My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2006-2013
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
F
>
FREMONT
>
2285
>
2300 - Underground Storage Tank Program
>
PR0231111
>
COMPLIANCE INFO_2006-2013
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/26/2021 9:09:52 AM
Creation date
6/23/2020 6:43:01 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2006-2013
RECORD_ID
PR0231111
PE
2361
FACILITY_ID
FA0001659
FACILITY_NAME
QUIK STOP MARKET #7039
STREET_NUMBER
2285
Direction
E
STREET_NAME
FREMONT
STREET_TYPE
ST
City
STOCKTON
Zip
95205
APN
141-214-03
CURRENT_STATUS
01
SITE_LOCATION
2285 E FREMONT ST
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231111_2285 E FREMONT_2006-2013.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
466
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
FIED PROGRAM CONSOLIDATED FCFW <br />UNDERGROUND STORAGE TANK <br />OPERATING PERMIT APPLICATION - TANK INFORMATION (One form per UST) <br />TYPE OF ACTION (Check one item only. For an UST permanent closure or removal, complete only this section and Sections I, II, III, IV, and IX below) 430 <br />X 1. NEW PERMIT ❑ 3. RENEWAL PERMIT ❑ 5. CHANGE OF INFORMATION <br />❑ 6. TEMPORARY UST CLOSURE ❑ 7. UST PERMANENT CLOSURE ON SITE ❑ 8. UST REMOVAL <br />DATE UST PERMANENTLY CLOSED: 431a DATE EXISTING UST DISCOVERED: 430b <br />TANK USE x la. MOTOR VEHICLE FUELING ❑ lb. MARINA FUELING ❑ 1c. AVIATION FUELING 439 <br />❑ 3. CHEMICAL PRODUCT STORAGE ❑ 4. HAZARDOUS WASTE (Includes Used Oil) ❑ 5. EMERGENCY GENERATOR FUEL [HSC §25281.5(c)] <br />❑ 6. OTHER GENERATOR FUEL ❑ 95. UNKNOWN ❑ 99. OTHER (Specify): 439a <br />CONTENTS PETROLEUM: X la. REGULAR UNLEADED ❑ lc. MIDGRADE UNLEADED ❑ lb. PREMIUM UNLEADED 440 <br />❑ 3. DIESEL ❑ 5. JET FUEL ❑ 6. AVIATION GAS <br />❑ 8. PETROLEUM BLEND FUEL ❑ 9. OTHER PETROLEUM (Specify): 440a <br />NON -PETROLEUM: ❑ 7. USED OIL ❑ 10. ETHANOL <br />❑ <br />11. OTHER NON -PETROLEUM (Specify): 440b <br />TYPE OF TANK ❑ 1. SINGLE WALL x 2. DOUBLE WALL ❑ 95. UNKNOWN ""' <br />PRIMARY CONTAINMENT ❑ 1. STEEL X 3. FIBERGLASS ❑ 6. INTERNAL BLADDER 444 <br />❑ 7 STEEL + INTERNAL LINING ❑ 95. UNKNOWN ❑ 99. OTHER (Specify): 444a <br />SECONDARY CONTAINMENT ❑ 1. STEEL X 3. FIBERGLASS ❑ 6. EXTERIOR MEMBRANE LINER ❑ 7. JACKETED 445 <br />❑ 90. NONE ❑ 95. UNKNOWN ❑ 99. OTHER (Specify): 445a <br />OVERFILL PREVENTION ❑ 1. AUDIBLE & VISUAL ALARMS ❑ 2. BALL FLOAT x 3. FILL TUBE SHUT-OFF VALVE 452. <br />❑ 4. TANK MEETS REQUIREMENTS FOR EXEMPTION FROM OVERFILL PREVENTION EQUIPMENT <br />PIPING CONSTRUCTION ❑ I. SINGLE -WALLED <br />x 2. DOUBLE -WALLED ❑ 99. OTHER <br />L_I yu. INVINZ <br />❑ 90. NONE ❑ 99. OTHER (Specify) <br />460 <br />SYSTEM TYPE x 1. PRESSURE <br />❑ 2. GRAVITY <br />❑ 3. CONVENTIONAL SUCTION ❑ 4. SAFE SUCTION [23 CCR §2636(a)(3)] <br />458 <br />PRIMARY CONTAINMENT ❑ 1. STEEL <br />X 4. FIBERGLASS <br />❑ 8. FLEXIBLE <br />❑ 10. RIGID PLASTIC <br />aha <br />❑ 90. NONE <br />❑ 95. UNKNOWN <br />❑ 99. OTHER(Specify): <br />❑ 1. STEEL x 4. FIBERGLASS ❑ 10. RIGID PLASTIC <br />464a <br />SECONDARY CONTAINMENT ❑ L STEEL <br />x 4. FIBERGLASS <br />❑ 8. FLEXIBLE <br />❑ 10. RIGID PLASTIC <br />464b <br />❑ 90. NONE <br />❑ 95. UNKNOWN <br />❑ 99. OTHER (Specify): <br />464c <br />PIPING/TURBINE CONTAINMENT SUMP TYPE <br />❑ 1. SINGLE WALL <br />❑ 2. DOUBLE WALL <br />❑ 90. NONE <br />464d <br />V `SENT, VAPOR;RECOirEIZY (YR} AD- <br />RSC ER'�+'II,L PIPE PIPING Cf3NSTRUC CION <br />VENT PRIMARY CONTAINMENT ❑ 1. STEEL <br />x 4. FIBERGLASS <br />❑ 10. RIGID PLASTIC <br />❑ 90. NONE ❑ 99. OTHER (Specify) <br />464e <br />464e1 <br />VENT SECONDARY CONTAINMENT ❑ L STEEL <br />x 4. FIBERGLASS <br />❑ 10. RIGID PLASTIC <br />❑ 90. NONE ❑ 99. OTHER (Specify) <br />464f <br />46417] <br />VR PRIMARY CONTAINMENT ❑ L STEEL <br />X 4. FIBERGLASS <br />❑ 10. RIGID PLASTIC <br />❑ 90. NONE ❑ 99. OTHER (Specify) <br />4648 <br />464gl <br />VR SECONDARY CONTAINMENT ❑ L STEEL <br />X 4. FIBERGLASS <br />❑ 10. RIGID PLASTIC <br />❑ 90. NONE ❑ 99. OTHER (Specify) <br />464h <br />VENIPIPINU IRANSf11UN SUMP I YPE; <br />RISER PRIMARY CONTAINMENT <br />1J 1. SINULC WALL X L. UDUtlLC WALL <br />x 1. STEEL ❑ 4. FIBERGLASS ❑ 10. RIGID PLASTIC <br />L_I yu. INVINZ <br />❑ 90. NONE ❑ 99. OTHER (Specify) <br />464j <br />464j l <br />RISER SECONDARY CONTAINMENT <br />❑ I. STEEL x 4. FIBERGLASS ❑ 10. RIGID PLASTIC <br />❑ 90. NONE ❑ 99. OTHER (Specify) <br />464k <br />4641 <br />FILL COMPONENTS INSTALLED <br />x 1. SPILL BUCKET x 3. STRIKER PLATE/BOTTOM PROTECTOR x 4. CONTAINMENT SUMP <br />451 a -c <br />❑ 3. NO DISPENSERS ❑ 90. NONE <br />469a <br />CONSTRUCTION TYPE X 1. SINGLE WALL ❑ 2. DOUBLE WALL <br />CONSTRUCTION MATERIAL <br />❑ 1. STEEL x 4. FIBERGLASS ❑ 10. RIGID PLASTIC <br />❑ 99. OTHER (Specify) <br />469b -c <br />STEEL COMPONENT PROTECTION ❑ 2. SACRIFICIAL ANODE(S) ❑ 4. IMPRESSED CURRENT ❑ 6. ISOLATION 448, <br />CERTIFICATION: I certify that this UST system is compatible with the hazardous substance stored and that the information provided herein is true, accurate, <br />and in full compliance with legal requirements. <br />APPLICANT SIGNATURE DATE 470. <br />APPLICANT NAME (print) Dulcinea Covan 471. APPLICANT TITLE Compliance Manager 471 <br />UPCF UST -B -1/1 Rev. (12/2007) <br />