My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2013-2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
E
>
EL DORADO
>
1901
>
2300 - Underground Storage Tank Program
>
PR0231092
>
COMPLIANCE INFO_2013-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/2/2020 4:19:40 PM
Creation date
6/23/2020 6:41:47 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2013-2018
RECORD_ID
PR0231092
PE
2361
FACILITY_ID
FA0001946
FACILITY_NAME
El Dorado Food Mart
STREET_NUMBER
1901
Direction
S
STREET_NAME
EL DORADO
STREET_TYPE
ST
City
STOCKTON
Zip
95206
APN
16508019
CURRENT_STATUS
01
SITE_LOCATION
1901 S EL DORADO ST
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231092_1901 S EL DORADO_2013-2018.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
321
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• AMENDED-� • <br /> SA N,J O A Q U I N Environmental Health Department <br /> COUNTY- <br /> --la <br /> OUNTY - Ta ��c>r ± ¢�nspe , ?n Bort <br /> Facility Name: Facility Address: Date: <br /> EL DORADO FOOD MART 1901 S EL DORADO ST, STOCKTON August 14,2018 <br /> z S[JI�tMa► © YfO TCEAli <br /> ff <br /> 1 f CLAS DG4SSt ININC3CMdticefcromph�} <br /> ,..,. �.'`m'.:� ,..= s.§?� d ._ _ • k,. ...0 tisx. ... '-s ., �' .-r,taaa .r •,:.,+ _ ;` t..x. _ <br /> Item# Remarks <br /> 106 CCR 2632(d)(2), 2634(e) Failed to have an approved UST response plan. <br /> The response plan is not current and/or not approved by the EHD.The response plan uploaded to CERS and the <br /> one found on site, list Venus McDonald as a person responsible for authorizing any work necessary under the <br /> response plan. However the owner of the site and the cashier stated that Venus no longer works for the site.The <br /> response plan must be updated and uploaded to the California Environmental Reporting System(CERS). <br /> Immediately log into CERS, upload the completed form,and submit for review by the EHD. Ensure a copy is <br /> available for inspection at any time. <br /> This is a repeat violation, Class II. <br /> 107 CCR 2632(d)(1)(C)Plot plan/site map not submitted or failed to completely show where monitoring is performed. <br /> An accurate UST Monitoring Site Plan was not submitted.The monitoring site plan is missing the general pipe <br /> layout.A site plan must be submitted identifying the locations where monitoring will be performed. Immediately log <br /> into the California Environmental Reporting System(CERS)at http://cers.calepa.ca.gov/and upload a copy of the <br /> UST Monitoring Site Plan. <br /> This is a Class II violation. <br /> 111 CCR 2638(a) Failed to test monitoring and leak detection equipment annually. <br /> The Veeder root 208 sensors in under dispenser containment(UDC) 1/2 was observed with splicing outside of the <br /> junction box.The junction box caps were missing, and spliced wiring were exposed outside of the explosion proof <br /> junction box.All monitoring equipment shall be installed, calibrated, operated and maintained in accordance with <br /> manufacturer's instructions. Immediately replace junction box caps, and properly install according to manufacturer's <br /> recommendations. Obtain a repair permit if necessary. <br /> This is a Class II violation. <br /> 113 CCR 2638(d)Failed to submit monitoring system certification test report within 30 days. <br /> Annual monitoring system certification, leak detector testing, and spill container testing was performed on 817117 <br /> and a test report was submitted on 2/20/18, 5 months late. A copy of the test report must be submitted within 30 <br /> days of the tests. Take all necessary precautions to ensure testing and submittal of test reports are performed in a <br /> timely manner. <br /> This is a Class II violation. <br /> 204 CCR 2712(i)Current monitoring plan approved by the EHD not found on site. <br /> An approved copy of the monitoring plans were not available for inspection. A copy of these plans shall be <br /> accessible on site at all times. The cashier on site, Susana Ferreira, made the correction needed while the <br /> inspector was on site. <br /> This was corrected on site. <br /> This is a Class II violation. <br /> FA0001946 PR0231092 SCO01 08/14/2018 <br /> EHD 23-01 Rev.10/31/2017 Page 4 of 5 Underground Storage Tank Program OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />
The URL can be used to link to this page
Your browser does not support the video tag.