My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_1990-2010
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
E
>
EL DORADO
>
2320
>
2300 - Underground Storage Tank Program
>
PR0231084
>
COMPLIANCE INFO_1990-2010
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/6/2024 4:02:25 PM
Creation date
6/23/2020 6:41:26 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1990-2010
RECORD_ID
PR0231084
PE
2361
FACILITY_ID
FA0006447
FACILITY_NAME
SHELL FOOD MART
STREET_NUMBER
2320
Direction
N
STREET_NAME
EL DORADO
STREET_TYPE
ST
City
STOCKTON
Zip
95204
APN
12521030
CURRENT_STATUS
01
SITE_LOCATION
2320 N EL DORADO ST
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
KBlackwell
Supplemental fields
FilePath
\MIGRATIONS\E\EL DORADO\2320\PR0231084\EVR PHASE II PLAN 2008.PDF
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
442
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
M � D <br />HUNTER ENVIRONMENTAL SERVI� FINAL TEST RESULTS <br />15405 REDHILL AVENUE, SUITE C TEST DATE: 3-18-87 <br />TUSTIN, CALIFORNIA 92680�Ep 028 <br />1987 <br />800-247-9014 800-247-2186 <br />.%VIR0MENTAL HEpL.TH <br />RMIT /SERVICES <br />CUSTOMER: Shell LOCATION/IDENTIFICEATION NUMBER: 204-7524-3604 <br />ADDRESS: 2320 N. EI Dorado <br />Stockton, CA <br />TEST RESULTS SUMMARY <br />PRODUCT LINES - HYDROSTATIC PRESSURE TEST RESULTS <br />No. <br />S stem <br />Y <br />Tank <br />Size <br />Water <br />Level <br />Leak <br />Lokator Results* <br />No. <br />Product <br />Gallons <br />Dia/Mat) <br />Inches <br />Inches <br />ALR <br />GPH <br />Conclusion Recommendations <br />I <br />Super <br />8121 <br />95 <br />0 <br />165 <br />-.036 <br />Tight <br />2 <br />U/L <br />8121 <br />95 <br />0 <br />165 <br />-.009 <br />Tight <br />3 <br />R/L <br />10,429 <br />95 <br />0 <br />175 <br />-.010 <br />Tight <br />PRODUCT LINES - HYDROSTATIC PRESSURE TEST RESULTS <br />No. <br />System <br />Pro_ duct <br />_ T of <br />Remote <br />Puma Pounds <br />Suction A lied <br />Pounds <br />Minutes Product Product <br />Conclusion <br />Temperature <br />p <br />Com ion <br />Deltao*FsaCC/MIN <br />- .027 -9.405 <br />+ .00B +2,704 <br />+ .006 +2.605 <br />Absolute <br />Leak RaGPH <br />CCIMIN <br />-2.31 -.036 <br />- .621 -.009 <br />- .672 -.010 <br />Check <br />Y/Nte t <br />1 <br />1 <br />1 <br />—H—el —d <br />Held Loss CC's Loss GPH <br />/Result <br />1 <br />Super <br />Red Jacket <br />50 <br />49 <br />10 <br />Tight <br />2 <br />U/L <br />Red Jacket <br />50 <br />48 <br />10 <br />Tight <br />3 <br />R/L <br />Re.d Jacket <br />50 <br />49 <br />10 <br />Tight <br />Note: <br />On suction systems, <br />NEVER put more than 15 psi <br />on any pump system. <br />DETAIL OF TEST RESULTS <br />System <br />No. Product <br />1 Super <br />22 U/L <br />3 R/L <br />Test <br />No. <br />Test <br />Level <br />tIn.)Start <br />Clock <br />Time <br />Duration <br />L' -'i) <br />0-32 <br />0-33 <br />0-35 <br />Leak <br />CC/DIV <br />-10583 <br />+4.428 <br />+3.632 <br />Rate <br />CC/MIN <br />-11.714 <br />+ 2.704 <br />+ 1.933 <br />Temperature <br />p <br />Com ion <br />Deltao*FsaCC/MIN <br />- .027 -9.405 <br />+ .00B +2,704 <br />+ .006 +2.605 <br />Absolute <br />Leak RaGPH <br />CCIMIN <br />-2.31 -.036 <br />- .621 -.009 <br />- .672 -.010 <br />Check <br />Y/Nte t <br />1 <br />1 <br />1 <br />165 <br />165 <br />175 <br />2:10 <br />1:20 <br />11:20 <br />No <br />No <br />No <br />*Level - Inches from Tank Bottom to Test Level <br />ALR - Absolute Leak Rate (Measured Leak Rate - Temperature Compensation) in Gallons rEe Hour <br />Conclusion - NFPA 329 criterion of + 0.45 G,^-„ is used to certify tightness <br />CERTIFICATION <br />This is to certify that the above tank systems were tested, using the HUNTER ENVIROMENTAL <br />SERVICES, INC. LEAK LOKATOR according to all standard operating procedures. <br />Those <br />as tight at full system meet the criterion established by the National Fire Protectionlcated <br />Association Pamphlet 329 for Precision Testing. <br />Tests Conducted By: Test Van No. LL -21 <br />Tank Testi g Specialist: R. Chaverri <br />Team Man ger: Pat Wheeler <br />A <br />Cert' � Cl <br />ifie� 1y. <br />chael L. Anesetti, Field Supervisor Date <br />
The URL can be used to link to this page
Your browser does not support the video tag.