My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_1987-1992
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
E
>
EL DORADO
>
7906
>
2300 - Underground Storage Tank Program
>
PR0231094
>
COMPLIANCE INFO_1987-1992
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/10/2023 12:03:21 PM
Creation date
6/23/2020 6:42:01 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1987-1992
RECORD_ID
PR0231094
PE
2361
FACILITY_ID
FA0003632
FACILITY_NAME
AJS MINI MART INC
STREET_NUMBER
7906
Direction
N
STREET_NAME
EL DORADO
STREET_TYPE
ST
City
STOCKTON
Zip
95207
APN
07935016
CURRENT_STATUS
01
SITE_LOCATION
7906 N EL DORADO ST
P_LOCATION
01
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231094_7906 N EL DORADO_1987-1992.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
495
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
STATE OF CALIFORNO WATER RESOURCES CONT*'BOARD <br /> FORM V: UNDERGROUND STORAGE TANK PROGRAM A <br /> TANK PERMIT APPLICATION INFORMATION "�.. ., <br /> TANK'� COMPLETE A SEPARATE FORM WITH THE FOLLOWING INFORMATION FOR EACH TANK. °4lli <br /> MARK ONLY 1 NEW PERMIT ❑ 3 RENEWAL PERMIT ❑ 5 CHANGE OF INFORMATION ❑7 PERMANENTLY CLOSED TANK <br /> ONE ITEM ❑ 2 INTERIM PERMIT ❑4 AMENDED PERMIT ❑6 TEMPORARY TANK CLOSURE ❑8 TANK REMOVED /f <br /> FACILITY/SITE NAME WHERE TANK IS INSTALLED: (� r- C FARM TANK-YES❑ NO �' <br /> i <br /> I� L TANK DESCRIPTION COMPLETE ALL ITEMS-IF UNKNOWN-SO SPECIFY I d <br /> A. OWNERS TANK ID# JV A- B. MANUFACTURED BY: UK <br /> C. YEAR INSTALLED - D. TANK CAPACITY IN GALLONS: 4000 <br /> W <br /> II. TANK_CONTENTS IF(A.1),IS MARKED,COMPLETE ITEM C.IF(A.1),IS NOT MARKED,COMPLETE ITEM D. C?I <br /> A. 1 MOTOR VEHICLE FUEL ❑ 2 PETROLEUM B. C• ❑ 1 UNLEADED 2 LEADED ❑ 3 DIESEL <br /> F-]3 CHEMICAL PRODUCT F-] 4 OIL RODUCT ❑ 4 GASAHOL ❑ 5 JET FUEL ❑ 6 AVIATION GAS <br /> ❑ 5 HAZARDOUS ❑ 80 EMPTY ❑ 95 UNKNOWN ❑ 2 WASTE ❑ 7 METHANOL ❑ 99 OTHER(DESCRIBE IN ITEM D,BELOW) <br /> D. IF NOT MOTOR VEHICLE FUEL,ENTER NAME OF <br /> HAZARDOUS SUBSTANCE STORED&C.A.S.# C.A.S.#: <br /> x111. TANK CONSTRUCTION MARK ONE ITEM ONLY IN BOX A,B,C,&D <br /> i <br /> r C A.TYPE OF F-] 1 DOUBLE WALLED F-13 SINGLE WALLED WITH EXTERIOR LINER 95 UNKNOWN SYSTEM 2 SINGLE WALLED ❑4 SECONDARY CONTAINMENT ❑99 OTHER <br /> 1 STEEL/IRON ❑2 STAINLESS STEEL ❑3 FIBERGLASS ❑4 STEEL CLAD W/FIBERGLASS REINFORCED PLASTIC <br /> B.TANK ❑5 CONCRETE ❑6 POLYVINYL CHLORIDE ❑7 ALUMINUM ❑8 100%METHANOL COMPATIBLE FRP <br /> MATERIAL ❑9 BRONZE 10 GALVANIZED STEEL ❑95 UNKNOWN 99 OTHER <br /> F-11 RUBBER LINED ❑2 ALKYD LINING ❑3 EPDXY LINING E]4 PHENOLIC LINING <br /> C.INTERIOR <br /> LINING F-16 U <br /> 5 GLASS LINING NLINED 95 UNKNOWN <br /> ❑ IS LINING MATERIAL COMPATIBLE WITH 100%METHANOL? ❑YES ❑ NO ❑99 OTHER <br /> 0.CORROSION ❑ 1 POLYETHLENE WRAP ❑2 TAR OR ASPHALT F-1 3 VINYL WRAP E]4 FIBERGLASS REINFORCED PLASTIC <br /> PROTECTION ❑5 CATHODIC PROTECTION91 NONE ❑95 UNKNOWN ❑99 OTHER <br /> IV. PIPING INFORMATION CIRCLE A IF ABOVE GROUND, U IF UNDERGROUND,BOTH IF APPLICABLE <br /> L. A.SYSTEM TYPE A U 1 SUCTION AU 2 PRESSURE A U 3 GRAVITY A U 99 OTHER <br /> f B.CONSTRUCTION A 01 SINGLE WALLED A U 2 DOUBLE WALLED A U 3 LINED TRENCH A U 95 UNKNOWN A U 99 OTHER <br /> I A U 1 STEEL/IRON A U 2 STAINLESS STEEL A U 3 POLYVINYL CHLORIDE(PVC) A U 4 FIBERGLASS PIPE <br /> C. MATERIAL A U 5 ALUMINUM A U 6 CONCRETE A U 7 STEEL CLAD W/FRP A U 8 100%METHANOL COMPATIBLE FRP <br /> A U 9 GALVANIZED STEEL A U 95 UNKNOWN A U 99 OTHER <br /> V. LEAK DETECTION SYSTEM CIRCLE P FOR PRIMARY,OR S FOR SECONDARY,A PRIMARY LEAK DETECTION SYSTEM MUST BE CIRCLED. <br /> / P S 1 VISUAL CHECK P S 2 INVENTORY RECONCILIATION P S 3 VADOSE WELLS P S 4 ELECTRONIC MONITOR P S 5 GROUND WATER MONITORING WELLS <br /> P S 6 PRECISION TESTING P S 7 PRESSURE TESTING P S 91 NONE P S 95 UNKNOWN S 99 OTHER <br /> VI. INFORMATION ON TANK PERMANENTLY CLOSED IN PLACE <br /> 1. ESTIMATED DATE LAST USED(MO/YR) 2. ESTIMATED QUANTITY OF 3.WAS TANK FILLED WITH <br /> SUBSTANCE REMAINING IN GALLONS INERT MATERIAL? YES [:] NO <br /> fTHIS FORM HAS BEEN COMPLETED UNDER PENALTY OF PERJURY,AND TO THE BEST OF MY KNOWLEDGE,IS TRUE AND CORRECT. <br /> I APPLICANT'S NAME(PRINTED&SIGNATURE) DATE <br /> I <br /> I4 LOCAL AGENCY USE ONLY <br /> E <br /> COUNTY# JURISDICTION# AGENCY# FACILITY ID# TANK ID# <br /> F5FO 10 L3 I <br /> f CURRENT LOCAL AGENCY FACILITY ID# AP VED BY NAMf PHONE#WITH AREA CODE <br /> PERMIT NUMBER PERMIT APPROVAL DA E PERMI EXPIRATION DATE <br /> PERMIT NUMBER T <br /> I <br /> CHECK# PERMIT AMOUNTSURCHARGE AMT. FEE CODE RECEIPT# BY: <br /> Y FORM B(3-7-88) THIS FORM MUST BE ACCOMPANI Y A FACILITY/SITE APPLICATION, FORM`A',UNLESS A RENT FORMA' HAS BEEN FILED <br /> f DATA PROCESSING COPY <br />
The URL can be used to link to this page
Your browser does not support the video tag.