Laserfiche WebLink
0 0 ec v" <br />Page 2 of 9:, <br />Test Method Developed By: <br />❑ Tank Manufacturer ® Industry Standard ❑ Professional Engineer <br />10 min <br />❑ Other (Specify) <br />Test Method Used: <br />❑ Pressure <br />® Vacuum ❑ Hydrostatic <br />❑ Other (Speco) <br />Initial Reading(Rj): <br />Test Equipment Used: Vacuum Gauge <br />7 Hg <br />Equipment Resolution: 0-30 Hg <br />Test End Time: <br />2:10 PM <br />2:10 PM <br />Tank # 87 <br />Tank # 91 <br />Tank # <br />Tank # <br />Is Tank Exempt From Testing?' <br />❑ Yes ® No <br />❑ Yes ® No <br />60 min <br />Tank Capacity: <br />9000 Gal <br />3000 Gal <br />0 <br />Tank Material: <br />D/W Steel <br />D/W Steel <br />7 Hg <br />Tank Manufacturer: <br />Unknown <br />Unknown <br />Product Stored: <br />Unleaded 87 <br />Unleaded 91 <br />Wait time between applying <br />pressure/vacuum/water and <br />starting test: <br />10 min <br />10 min <br />Test Start Time: <br />1:10 PM <br />1:10 PM <br />Initial Reading(Rj): <br />7 Hg <br />7 Hg <br />Test End Time: <br />2:10 PM <br />2:10 PM <br />Final Reading (RF): <br />7 Hg <br />7 Hg <br />Test Duration: <br />60 min <br />60 min <br />Change in Reading (RF -R,): <br />0 <br />0 <br />Pass/Fail Threshold or Criteria: <br />7 Hg <br />7 Hg <br />I est 1(CJniL: \j rasa Ly r..all ';." 145b {— 1, all ;U I aaa ".i•ai. U a — L i a,.a.. <br />Was sensor removed for testing? ®Yes [—]No [INA ®Yes ❑No [:INA ❑Yes ❑No [:INA ❑Yes [:]No [:INA <br />Was sensor properly replaced and ❑Yes [—]No [:]NA ®Yes [—]No[:INA[:]Yes❑No ❑NA [:]Yes ❑No ❑NA <br />verified functional after testing? <br />Comments — (include information on repairs made prior to testing, and recommended follow-up,foi- failed tests) <br />Tanks 87 and 91 are two partitions of one tank - only one Annular Space <br />2015 <br />ta17 ^ L "'v nr-1,. n—a -- <br />' Secondary containment systems where the continuous monitoring automatically monitors both the primary and secondary <br />containment, such as systems that are hydrostatically monitored or under constant vacuum, are exempt from periodic containment <br />testing. {California Code of Regulations. Title 23. Section 26 37(a)(6)} <br />