Laserfiche WebLink
n <br />Appendix VI <br />MONITORING SYSTEM CERTIFICATION <br />For Use By All Jurisdictions Within the State of California <br />Authority Cited: Chapter 6.7, Health and Safety Code; Chapter 16, Division 3, Title 23, California Code o <br />Regulations <br />This form must be used to document testing and servicing of monitoring equipment. A separate certification or report must be prepared for <br />each monitoring system control panel by the technician who performs the work. A copy of this form must be provided to the tank system <br />owner/operator. The owner/operator must submit a copy of this form to the local agency regulating UST systems within 30 days of test date. <br />A. General information <br />Facility Bldg. No.: <br />EL DORADO FOOD SHELL <br />nano <br />Site <br />Addracc 2320 NORTH EL DORADO BLVD City: STOCKTON Zip: 95204 <br />Facility Contact <br />Parcnn Contact Phone No.: (209) 994-4400 <br />Make/Model of Monitoring System: VEEDER ROOT TLS 350 Date of Testing/Servicing: 2/11/2010 <br />B. Inventory of Equipment Tested/Certified <br />rti i, 66 � rnnrimto hnvoe to indicate snecific enuinmpnt insnerted/serviced: <br />`If the facility contains more tanks or dispensers, copy this form. Include information for every tank and dispenser at the facility. <br />C. Certification - 1 certify that the equipment identified in this document was inspected/serviced in accordance with the manufacturers' <br />guidelines. Attached to this Certification is information (e.g. manufacturers' checklists) necessary to verify that this information Is correct <br />and a Plot Plan showing the layout of monitoring equipment. For any equipment capable of generating such reports, I have also attached a <br />copy of the report; (check all that apply): S System set-up S Alarm history report <br />Technician Name (print): FELIX RAMIREZ Signature: <br />Certification No.: B34976 License No: 5273934 -UT 08-1740 OTTL <br />Testing Company Name: AFFORDA-TEST Phone No. (209) 744-0113 <br />Testing Company Address:14 6 2 STREET GALT, CA 95632 Date of Testing/Servicing: 02-11-10 <br />Monitoring System Certification Page 1 of 4 2/21/07 <br />Tank 1D: 87 <br />Tank ID: 91 <br />S In -Tank Gauging Probe, <br />Model: MAG 1 <br />S In -Tank Gauging Probe. Model: MAG 1 <br />S Annular Space or Vault Sensor. <br />Model: <br />302 <br />S Annular Space or Vault Sensor. <br />Model: 302 <br />S Piping Sump / Trench Sensor(s), <br />Model: <br />352 <br />S Piping Sump / Trench Sensor(s). <br />Model: 352 <br />❑ Fill Sump Sensor(s). <br />Model: <br />❑ Fill Sump Sensor(s). <br />Model: <br />❑ Mechanical Line Leak Detector. <br />Model: <br />❑ Mechanical Line Leak Detector. <br />Model: <br />S Electronic Line Leak Detector. <br />Model: <br />PLLD <br />S Electronic Line Leak Detector. <br />Model: PLLD <br />❑ Tank Overfill / High -Level Sensor. <br />Model: <br />❑ Tank Overfill / High -Level Sensor. <br />Model: <br />❑ Other (specify equipment type and model in Section E on Page 2). <br />❑ Other (specify equipment type and model in Section E on Page 2). <br />Tank ID: DIE <br />Tank ID: <br />❑ In -Tank Gauging Probe. <br />Model: <br />2%ln-Tank Gauging Probe. Model: MAG 1 <br />S._ Annular Space or Vault Sensor. <br />Model: <br />302 <br />❑ Annular Space or Vault Sensor. <br />Model: <br />E' Piping Sump / Trench Sensor(s). <br />Model: <br />352 <br />❑ Piping Sump / Trench Sensor(s). <br />Model: <br />❑ Fill Sump Sensor(s). <br />Model: <br />❑ Fill Sump Sensor(s). <br />Model: <br />❑ Mechanical Line Leak Detector. <br />Model: <br />❑ Mechanical Line Leak Detector. <br />Model: <br />S Electronic Line Leak Detector. <br />Model: <br />PLLD <br />❑ Electronic Line Leak Detector. <br />Model: <br />Cl Tank Overfill / High -Level Sensor. <br />Model: <br />❑ Tank Overfill / High -Level Sensor. <br />Model: <br />❑ Other (specify equipment type and model in Section E on Page 2). <br />❑ Other (specify equipment type and model in Section E on Page 2). <br />Dispenser ID: 1-2 <br />Dispenser ID: 3-4 <br />❑ Dispenser Containment Sensor(s). <br />Model: <br />❑ Dispenser Containment Sensor(s). <br />Model: <br />S ShearValve(s). <br />S Shear Valve(s). <br />S Dispenser Containment Float(s) and Chain(s). <br />S Dispenser Containment Float(s) and Chain(s). <br />Dispenser ID: 5-6 <br />Dispenser ID: 7-8 <br />❑ Dispenser Containment Sensor(s). <br />Model: <br />❑ Dispenser Containment Sensor(s). <br />Model: <br />S Shear Valve(s). <br />S Shear Valve(s). <br />S Dispenser Containment Float(s) and Chain(s). <br />S Dispenser Containment Float(s) and Chain(s). <br />Dispenser ID: <br />DispenserlD: <br />❑ Dispenser Containment <br />❑ Dispenser Containment Sensor(s). <br />Model: <br />Sensor(s). <br />Model: <br />❑ Shear Valve(s). <br />❑ Shear Valve(s). <br />❑ Dispenser Containment Float(s) and Chain(s). <br />❑ Dispenser Containment Float(s) and Chain(s). <br />`If the facility contains more tanks or dispensers, copy this form. Include information for every tank and dispenser at the facility. <br />C. Certification - 1 certify that the equipment identified in this document was inspected/serviced in accordance with the manufacturers' <br />guidelines. Attached to this Certification is information (e.g. manufacturers' checklists) necessary to verify that this information Is correct <br />and a Plot Plan showing the layout of monitoring equipment. For any equipment capable of generating such reports, I have also attached a <br />copy of the report; (check all that apply): S System set-up S Alarm history report <br />Technician Name (print): FELIX RAMIREZ Signature: <br />Certification No.: B34976 License No: 5273934 -UT 08-1740 OTTL <br />Testing Company Name: AFFORDA-TEST Phone No. (209) 744-0113 <br />Testing Company Address:14 6 2 STREET GALT, CA 95632 Date of Testing/Servicing: 02-11-10 <br />Monitoring System Certification Page 1 of 4 2/21/07 <br />