Laserfiche WebLink
FIED PROGRAM CONSOLIDATED FORM 1 y TANK: TA0508147 <br /> PR#: PR0231111 <br /> UNDERGROUND STORAGE TANKS -TANK PAGE 1 ` FAC#: FA0001659 <br /> (two pages per tank) <br /> Page 2 of 5 <br /> TYPE OF ACTION ❑ 1 NEW SITE PERMIT ❑ 4 AMENDED PERMIT ❑ 5 CHANGE OF INFORMATION ❑ 6 TEMPORARY SITE CLOSURE <br /> (Check only item only) E I a l s, <br /> � b `) �'`)l ' ❑ 7 PERMANENTLY CLOSED ON SITE <br /> ❑ 3 RENEWAL PERMIT ❑8 TANK REMOVED 430 <br /> BUSINESS NAME(Same as FACILITY NAME or DBA-Doing Business As) 3 FACILITY ID: PR#: 1 <br /> QUIK STOP MARKETS#39 FA0001659 PR0231111 <br /> LOCATION WITHIN SITE(Optional) 2285 E FREMONT ST,STOCKTON 431 <br /> PHONE <br /> I.TANK DESCRIPTION(A scaled plot plan with the location of the UST system including buildings and landmarks shall be submitted to the local agency.) <br /> TANK ID# Tank#: 3 432 TANK MANUFACTURER C 433 COMPARTMENTALIZED TANK E]Yes 21No 434 <br /> TA0508147 XERXES If"Yes",complete one page for each compartment. <br /> DATE INSTALLED(YEAR/MO) 435 TANK CAPACITY IN GALLONS 436 NUMBER OF COMPARTMENTS 437 <br /> 10/1/1998 12,000 1 <br /> ADDITIONAL DESCRIPTION(For local use only) 438 <br /> II.TANK CONTENTS <br /> TANK USE 439 PETROLEUM TYPE 440 <br /> ® 1.MOTOR VEHICLE FUEL ® la.REGULAR UNLEADED ❑ 2.LEADED ❑ 5.JET FUEL <br /> (If marked complete Petroleum Type) <br /> ❑ lb.PREMIUM UNLEADED ❑ 3.DIESEL ❑ 6.AVIATION FUEL <br /> ❑ 2.NON-FUEL PETROLEUM ❑ lc.MIDGRADE UNLEADED ❑ 4.GASOHOL ❑99.OTHER <br /> ❑ 3.CHEMICAL PRODUCT COMMON N from Hazardous Materials Inventory a from i <br /> Hazardous Materials inventory a <br /> AMS( N e P 8) 441 CAS#( ry e p g) 442 <br /> ❑ 4.HAZARDOUS WASTED A� // rs u/t /�� e IC-A <br /> (Includes Used Oil) -7•q0[ C'� (}!'1. L C p.,H,(, OU /' (' <br /> ❑ 95.UNKNOWN ti L r- f�►1 Z� (�U c <br /> o E J III.TANK CONSTRUCTION <br /> TYPE OF TANK ❑ 1.SINGLE WALL ❑ 3.SINGLE WALL WITH ❑ 5.SINGLE WALL WITH INTERNAL BLADDER SYSTEM 443 <br /> (Check one item only) EXTERIOR MEMBRANE LINER ❑95.UNKNOWN <br /> ® 2.DOUBLE WALL ❑ 4.SINGLE WALL IN VAULT ❑ 99.OTHER <br /> TANK MATERIAL-primary tank ❑ 1.BARE STEEL FIBERGLASS/PLASTIC ❑ 5.CONCRETE ❑ 95.UNKNOWN 444 <br /> (Check one item only) ❑ 2.STAINLESS STEEL ❑ STEEL CLAD W/FIBERGLASS e8.FRP COMPTIBLE W/100%METHANOL <br /> REINFORCED PLASTIC(FRP) ❑ 99.OTHER <br /> TANK MATERIAL-secondary tank ❑ 1.BARE STEEL ❑ 3.FIBERGLASS/PLASTIC ❑ 5.CONCRETE ❑ 95.UNKNOWN 445 <br /> (Check one item only) ❑ 2.STAINLESS STEEL ❑4.STEEL CLAD W/FIBERGLASS 2118.FRP COMPTIBLE W/100%METHANOL <br /> REINFORCED PLASTIC(FRP) ❑ 10.COATED STEEL ❑ 99.OTHER <br /> ❑ 5.CONCRETE <br /> TANK INTERIOR LINING ❑ 1.RUBBER LINED ❑ 3.EPDXY LINING ❑ 5.GLASS LINING ❑95.UNKNOWN 446 DATE INSTALLED 447 <br /> OR COATING <br /> (Check one item only) ❑ 2 ALKYD LINING ❑ 4 PHENOLIC LINING ® 6 UNLINED ❑ 99.OTHER <br /> (For local use only) <br /> OTHER CORROSION ❑ 1 MANUFACTURING CATHODIC ® 3 FIBERGLASS REINFORCED PLASTIC ❑ 95 UNKNOWN 448 DATE INSTALLED 449 <br /> PROTECTION IF APPLICABLE PROTECTION <br /> (Check one item only) ❑ 4 IMPRESSED CURRENT ❑ 99 OTHER <br /> ❑2 SACRIFICIAL ANODE (For local use only) <br /> SPILL AND OVERFILL YEAR INSTA-LE450 TYPE(local use only) 451 OVERFILL PROTECTION EQUIPMENT:YEAR INSTALLED 452 <br /> (Check all that apply) rLl/1 SPILL CONTAINMENT }y5911S-9H191 ❑ 1 ALARM Rr003 FILL TUBE SHUT OFF VAL` /949 <br /> Ee2 DROP TUBE C19 g ❑ 2 BALL ❑4 EXEMPT <br /> 2"3 STRIKER PLATE /i/ FLOAT <br /> IV.TANK LEAK DETECTION(A description of the monitoring program shall be submitted to the local agency.) <br /> IF SINGLE WALL TANK(Cheek all that apply) 453 IF DOUBLE WALL TANK OR TANK WITH BLADDER 454 <br /> ❑ 1 VISUAL(EXPOSED PORTION ONLY) ❑ 5 MANUAL TANK GAUGING(MTG) (Check one item only) <br /> ❑ 2 AUTOMATIC TANK GAUGING(ATG) ❑ 6 VADOSE ZONE <br /> ❑ 1 VISUAL(SINGLE WALL IN VAULT ONLY) <br /> ❑ 3 CONTINUOUS ATG ❑ 7 GROUNDWATER ®2 CONTINUOUS INTERSTITIAL MONITORING <br /> ❑ 4 STATISTICAL INVENTORY RECONCILIATION ❑ 8 TANK TESTING ❑3 MANUAL MONITORING <br /> (SIR)BIENNIAL TANK TESTING ❑ 99 OTHER <br /> V.TANK CLOSURE INFORMATION/PERMANENT CLOSURE IN PLACE <br /> ESTIMATED DATE LAST USED(YR/MO/DAY) a55 ESTIMATED QUANTITY OF SUBSTANCE REMAINING 456 TANK FILLED WITH INERT MATERIAL? 457 <br /> ❑Yes ❑No <br /> UPCF(12/99 revised) <br />