My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2012-2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
E
>
EL DORADO
>
2057
>
2300 - Underground Storage Tank Program
>
PR0231083
>
COMPLIANCE INFO_2012-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/4/2020 11:55:06 AM
Creation date
6/23/2020 6:41:17 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2012-2018
RECORD_ID
PR0231083
PE
2361
FACILITY_ID
FA0003735
FACILITY_NAME
QUICK N EASY MART
STREET_NUMBER
2057
Direction
S
STREET_NAME
EL DORADO
STREET_TYPE
ST
City
STOCKTON
Zip
95206
APN
16515309
CURRENT_STATUS
01
SITE_LOCATION
2057 S EL DORADO ST
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231083_2057 S EL DORADO_2012-2018.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
299
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
San Joaquin County <br />aEnvironmental Health Department <br />1868 Ea Hazelton Avenue, Stockton, California 952LT. 232 <br />Telephone: (209) 468-3420 Fax: (209) 468-3433 Web: www.sagov.org/ehd <br />Underground Storage Tank Program Inspection Report <br />Facility Name: <br />Facility Address: <br />Date: <br />QUICK STOP MART* <br />2057 S EL DORADO ST STOCKTON <br />Aril 21 2015 <br />SUMMARY OF VIOLATIONS <br />(CLASS I, CLASS 11, or MINOR - Notice to Comply) <br />Item # <br />Remarks <br />125 <br />CCR 2712(f) Failed to submit a written response within 30 days of receiving an inspection report. <br />An inspection was last done on April 7, 2014 and an inspection report was issued identifying information to be <br />submitted to bring this site into compliance. This information was required to be submitted by May 7, 2014. This <br />information has not been received resulting in a non-compliant status for this facility. Return to Compliance paperwork <br />for the April 1, 2013 inspection was also not submitted. The outstanding violations from 2013 include: <br />- CCR 2638 Monitoring equipment certification: (a) not performed annually; (d) test report not submitted within 30 <br />days; (e) test notification not provided to the EHD at least 48 hours prior to conducting an installation, repair, <br />replacement, calibration, or certification <br />-CCR 2715(e) Designated operator monthly inspection reports not maintained on site for at least 12 months <br />The outstanding violations from 2014 include: <br />-HSC 25284 No permit to operate <br />-HSC 25404.5 Annular operating fees not paid <br />-HSC25292.2 Current financial responsibility documents not on file with the EHD <br />-CCR 2711 Current Unified Porgram Consolidated Forms not on file with the EHD (facility and tank forms) <br />-CCR 2632(d)(1)(c) Plot plan/site map not submitted or fails to completely show where monitoring is performed <br />-CCR 2712(b) Maintenance and monitoring records not maintained 3 years. <br />-CCR 2712(i) Monitoring plan, response plan, and/or operating permit and all conditions not onsite <br />-CCR 2715(c) Designated operator monthly inspection: (1) alarms not documented; (2-4) spill containers, UDCs, and <br />sumps (if necessary) not inspected; (5) required test dates not checked or noted; (6) employee training not verified <br />-CCR 2630(d) UST monitoring equipment not installed to detect a leak at the earliest opportunity <br />-CCR 2636(f)(1) Failed to maintain a continuous monitoring system for underground piping & UDCs that activates an <br />audible and visual alarm or stops the flow of product at the dispenser when it detects a leak <br />An operator that receives an inspection report shall have 30 days to submit a written response that includes a <br />statement documenting corrective actions taken or proposing corrective actions which will be taken. Ensure that a <br />written response documenting corrective actions taken or proposed is submitted within 30 days of receiving an <br />inspection report. <br />This is a repeat violation, Class II. <br />126 <br />HSC 25404(e)(4) Failed to report program data electronically. <br />The Owner Statement of Designated UST Operator Compliance was not submitted to the the California Electronic <br />Reporting System (CERS). Beginning January 1, 2014, ail businesses are required to submit all new (or any changes <br />to existing) UST information, including: UST Monitoring Site Plan, UST Certification of Financial Responsibility, UST <br />Response Plan, UST Owner/Operator Written Agreement (if applicable), UST Letter from Chief Financial Officer, and <br />Owner Statement of Designated UST Operator Compliance online to the CERS at http://cers.calepa.ca.gov. Be sure <br />to include any other relevant activities and required fields. <br />This is a Class II violation. <br />Received b <br />Inspector:Phone: <br />Date: <br />(initial)- -&` <br />STACY RIVERA, Senior REHS <br />(209) 468-3440 <br />04/21/2015 <br />Page 5 of 10 <br />
The URL can be used to link to this page
Your browser does not support the video tag.