My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2002-2005
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
E
>
EL DORADO
>
7906
>
2300 - Underground Storage Tank Program
>
PR0231094
>
COMPLIANCE INFO_2002-2005
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/23/2020 2:10:05 PM
Creation date
6/23/2020 6:42:08 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2002-2005
RECORD_ID
PR0231094
PE
2361
FACILITY_ID
FA0003632
FACILITY_NAME
AJS MINI MART INC
STREET_NUMBER
7906
Direction
N
STREET_NAME
EL DORADO
STREET_TYPE
ST
City
STOCKTON
Zip
95207
APN
07935016
CURRENT_STATUS
01
SITE_LOCATION
7906 N EL DORADO ST
P_LOCATION
01
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231094_7906 N EL DORADO_2002-2005.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
298
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
T <br /> UNIFIED PROGRAM CONSOLIDATED FORM <br /> TANKS 12, l'l� <br /> UNDERGROUND STORAGE TANKS - TANK PAGE l <br /> ('Iwo pages per tank) <br /> Page I of 2 <br /> TYPE OF ACTION ❑ I.NEW PERMIT ❑ 4.AMENDED PERMIT ® 5.CHANGE Oh INFORMATION ❑ 6.TEMPORARY TANK CLOSURE; 430 <br /> (Check one item only) ❑ 3.RENEWAL PERMIT _system modiffication ❑ 7.PERMANENTLY CLOSED ON SITE <br /> (Specify reason) (Specify reason) ❑ 8.TANK REMOVED <br /> BUSINESS NAME(Same as FACILITY NAME or DBA-Doing Business As) 3. 1 FACILITY ID: I I <br /> ARCO 2130 3 !v �- <br /> LOCATION WITHIN SITE(Optional) 431 <br /> 6142 Al. L Demclo <br /> I.TANK DESCRIPTION <br /> (A scaled plot plan with the location of the UST system including buildings and landmarks shall be submitted to the local agency.) <br /> TANK ID#bybyps/ 432 TANK MANUFACTURER 433 COMPARTMENTALIZED TANK ❑ Yes ® No 434 <br /> #/ -UNLEADED XERXES 1f"Yes,"complete one page for each compartment. <br /> DATE INSTALLED 435, TANK CAPACITY IN GALLONS 436 NUMBER OF COMPARTMENTS 437 <br /> (YEAR/MO) <br /> 1993/6 10,000 <br /> ADDITIONAL DESCRIPTION(For local use only) 438 <br /> I1.TANK CONTENTS <br /> TANK USE 439. PETROLEUM TYPE 440 <br /> ® 1. MOTOR VEHICLE FUEL ®la. REGULAR UNLEADED ❑2. LEADED ❑5. JET FUEL <br /> (Ifchecked,complete petroleum Type) ❑Ib. PREMIUM UNLEADED [13. DIESEL ❑6. AVIATION GAS <br /> ❑ 2. NON-FUEL PETROLEUM ❑ Ic. MIDGRADE-UNLEADED ❑4. GASOHOL ❑99.OTHER: <br /> ❑ 3. CHEMICAL PRODUCT COMMON NAME (from Hazardous Materials Inventory page) 441 CAS#(from Hazardous Materials Inventory page) 442 <br /> ❑ 4. HAZARDOUS WASTE Gasoline 8006-61-9 <br /> (Includes Used Oil) <br /> ❑ 95.UNKNOWN <br /> II1.TANK CONSTRUCTION <br /> TYPE OF TANK ❑ 1. SINGLE WALL ❑3. SINGLE WALL WITH EXTERIOR [15. SINGLE WALL WITH INTERNAL BLADDER SYSTEM 443 <br /> (Check one item only) MEMBRANE LINER [195. UNKNOWN <br /> ®2. DOUBLE WALL [14. SINGLE WALL IN A VAULT [199. OTHER <br /> TANK MATERIAL-primary tank ❑ 1. BARE STEEL 93. FIBERGLASS/PLASTIC ❑5. CONCRETE ❑95.UNKNOWN 444 <br /> (Check one item only) ❑2. ST AINLESS STEEL [14. STEEL CLAD W/FIBERGLASS ❑8. FRP COMPATIBLE ❑99.OTHER: <br /> REINFORCED PLASTIC(FRP) W/100%METHANOL <br /> TANK MATERIAL-secondary tank ❑1. BARE STEEL ®3. FIBERGLASS/PLASTIC ❑8. FRP COMPTIBLE W/100%METHANOL ❑95.UNKNOWN 445. <br /> (Check one item only) ❑2. STAINLESS STEEL❑4. STEEL CLAD W/FIBERGLASS ❑9. FRP NON-CORRODABLE JACKET ❑99.OTHER <br /> REINFORCED PLASTIC(FRP) ❑ 10. COATED STEEL <br /> ❑5. CONCRETE <br /> TANK INTERIOR LINING ❑1.RUBBER LINED ❑3.EPDXY LINING ❑5.GLASS LINING ❑95.UNKNOWN 446 DATE INSTALLED 447. <br /> OR COATING ❑2.ALKYD LINING ❑4.PHENOLIC LINING ®6.UNLINED ❑99.OTHER <br /> (Check one item only) <br /> OTHER CORROSION ❑ 1.MANUFACTURED CATHODIC ❑3.FIBERGLASS REINFORCED PLASTIC ❑95.UNKNOWN 448. DATE INSTALLED 449. <br /> PROTECTION PROTECTION ❑4.IMPRESSED CURRENT ❑99.OTHER <br /> (If A licable) 2.SACRIFICIAL ANODE <br /> SPILL AND OVERFILL YEAR INSTALLED 450. TYPE 451 1 OVERFILL PROTECTION EQUIPMENT: YEAR INSTALLED 452 <br /> (Check all that apply) ®1.SPILL CONTAINMENT 1993 ❑ 1.ALARM 10 3.FILL TUBE SHUT OFF VALVE <br /> ®2.DROP TUBE- 1993 ❑2.BALL FLOAT ❑4.EXEMPT <br /> ❑3.STRIKER PLATE <br /> IV.TANK LEAK DETECTION <br /> (A description of the monitoring program shall be submitted to the local agency.) <br /> IF SINGLE WALL TANK 453. IF DOUBLE WALL TANK OR TANK WITH BLADDER 454 <br /> (Check all that apply) (Check one item only) <br /> ❑1. VISUAL(EXPOSED PORTION ONLY) ❑5.MANUAL TANK GAUGING(MTG) ❑ 1.VISUAL(SINGLE WALL IN VAULT ONLY) <br /> ❑2. AUTOMATIC TANK GAUGING(ATG) ❑6.VADOSE ZONE- ®2.CONTINUOUS INTERSTITIAL MONITORING <br /> ❑3.CONTINUOUS ATG [17.GROUNDWATER ❑3.MANUAL MONITORING <br /> ❑4. STATISTICAL INVENTORY RECONCILIATION ❑S.TANK TESTING <br /> (SIR)+BIENNIAL TANK TESTING ❑99.OTHER <br /> V.TANK CLOSURE INFORMATION/ PERMANENT CLOSURE IN PLACE <br /> ESTIMATED DATE LAST USED(YR/MO/DAY) 455. ESTIMATED QUANTITY OF SUBSTANCE REMAINING 456 TANK FILLED WITH INERT MATERIAL? 457 <br /> gallons ❑Yes ❑ No <br /> UPCF Mvftvrc-b(1199)-1/4 http://w«-w.uniclocs.org Rev.02/16/00 <br />
The URL can be used to link to this page
Your browser does not support the video tag.