Laserfiche WebLink
• <br />SAN JOAQUIN COUNTY <br />ENVIRONMENTAL HEALTH DEPARTMENT <br />Is <br />600 East Main Street, Stockton, California 95202-3029 <br />Telephone: (209) 468-3420 Fax: (209) 468-3433 Web: www.sagov.org/ehd/unitiii.htmi <br />UNDERGROUND STORAGE TANK (UST) PROGRAM INSPECTION REPORT <br />Facility name: <br />Inspection date: <br />Quick Stop Markets #39 <br />August 15, 2011 <br />Facility address: <br />UST # / <br />3 <br />4 <br />2285 E. Fremont, Stockton <br />Product <br />/ 87 <br />91 <br />Facility contact: Title: Phone: <br />Mike Karvelot Director Env. Affairs 510-445-2285 <br />Monitoring panel: <br />Piping system: <br />prevention: <br />Violations: <br />Gilbarco EMC <br />❑X Pressurized ❑Suction❑Gravity <br />�dverfill <br />Mechanical <br />❑Audiblemisual <br />❑X M1-RDetect ❑M2-RPrev ❑ M3 -Both <br />Inspection type: <br />Designated operator: ICC exp. date: <br />❑X Routine ❑X Monitoring Certification E] Installation []Other <br />Jeff Covan (Walton) 8079216 9/1/2012 <br />On site Service Technician's name: ICC exp. date: <br />Manufacturer's training: <br />Curtis Carpenter (8020679) 7/28/12 <br />VMI #2816 (12/6/12); VR B37U258 (1/27/13) <br /># <br />Code Section <br />VIOLATIONS <br />V <br />R <br />HSC=CA Health & Safety Code; CCR=CA Code of Regulations; V=Violation; RV=Re eat Violation <br />V <br />1 <br />HSC 25284 <br />No permit tooperate <br />Secondary containment: (a) test not performed; (e) test report not submitted within 30 days; (f) test <br />2 <br />CCR 2637 <br />notification not provided to the Environmental Health Department (EHD) at least 48 hours prior to <br />conducting the test %a.t-f // 1 /t o I () <br />3 <br />CCR 2711 b <br />Current Unified Program Consolidated Forms not on file with the EHD(Facility and tank form <br />4 <br />HSC 25292.2 <br />Current financial responsibility documents not on file with the EHD <br />5 <br />CCR 2632(b) <br />Monitoring Program(Monitoring & Response Plans is not current or approved by the EHD <br />X <br />6 <br />CCR 2712(i) <br />Monitoring Ian, response plan, and/oroperating permit and all conditions not onsite <br />Maintenance & monitoring records not maintained 3 years, cathodic protection records for 6'/2 (Mt) <br />years, written performance claims pertaining to release detection systems for 5 years, or records of <br />repairs, linings, and upgrades for the life of the tank. Monitoring records include: (1) date and time of <br />X <br />7 <br />CCR 2712(b) <br />all monitoring or sampling; (2) monitoring equipment calibration and maintenance records; (3) results <br />of any visual observations; (4) results of sample analysis performed a lab or in the field; (5) logs of all <br />readings of gauges or other monitoring equipment, ground water elevations, or other test results; (6) <br />results of inventory readings and reconciliations <br />8 <br />CCR 2643(d) <br />Daily monitoring of suction piping (pre-January1, 1984 not performed M1) <br />9 <br />HSC 25292.1 <br />UST system is not operated to prevent unauthorized release, including spills and overfills <br />10 <br />CCR 2632(c)(2) <br />Monitoring system is not present in the interstitials ace of a double walled UST M1) <br />11 <br />CCR 2630(d) <br />UST monitoring equipment is not installed or maintained to detect a leak at the earliest opportunity(mi) <br />UST monitoring system incapable of detecting leak from primary containment into secondary (M1) <br />12 <br />HSC 25291(b) <br />containment <br />Failed to maintain a continuous monitoring system for underground piping & UDCs that activates (Mt) <br />13 <br />CCR 2636(f)(1) <br />an audible and visual alarm or stops flow of product at the dispenser when it detects a leak <br />14 <br />CCR 2631 a <br />Primary containment is not product tight <br />15 <br />HSC 25291 (a)(2) <br />Secondary containment for UST system is not tight <br />16 <br />CCR 2636 c 1 <br />All releases in secondary pipingdo not flow to a collection sum <br />17 <br />CCR 2636 2 <br />Line leak detectors not installed or failed to detect a 3 -gallon per hour leak at 10 psi (Mt) <br />Spill container failed to contain a minimum capacity of five gallons, or failed to provide a means (M2) <br />18 <br />CCR 2635(b)(1) <br />to keep the spill container empty <br />19 <br />CCR 2635(b)(2) <br />Overfill' prevention system was overridden or failed to meet overfill requirements in this section (M2) <br />20 <br />CCR 2636(a) <br />Failed to have secondary containment for piping (includes conventional suction piping) (M2) <br />21 <br />HSC 25291(e) <br />Water in 21 containment not removed, analyzed & properly disposed of <br />X <br />Unauthorized release that: (c) did not escape secondary containment and cleaned up within eight (Mt) <br />22 <br />CCR 2650 <br />hours was not recorded; (e) escaped secondary containment, not cleaned up after eight hours, or a <br />sudden loss of product was not reported to the EHD within 24 hours <br />23a <br />CCR 2715(a) <br />Failed to inform the EHD of a change of designated operator within 30 days <br />Tk <br />23b <br />CCR 2715(b) <br />Designated operator did not possess a current ICC UST System Operator certification <br />X <br />EHD inspector: <br />Received by: <br />Title: <br />EHD 23-02002 RE�0d13( / Page 1 UST INSPECTION REPORT <br />