My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2000-2011
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
E
>
EL DORADO
>
2057
>
2300 - Underground Storage Tank Program
>
PR0231083
>
COMPLIANCE INFO_2000-2011
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/6/2024 3:49:03 PM
Creation date
6/23/2020 6:41:17 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2000-2011
RECORD_ID
PR0231083
PE
2361
FACILITY_ID
FA0003735
FACILITY_NAME
QUICK N EASY MART
STREET_NUMBER
2057
Direction
S
STREET_NAME
EL DORADO
STREET_TYPE
ST
City
STOCKTON
Zip
95206
APN
16515309
CURRENT_STATUS
01
SITE_LOCATION
2057 S EL DORADO ST
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
KBlackwell
Supplemental fields
FilePath
\MIGRATIONS\E\EL DORADO\2057\PR0231083\PERMANENT INJUNCTION & FINAL JUDGMENT 10-19-09.PDF
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
498
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN JOAQUIN COUNTY it <br /> ENVIRONMENTAL HEALTH DEPARTMENT <br /> 600 East Main Street, Stockton, California 95202-3029 <br /> Telephone:(209)468-3420 Fax:(209)468-3433 Web:www.sjgov.org/ehd/unibii.htmi <br /> CONTINUATION FORM Page: 3 of 3 <br /> OFFICIAL INSPECTION REPORT Date: 11/22/10 <br /> Facility Address: Quick Stop Mart 2057 S. EI Dorado St. Stockton, CA 95206 Program: UST <br /> SUMMARY OF VIOLATIONS <br /> CLASS I,CLASS II or MINOR-Notice to Comply) <br /> On site to witness the monitoring system certification testing and conduct the routine inspection. <br /> 4. Financial responsibility documents have not been submitted to the EHD. Current financial <br /> responsibility documents are required to be submitted annually. Complete and submit a copy of the <br /> financial responsibility by immediately. Repeat Violation. <br /> 11. The 87 and 91 stp sump sensors were raised approximately 5 inches off the lowest point of the sump <br /> part way up the saddle and not located to detect a leak at the earliest opportunity. Monitoring equipment <br /> shall be maintained to be able to detect a leak at the earliest possible opportunity. Technician corrected <br /> this during the inspection by placing the sensor at the bottom of the sump. Continue to ensure that these <br /> sensors are at the lowest point of the 87 and 91 stp sumps. Repeat Violation. <br /> 17. The 91 line leak detector failed to detect a leak when tested. All line leak detectors shall be capable <br /> of detecting a 3-gallon per hour leak at 10 psi. Immediately have a properly licensed, trained, and <br /> certified contractor repair or replace the failed leak detector (LG 113-x listed, if applicable) and obtain a <br /> permit within one business day from the EHD. If the failed leak detector can't be replaced immediately, <br /> there is a possibility that the UST system may be red tagged to prevent fuel inputs. <br /> 21. Liquid was observed in the 87 and 91 stp sumps. If water could enter into the secondary <br /> containment by precipitation or infiltration, it must be removed and disposed of properly. Technician <br /> corrected this during the inspection by removing the liquid and placing it into the HW drum on site. <br /> Continue to ensure that upon discovery, remove this liquid, make a hazardous waste determination per <br /> Title 22 hazardous waste regulations, and manage it accordingly. Ensure that the stp sumps are <br /> maintained free of liquid. Repeat Violation. <br /> Complete and submit a copy of the Return to Compliance Certification form with a statement of how <br /> each violation was corrected, including supporting documentation, by 12-22-10. <br /> ALL EHD STAFF TIME ASSOCIATED WITH FAILING TO COMPLY BY THE ABOVE NOTED DATES WILL BE BILLED AT THE CURRENT HOURLY RATE($122 . <br /> THIS FACILITY IS SUBJECT TO REINSPECTION AT NY TIME AT EHD'S CURRENT HOURLY RATE. <br /> EHD Inspector: �1�' Received B7 1 Title: <br /> EHD 23-02-003 Rev 08/10/10 CONTINUATION FORM <br />
The URL can be used to link to this page
Your browser does not support the video tag.