My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2001-2011
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
E
>
EL DORADO
>
2320
>
2300 - Underground Storage Tank Program
>
PR0231084
>
COMPLIANCE INFO_2001-2011
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/6/2024 4:10:21 PM
Creation date
6/23/2020 6:41:29 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2001-2011
RECORD_ID
PR0231084
PE
2361
FACILITY_ID
FA0006447
FACILITY_NAME
SHELL FOOD MART
STREET_NUMBER
2320
Direction
N
STREET_NAME
EL DORADO
STREET_TYPE
ST
City
STOCKTON
Zip
95204
APN
12521030
CURRENT_STATUS
01
SITE_LOCATION
2320 N EL DORADO ST
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
KBlackwell
Supplemental fields
FilePath
\MIGRATIONS\E\EL DORADO\2320\PR0231084\FINAL JUDGMENT 11-06-09.PDF
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
507
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
1 <br />D. Results of Testing/Servicing <br />Software Version Installed: V29.1 <br />f"mmnipto the fnllnwina chpcklict- <br />(x) Yes <br />1 ❑ No* <br />Is the audible alarm operational? <br />(x) Yes <br />❑ No* <br />Is the visual alarm operational? <br />(x) Yes <br />❑ No* <br />Were all sensors visually inspected, functionally tested, and confirmed operational? <br />(x) Yes <br />❑ No* <br />Were all sensors installed at lowest point of secondary containment and positioned so that other equipment will <br />not interfere with their proper operation? <br />( ) Yes <br />( ) No* <br />If alarms are relayed to a remote monitoring station, is all communications equipment (e.g. modem) <br />(x) N/A <br />operational? <br />(x) Yes <br />( ) No* <br />For pressurized piping systems, does the turbine automatically shut down if the piping secondary containment <br />( ) N/A <br />monitoring system detects a leak, fails to operate, or is electrically disconnected? If yes: which sensors initiate <br />positive shut -down? (Check all that apply) El Sump/Trench Sensors; ❑ Dispenser Containment Sensors. <br />Did you confirm positive shut -down due to leaks and sensor failure/disconnection? ® Yes; ❑ No. <br />( ) Yes <br />(x) No* <br />For tank systems that utilize the monitoring system as the primary tank overfill warning device (i.e. no <br />N/A <br />mechanical overfill prevention valve is installed), is the overfill warning alarm visible and audible at the tank <br />fillpoint(s) and operating ro erl ? If so, at what percent of tank capacity does tie alarm trigger? % <br />(x) Yes* <br />( ) No <br />Was any monitoring equipment replaced? If yes, identify specific sensors, probes, or other equipment replaced <br />and list the manufacturer name and model for all replacement parts in Section E, below. <br />( ) Yes* <br />( ) No <br />Was liquid found inside any secondary containment systems designed as dry systems? (Check all that apply) ❑ <br />Product; ® Water. If yes, describe causes in Section E, below. <br />(x) Yes <br />❑ No* <br />Was monitoring system set-up reviewed to ensure proper settings? Attach set up re orts, if applicable <br />(x) Yes <br />❑ No* <br />Is all monitoring equipment oerational per manufacturer's s ecifications? <br />* In Section E below, describe how and when these deficiencies were or will be corrected. <br />E. Comments: OVERFILL VALVE OPW-61 DROP TUBES INSTALLED ALL TANKS. FOUND > LESS THEN 320 <br />WATER IN DIESEL STP SUMP. NO OTHER LIQUID FOUND IN SYSTEM CONTAINMENT. REMOVED WATER <br />FROM DIESEL SUMP. <br />Monitoring System Certification Page 2 of 4 <br />2 <br />12/07 <br />
The URL can be used to link to this page
Your browser does not support the video tag.