME
QUICK N EASY MART
STREET_NUMBER
2057
Direction
S
STREET_NAME
EL DORADO
STREET_TYPE
ST
City
STOCKTON
Zip
95206
APN
16515309
CURRENT_STATUS
01
SITE_LOCATION
2057 S EL DORADO ST
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231083_2057 S EL DORADO_1999-2001.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
315
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
� r <br /> ' UNIFIED PROGRAM CONSOLIDATED FORM <br /> TANKS <br /> UNDERGROUND STORAGE TANKS -TANK PAGE 1 <br /> (two pages per tank) <br /> ��/ Page of <br /> TYPE OF ACTION (M 1.NEW SITE PERMIT ❑ 4. AMENDED PERMIT 5. CHANGE OF INFORMATION) ❑ S. TEMPORARY SITE CLOSURE <br /> (Check one item only) „'B!J'U V L1� L � ! ❑ 7. PERMANENTLY CLOSED ON SITE <br /> ❑3.RENEWAL PERMIT (Specify reason-for local use only) (Specify change-for local use only) 1 ❑ S. TANK REMOVED 430 <br /> BUSINESS NAME(Same as FACILITY NAME or DBA-Doing Business As) FACILITY ID K 1 <br /> n <br /> y T+� <br /> LOCATION WITHIN SITE(Optionaq Fd 431 <br /> 1.TANK DESCRIPTION <br /> TANK 10 0 TANK MANUFACTURER COMPARTMENTALIZED TANK Yes ❑ No <br /> r p � <br /> If'Yes*.complete one page for each compartment. <br /> DATE INSTA ED(YEAR/MO, TANK CAPACITY IN GALLONS NUMBER OF COMPARTMENTS <br /> ADDITIONAL DESCRIPTION(Forlocal use only) <br /> 11.TANK CONTENTS <br /> TANK USE 432 PETROLEUM TYPE <br /> 21-, MOTOR VEHICLE FUEL ❑1a. ULAR UNLEADED ❑ 2. LEADED ❑ 5. JET FUEL <br /> (If marked,complete Petroleum Type) tb. PREMIUM UNLEADED ❑ 3. DIESEL ❑ 6. AVIATION FUEL <br /> ❑ 2. NON-FUEL PETROLEUM ❑1c. MIDGRADE UNLEADED ❑ 4. GASOHOL ❑99. OTHER <br /> ❑ 3. CHEMICAL PRODUCT CAS S(from Hazardous Materials Inventory page) <br /> COMMON NAME(from Hazardous Materials Inventory page) <br /> Cl 4. HAZARDOUS WASTE(Includes <br /> Used Din <br /> El 95- U8KNOWN <br /> 111.TANK CONSTRUCTION <br /> TYPE OF TANK ❑ 1. SINGLE WALL ❑ 3. SINGLE WALL WITH ❑ 5. SINGLE WALL WITH INTERNAL BLADDER SYSTEM <br /> (Check one item only) DOUBLE WALL EXTERIOR MEMBRANE LINER ❑95. UNKNOWN <br /> ❑ 4. SINGLE WALL IN A VAULT ❑99 OTHER <br /> TANK MATERIAL-primary tank ❑ 1 BARE STEEL FIBERGLASS/PLASTIC ❑ 5. CONCRETE ❑95. UNKNOWN <br /> (Check one item only) ❑ 2. STAINLESS STEEL ❑4. STEEJL CLAD W/FIBERGLASS ❑ 8. FRP COMPATIBLE W/100%METHANOL ❑99. OTHER <br /> 3EINFORCED PLASTIC(FRP) <br /> TANK MATERIAL-secondary tank ❑ 1 BARE STEEL 3. FIBERGLASS/PLASTIC ❑ 8. FRP COMPATIBLE WI100%METHANOL ❑95. UNKNOWN <br /> (Check one item only) ❑ 2. STAINLESS STEEL ❑ 4. STEEL CLAD W/FIBERGLASS ❑ 9. FRP NON-CORRODIBLE JACKET ❑99. OTHER <br /> REINFORCED PLASTIC(FRP) [110 COATED STEEL <br /> ❑ 5. CONCRETE <br /> TANK INTERIOR LINING � GATE IN TALLED <br /> OR COATING ❑ 1. RUBBER LINED ❑ 3. EPDXY LINING ❑ 5. GLASS LINING �❑,,9�5. UNKNOWN433rp���//•• ' <br /> ❑ 2.ALKYD LINING ❑ 4. PHENOLIC LINING ❑ 6 UNLINED 13d'99. OTHERf/� r'�°'-L (F local use only) <br /> (Check one item on DATE INSTALLED <br /> OTHER CO�NFSAP <br /> ION ❑ 1. MANUFACTURED CATHODIC 3. FIBERGLASS REINFORCED PLASTIC ❑95. UNKNOWN 434 <br /> PROTECTIPLICABLE PROTECTION ❑ 4. IMPRESSED CURRENT ❑99. OTHER (For localuse Only) <br /> (Check one only) ❑ 2. SACRIFICIAL ANODE <br /> SPILL AND OVERFILL R INSTALLED TYPE lFor local use only) OVERFILL PROTECTION EDUIPM <br /> -ENT:YEAR INSTALLED <br /> (Check al/that apply) 1. SPILL CONTAINMENT W ❑ 1. ALARM <br /> 3. FILL TUBE SHUT OFF VALV <br /> rer2. DROP TUBE �� ❑ 2. BALL FLOAT ❑ 4. EXEMPT <br /> 3. STRIKER PLATE <br /> N.TANK LEAK DETECTION <br /> IF SINGLE WALL TANK Check all that 8PPW1 IF DOUBLLLEE,WALL TANK OR TANK WITH BLADDER Check one item onl <br /> ❑ 1, VISUAL(EXPOSED PORTION ONLY) ❑ S. MANUAL TANK GAUGING(MTG) 4ny -41SUAL(SINGLE WALL IN VAULT ONLY) <br /> ❑ 2. AUTOMATIC TANK GAUGING(ATG) ❑ 6. VADOSE ZONE 2. CONTINUOUS INTERSTITIAL MONITORING <br /> ❑ 3. CONTINUOUSATG ❑ 7. GROUNDWATER ❑ 3. MANUAL MONITORING <br /> ❑ 4. STATISTICAL INVENTORY RECONCILIATION(SIR) ❑ 8. TANK TESTING <br /> BIENNIAL TANK TESTING ❑99. OTHER <br /> V.TANK CLOSURE INFORMATION_/PERMANENT CLOSURE IN PLACE <br /> -T <br /> ESTIMATED DATE LAST USED(YR/MO/DAY) ESTIMATED QUANTITY OF SUBSTANCE REMAINING 435 1 TANK FILLED WITH INERT MATERIAL? <br /> gallons ❑Yes ❑No <br /> v 113f0 <br /> 1 <br /> CUPAFORM(4/99) ® ® Formerly SWRCB Form B <br />