My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_1998-2008
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
E
>
EL DORADO
>
1901
>
2300 - Underground Storage Tank Program
>
PR0231092
>
COMPLIANCE INFO_1998-2008
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/6/2024 2:53:38 PM
Creation date
6/23/2020 6:41:42 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1998-2008
RECORD_ID
PR0231092
PE
2361
FACILITY_ID
FA0001946
FACILITY_NAME
El Dorado Food Mart
STREET_NUMBER
1901
Direction
S
STREET_NAME
EL DORADO
STREET_TYPE
ST
City
STOCKTON
Zip
95206
APN
16508019
CURRENT_STATUS
01
SITE_LOCATION
1901 S EL DORADO ST
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231092_1901 S EL DORADO_1998-2008.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
488
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
UNIFIED PROGRAM CONSOLIDATED FORM' <br /> TANKS <br /> UNDERGROUND STORAGE TANKS-TANK PAGE 2 <br /> Pam of <br /> � rs,atf <br /> UNDERGROUND PIPING ABOVEGROUND PIPING - <br /> SYSTEM TYPE ❑ 1. PRESSURE 2. SUCTION ❑ 3. GRAVITY ❑ 1. PRESSURE ❑ 2. SUCTION ❑ 3. GRAVITY <br /> CON4RUCTION/ 1. SINGLE WALL ❑ 3. LINED TRENCH ❑99. OTHER ❑ 1. SINGLE WALL ❑95. UNKNOWN <br /> MANUFACTURER ❑ 2. DOUBLE WALL ❑95. UNKNOWN ❑ 2. DOUBLE WALL ❑99. OTHER - <br /> MANUFACTURER MANUFACTURER <br /> ❑ 1.BARE STEEL ❑ 6. FRP COMPATIBLE W/100%METHANOL b-1. BARE STEEL ❑ 6. FRP COMPATIBLE W/100%METHANOL <br /> MATERIALS AND ❑ 2, STAINLESS STEEL ❑ 7. GALVANIZED STEEL ❑ 2. STAINLESS STEEL ❑ 7. GALVANIZED STEEL <br /> CORROSION <br /> PROTECTION ❑ 3..PLASTIC COMPATIBLE WTH CONTENTS 95. UNKNOWN ❑ 3. PLASTIC COMPATIBLE WITH CONTENTS ❑ 6. FLEXIBLE(HDPE) - ❑99. OTHER <br /> ❑ 4. FIBERGLASS ❑ S. FLEXIBLE(HDPE) 1199. OTHER ❑ 4. FIBERGLASS ❑ 9. CATHODIC PROTECTION <br /> ❑ 5. STEEL W1 COATING ❑ 9. CATHODIC PROTECTION ❑ 5. STEEL W/COATING 1195. UNKNOWN - <br /> UNDERGROUND PIPING ABOVEGROUND PIPING <br /> SINGLE WALL PIPING SINGLE WALL PIPING <br /> PRESSURIZED PIPING(Check all that apply): PRESSURIZED PIPING(Check aN that apply): - - <br /> ❑ 1. ELECTRONIC LINE LEAK DETECTOR 3.0 GPH TEST WITH AUTO PUMP SHUT OFF FOR ❑ 1. ELECTRONIC LINE LEAK DETECTOR 3.0 GPH TEST WITH AUTO PUMP SHUTOFF FOR LEAK, <br /> LEAK,SYSTEM FAILURE,AND SYSTEM DISCONNECTION+AUDIBLE AND VISUAL SYSTEM FAILURE,AND SYSTEM DISCONNECTION+AUDIBLE AND VISUAL ALARMS <br /> ALARMS ❑ 2. MONTHLY 0.2 GPH TEST <br /> ❑ 2. MONTHLY 0.2 GPH TEST ❑ 3.ANNUAL INTEGRITY TEST(0.1 GPH) <br /> ❑ 3. ANNUAL INTEGRITY TEST(0.1 GPH) ❑ 4. DAILY VISUAL CHECK <br /> CONVENTIONAL SUCTION SYSTEMS: CONVENTIONAL SUCTION SYSTEMS(Check all that apply): - <br /> ❑ 5. DAILY VISUAL MONITORING OF PUMPING SYSTEM+TRIENNIAL PIPING INTEGRITY ❑ 5. DAILY VISUAL MONITORING OF PIPING AND PUMPING SYSTEM <br /> TEST(0.1 GPH) ❑ 6. TRIENNIAL INTEGRITY TEST(0.1 GPH) <br /> SAFE SUCTION SYSTEMS(NO VALVES IN BELOW GROUND PIPING): SAFE SUCTION SYSTEMS(NO VALVES IN BELOW GROUND PIPING): <br /> ❑ 7. SELF MONITORING ❑ 7. SELF MONITORING - - - - <br /> GRAVITY FLOW: GRAVITY FLOW(Check all that apply): <br /> ❑ 9. BIENNIAL INTEGRITY TEST(0.1 GPH) ❑ S. DAILY VISUAL MONITORING <br /> ❑ 9. BIENNIAL INTEGRITY TEST(0.1 GPH) <br /> SECONDARILY CONTAINED PIPING SECONDARILY CONTAINED PIPING <br /> PRESSURIZED PIPING(Check all that apply): PRESSURIZED PIPING(Check aft that apply): - - <br /> 10. (Check NTIone US TURBINE SUMP SENSOR WITH AUDIBLE AND VISUAL ALARMS AND 10,CONTINUOUS TURBINE SUMP SENSOR WITH AUDIBLE AND VISUAL ALARMS AND(check one) <br /> ❑ a..AUTO PUMP SHUT OFF WHEN A LEAK OCCURS ❑ a. AUTO PUMP SHUT OFF WHEN A LEAK OCCURS <br /> ❑ b. AUTO PUMP SHUT OFF FOR.LEAKS,SYSTEM FAILURE AND SYSTEM ❑ b. AUTO PUMP SHUT OFF FOR LEAKS,SYSTEM FAILURE AND SYSTEM DISCONNECTION <br /> DISCONNECTION <br /> ❑ a NO AUTO PUMP SHUT OFF ❑ c. NO AUTO PUMP SHUT OFF <br /> ❑ 11. AUTOMATIC LINE LEAK DETECTOR(3.0 GPH TEST)WTH FLOW SHUT OFF OR ❑ 11.AUTOMATIC LEAK DETECTOR <br /> RESTRICTION <br /> ❑ 12. ANNUAL INTEGRITY TEST(0.1 GPH) ❑ 12.ANNUAL INTEGRITY TEST(0.1 GPH) <br /> SUCTION/GRAVITY SYSTEM: SUCTION/GRAVITY SYSTEM: - - <br /> ❑ 13. CONTINUOUS SUMP SENSOR+AUDIBLE AND VISUAL ALARMS ❑ 13. CONTINUOUS SUMP SENSOR+AUDIBLE AND VISUAL ALARMS <br /> EMERGENCY GENERATORS ONLY(Check ak that apply) EMERGENCY GENERATORS ONLY(Check all that apply) <br /> ❑ 14. CONTINUOUS SUMP SENSOR WITHOUT AUTO PUMP SHUT OFF+AUDIBLE AND ❑ 14. CONTINUOUS SUMP SENSOR WITHOUT AUTO PUMP SHUT OFF+AUDIBLE AND VISUAL <br /> VISUALALARMS ALARMS <br /> 15.AUTOMATIC LINE LEAK DETECTOR(3.0 GPH TEST)WITHOUT FLOW SHUT OFF OR ❑ 15. AUTOMATIC LINE LEAK DETECTOR(3.0 GPH TEST) <br /> RESTRICTION <br /> ❑ 16.ANNUAL INTEGRITY TEST(0.1 GPH) ❑ 16. ANNUAL INTEGRITY TEST(0.1 GPH) <br /> ❑ 17. DAILY VISUAL CHECK ❑ 17. DAILY VISUAL CHECK <br /> AM <br /> DISPENSER CONTAINMENT ❑ 1. FLOAT MECHANISM THAT SHUTS OFF SHEAR VALVE ❑ 4. DAILY VISUAL CHECK <br /> DATE INSTALLED ❑ 2. CONTINUOUS DISPENSER PAN SENSOR+AUDIBLE AND VISUAL ALARMS ❑ 5. TRENCH LINER/MONITORING <br /> ❑ 3. CONTINUOUS DISPENSER PAN SENSOR WITH AUTO SHUT OFF FOR DISPENSER+AUDIBLE AND VISUAL ALARMS ❑ 6. NONE <br /> IX.OWNER(OPERATOR SIGNATURE <br /> I certify that the information provided herein is true and accurate to the best of my knowledge. <br /> SIGNATURE OF OWNER/OPERATOR DATE <br /> NAME OF OWNERIOPERATOR(print) TITLE OF OWNER/OPERATOR <br /> I Permit Number(For local use only) Penni4 Approved(For local use onW Permit Expiration Date(Forfocal use only) <br /> i <br /> a <br /> t <br /> CUPAFORM(4/99) Formerly SWRCB Form 8 <br />
The URL can be used to link to this page
Your browser does not support the video tag.