My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2001-2011
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
E
>
EL DORADO
>
2320
>
2300 - Underground Storage Tank Program
>
PR0231084
>
COMPLIANCE INFO_2001-2011
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/6/2024 4:10:21 PM
Creation date
6/23/2020 6:41:29 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2001-2011
RECORD_ID
PR0231084
PE
2361
FACILITY_ID
FA0006447
FACILITY_NAME
SHELL FOOD MART
STREET_NUMBER
2320
Direction
N
STREET_NAME
EL DORADO
STREET_TYPE
ST
City
STOCKTON
Zip
95204
APN
12521030
CURRENT_STATUS
01
SITE_LOCATION
2320 N EL DORADO ST
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
KBlackwell
Supplemental fields
FilePath
\MIGRATIONS\E\EL DORADO\2320\PR0231084\FINAL JUDGMENT 11-06-09.PDF
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
507
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
.- ,- <br /> U <br /> NIFIED PROGRAM CONSOLIDATED FORM TANK. TA0108106 <br /> �& P <br /> Q� PR#t PR0231084 <br /> UNDERGROUND STORAGE TANKS -TANK PA 1 FAC#t FA0006447 <br /> (two pages per tank) <br /> Page 4 of 7 <br /> TYPE OF ACTION ❑ 1 NEW SITE PERMIT ❑ 4 AMENDED PERMIT ❑ 5 CHANGE OF INFORMATION ❑6 TEMPORARY SITE CLOSURE <br /> tChctk only item only) �, ,rn mY Fs `C.,a ?."�s "" " r,-M9 i�: ❑ 7 PERMANENTLY CLOSED ON SITE <br /> a <br /> ❑ 3 RENEWAL PERMIT ❑8 TANK REMOVED 430 <br /> .tea � a , z <br /> BUSINESS NAME(Same as FACILITY NAME or DBA-Doing Business Art FACILITY ID: PR#: 1 <br /> SHELL FOOD MART* 3 FA0006447 PR0231084 <br /> LOCATION WITHIN SITE(optiaui) 2320 N EL DORADO ST,STOCKTON �S"Zpt( 431 <br /> PHONE Zdq <br /> 1.TANK DESCRIPTION(A scaled plot plan with the location of the UST system including buildings and landmarks shall be submitted to the local agency.) <br /> TANK ID# Tank#: 6 432 TANK MANUFACTURER 433 COMPARTMENTALIZED TANK ❑Yes �(No 434 <br /> UTA0108106 X0 0s If"Yes".h:ompkte one page for each compartment. 1�+ <br /> DATE INSTALLED(YEAR/MO) 435 TANK CAPACITY IN GALLONS 436 NUMBER OF COMPARTMENTS 437 <br /> 19 9 D 12,000 j <br /> ADDITIONAL DESCRIPTION(For local use only) 438 <br /> II.TANK CONTENTS <br /> �,( TANK USE 439 PETROLEUM TYPE 440 <br /> W 1.MOTOR VEHICLE FUEL la.REGULAR UNLEADED ❑ 2.LEADED ❑ 5.JET FUEL <br /> (I(IfmarkedcompletePetroleumType) Qq.Ib.PREMIUM UNLEADED ❑ 3.DIESEL ❑ 6.AVIATION FUEL <br /> ❑ 2.NON-FUEL PETROLEUM T❑ Ic.MIDGRADE UNLEADED ❑4.GASOHOL ❑99.OTHER <br /> ❑ 3.CHEMICAL PRODUCT COMMON NAME(from Hazardous Materials Imentorypage) 441 CAS#(from Hazardous Materials Imemory page) 442 <br /> ❑ 4.HAZARDOUS WASTE <br /> (Ineludu Used Oil) <br /> ❑95.UNKNOWN <br /> 111.TANK CONSTRUCTION <br /> TYPE OF TANK ❑ 1.SINGLE WALL ❑3.SINGLE WALL WITH ❑ 5.SINGLE WALL WITH INTERNAL BLADDER SYSTEM 443 <br /> (F;Md.one itemonly) EXTERIOR MEMBRANE LINER ❑95.UNKNOWN <br /> 2.DOUBLE WALL ❑ 4.SINGLE WALL IN VAULT ❑99.OTHER <br /> TANK MATERIAL-primary tank ❑ 1.BARE STEEL FIBERGLASS/PLASTIC ❑ 5.CONCRETE ❑95.UNKNOWN 444 <br /> (Check one item only) ❑ 2.STAINLESS STEEL ❑STEEL CLAD W/FIBERGLASS ❑ 8.FRP COMPTIBLE W/100°/METHANOL <br /> REINFORCED PLASTIC(FRP) ❑ 99.OTHER <br /> TANK MATERIAL-secondary tank ❑ 1.BARE STEEL 3.FIBERGLASS I PLASTIC ❑ 5.CONCRETE ❑95.UNKNOWN 445 <br /> (Chmk one itern W10 ❑ 2.STAIN LESS STEEL �4.STEEL CLADW/FIBERGLASS ❑ 8.FRP COMPTIBLEW/IWI METHANOL <br /> REINFORCED PLASTIC(FRP) ❑ 10.COATED STEEL ❑ 99.OTHER <br /> ❑ 5.CONCRETE <br /> TANK INTERIOR LINING ❑ 1.RUBBER LINED ❑ 3.EPDXY LINING ❑ 5.GLASS LINING ❑95.UNKNOWN 446 DATE INSTALLED 447 <br /> OR COATING <br /> E]❑ 1�y 6 UNLINED 99-OTHER <br /> m <br /> (Check one iteonly) ❑ 2 ALKYD LINING 4 PHENOLIC LINING !� (For local use only) <br /> OTHER CORROSION ❑ I MANUFACTURING CATHODIC 1f3 FIBERGLASS REINFORCED PLASTIC ❑95 UNKNOWN 448 DATE INSTALLED 449 <br /> PROTECTION IF APPLICABLE PROTECTION <br /> ❑4IMPRESSED CURRENT ❑99 OTHER <br /> (Check one item only) ❑ 2 SACRIFICIAL ANODE (For local use only) <br /> SPILL AND OVERFILL( YEAR INSTALLE450 TYPE(local useonly) 451 OVERFILL PROTECTION EQUIPMENT:YEAR INSTALLED 452 <br /> (Chock all that applyt 1 SPILL CONTAINMENT I q 9 a V 1 ALARM 1 1 Q 1 f 'Z3 FILL TUBE SHUT OFF VAL`1?I6 0 <br /> �[ 2 DROP TUBE i 4 g o ❑ 2 BALL ❑4 EXEMPT <br /> 3 STRIKER PLATE FLOAT <br /> M.TANK LEAK DETECTION(.A descrquion of the monitoring program shall be submitted to the local agency.) <br /> IF SINGLE WALL TANK(Chale all that apply) 453 1F DOUBLE WALL TANK OR TANK WITH BLADDER 454 <br /> (Chad one item only) <br /> ❑ 1 VISUAL(EXPOSED PORTION ONLY) ❑ 5 MANUAL TANK GAUGING(MTG) ❑ I VISUAL(SINGLE WALL IN VAULT ONLY) <br /> ❑ 2 AUTOMATIC TANK GAUGING(ATG) ❑ 6 VADOSE ZONE <br /> ❑ 3 CONTINUOUS ATG ❑ 7 GROUNDWATER K2 CONTINUOUS INTERSTITIAL MONITORING <br /> ❑ 4 STATISTICAL INVENTORY RECONCILIATION ❑ 8 TANK TESTING ❑3 MANUAL MONITORING <br /> (SIR)BIENNIAL TANK TESTING ❑ "OTHER <br /> V.TANK CLOSURE INFORMATION/PERMANENT CLOSURE IN PLACE <br /> ESTIMATED DATE LAST USED(YR/MO/DAY) 455 ESTIMATED QUANTITY OF SUBSTANCE REMAINING s56 TANK FILLED WITH INERT MATERIAL'' 457 <br /> ❑Yes E] No <br /> UPCF(12/99 revised) <br />