Laserfiche WebLink
LIQUID SENSOR SETUP <br />- - - - - - - - - - - - <br />L 1 :87 ANNULAR <br />DUAL POINT HYDROSTATIC <br />CATEGORY : ANNULAR SPACE V/ <br />L 2:87 SUMP <br />TRI-STATE {SINGLE FLOAT) <br />CATEGORY : STP SUMP <br />L 3:91 ANNULAR I/ <br />DUAL POINT HYDROSTATIC <br />CATEGORY : ANNULAR SPACE <br />L 4:91 SUMP V// <br />TRI-STATE (SINGLE FLOAT) <br />CATEGORY : STP SUMP <br />OUTPUT RELAY SETUP <br />R 1:91 STP <br />TYPE' <br />STANDARD <br />NORMALLY CLOSED <br />TANK #: 2 <br />IN -TANK ALARMS <br />T 2:HIGH WATER ALARM <br />T 2:LOW PRODUCT ALARM <br />LIQUID SENSOR ALMS <br />L 2:FUEL ALARM <br />L 2:SENSOR OUT ALARM <br />L 2:SHORT ALARM <br />ISD SITE ALARMS <br />ISD GROSS PRES FAIL <br />ISD DEGRD PRES FAIL <br />ISD VAPOR LEAK FAIL <br />ISD HOSE ALARMS <br />ALL:GROSS COLLECT FAIL <br />ALL:DEGRD COLLECT FAIL <br />ALL:FLOW COLLECT FAIL <br />R 2:87 STP rx <br />TYPE: kl <br />STANDARD <br />NORMALLY CLOSED <br />TANK #: I <br />IN -TANK ALARMS <br />T I:HIGH WATER ALARM <br />T I:LOW PRODUCT ALARM <br />LIQUID SENSOR ALMS <br />L 4:FUEL ALARM <br />L 4:SENSOR OUT ALARM <br />L 4:SHORT ALARM <br />ISD SITE ALARMS <br />ISD GROSS PRES FAIL <br />ISD DEGRD PRES FAIL <br />ISD VAPOR LEAK FAIL <br />ISD HOSE ALARMS <br />ALL:GROSS COLLECT FAIL <br />ALL:DEGRD COLLECT FAIL <br />ALL:FLOW COLLECT FAIL <br />SMARTSENSOR SETUP <br />- - - - - - - - - - - - <br />I :DISP 1-2 <br />CATEGORY AIR FLOW METER <br />s 2:DISP 3-4 <br />CATEGORY AIR FLOW METER <br />5 3:PRESSURE SENSOR <br />CATEGORY VAPOR PRESSURE <br />EVR/ISD SETUP <br />EVR TYPE: VACUUM ASSIST <br />VACUUM ASSIST TYPE <br />HEALY VAC <br />NOZZLE A/L RANGE <br />MA ,X: 1.15 MIN: 0.95 <br />VAPOR PROCESSOR TYPE <br />NO VAPOR PROCESSOR <br />ANALYSIS TIMES <br />TIME: 12:30 PM <br />DELAY MINUTES: 1 <br />ACCEPT HIGH ORVR: <br />DISABLED <br />ISD <br />HOSE <br />TABLE <br />MAP <br />3: <br />ID <br />FP <br />FL <br />HL <br />AA <br />RR <br />------------------------ <br />01 <br />01 <br />01 <br />02 <br />01 <br />UU <br />02 <br />02 <br />02 <br />02 <br />01 <br />UU <br />03 <br />03 <br />03 <br />02 <br />02 <br />UU <br />04 <br />04 <br />04 <br />02 <br />02 <br />UU <br />ISE) AIRFLOW METER MAP <br />ID SERIAL NUM LABEL <br />------------------------- <br />1 15934 DISP 1-2 <br />2 15325 DISP 3-4 <br />ISD <br />FUEL GRADE <br />HOSE <br />MAP <br />3: <br />1 2 <br />3 <br />4 <br />5: <br />FP <br />MHH MHH <br />MHH <br />MHH <br />AA <br />------------------------- <br />01 <br />301 201 <br />901 <br />U U <br />1 <br />02 <br />202 902 <br />302 <br />U U <br />1 <br />03 <br />303 203 <br />903 <br />U U <br />2 <br />04 <br />204 904 <br />304 <br />U U <br />2 <br />LABEL TABLE <br />1: <br />UNASSIGNED <br />2: <br />BLENDS <br />3: <br />REGULAR <br />4: <br />MID GRADE <br />5: <br />PREM I UM <br />6: <br />GOLD <br />7: <br />BRONZE <br />8: <br />SILVER <br />9: <br />BLEND2 <br />10: <br />BLEND4 <br />PMC SETUP <br />PROCESSOR CONTROL LEVEL: <br />NONE <br />