My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2012-2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
E
>
EL DORADO
>
2057
>
2300 - Underground Storage Tank Program
>
PR0231083
>
COMPLIANCE INFO_2012-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/4/2020 11:55:06 AM
Creation date
6/23/2020 6:41:17 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2012-2018
RECORD_ID
PR0231083
PE
2361
FACILITY_ID
FA0003735
FACILITY_NAME
QUICK N EASY MART
STREET_NUMBER
2057
Direction
S
STREET_NAME
EL DORADO
STREET_TYPE
ST
City
STOCKTON
Zip
95206
APN
16515309
CURRENT_STATUS
01
SITE_LOCATION
2057 S EL DORADO ST
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231083_2057 S EL DORADO_2012-2018.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
299
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
+ e <br /> The following is an itemized list of hazardous waste violations that have not been addressed <br /> for Quick Stop Mart as of June 09, 2015. <br /> Open violations from April 28, 2015 inspection <br /> Violation#325 -Spill container failed to contain a minimum capacity of five gallons. <br /> The 87 direct-bury spill container failed when tested. All spill containers shall have a minimum capacity of five <br /> gallons and be capable of containing a spill or overfill until it is detected or cleaned up. Immediately discontinue <br /> deposition of petroleum into this tank until the component is repaired or replaced by a properly licensed, trained, <br /> and certified contractor under permit and inspection of the END. If the spill container can't be replaced <br /> immediately, there is a possibility that the 87 UST system may be red tagged to prevent fuel inputs. <br /> Open violations from April 21, 2015 inspection <br /> Violation#101 -No permit to operate. <br /> A permit to operate the UST system has not been issued. No person may own or operate an UST unless a <br /> permit for its operation has been issued by the local agency to the owner or operator of the UST system. <br /> Immediately obtain a permit to operate a UST system from the EHD. An "Operating without a Permit" penalty <br /> applies. <br /> Fees for the annual permit to operate the UST system have not been paid for 2015 or 2014. No person may own <br /> or operate an UST unless a permit for its operation has been issued by the local agency to the owner or operator <br /> of the UST system. Immediately contact the EHD accounting office to make arrangements for payment to obtain <br /> a permit to operate a UST system. <br /> Violation #103 -Current financial responsibility documents not submitted. <br /> Financial responsibility documents have not been submitted to the EHD. Current financial responsibility <br /> documents are required to be submitted annually. Immediately log into the California Environmental Reporting <br /> System (CERS) at http://cers.calepa.ca.gov/, and upload the required documents. <br /> Violation #107 -Plot plan/site map not submitted or failed to completely show where monitoring is <br /> performed. <br /> An accurate UST Monitoring Site Plan was not submitted. The Monitoring Site Plan submitted on CERS does not <br /> show the locations of the annular space sensors. A site plan must be submitted identifying the locations where <br /> monitoring will be performed. Immediately log into the California Environmental Reporting System (CERS) at <br /> http://cers.calepa.ca.gov/and upload a copy of the UST Monitoring Site Plan. <br /> Violation #113 -Failed to submit monitoring system certification test report within 30 days. <br /> Annual monitoring system certification, leak detector testing, and spill container testing was performed on April 7, <br /> 2014 and a test report was submitted on June 16, 2014, one month late. A copy of the test report must be <br /> submitted within 30 days of the tests. Take all necessary precautions to ensure testing and submittal of test <br /> reports are performed in a timely manner. <br /> Page 1 of 7 <br />
The URL can be used to link to this page
Your browser does not support the video tag.