COMPLIANCE INFO_2006-2013
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
F
>
FREMONT
>
2285
>
2300 - Underground Storage Tank Program
>
PR0231111
>
COMPLIANCE INFO_2006-2013
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/26/2021 9:09:52 AM
Creation date
6/23/2020 6:43:01 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2006-2013
RECORD_ID
PR0231111
PE
2361
FACILITY_ID
FA0001659
FACILITY_NAME
QUIK STOP MARKET #7039
STREET_NUMBER
2285
Direction
E
STREET_NAME
FREMONT
STREET_TYPE
ST
City
STOCKTON
Zip
95205
APN
141-214-03
CURRENT_STATUS
01
SITE_LOCATION
2285 E FREMONT ST
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231111_2285 E FREMONT_2006-2013.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
466
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
UNDER DISPASER CONTAINMENT DC TESTING <br />Test Method By: O Manufacturer 0 Industry Standard o Professional Engr o Other (see below) <br />Test Method Uses: O Pressure O Vacuum • Hydrostatic o Other (see below) <br />Measuring Equipment Used: INCON TS -STS (Electronic Sump Test System) <br />Descrintion Dist) # 1/2 Dist) # 3/4 <br />UDC manufacturer <br />Bravo <br />Bravo <br />UDC material <br />FRP <br />FRP <br />UDC depth (inches) <br />30 <br />30 <br />Height from UDC bottom to highest <br />piping penetration <br />13 <br />12 <br />Height from UDC bottom to lowest <br />electrical penetration <br />6 <br />7 <br />Condition of UDC prior to testing <br />Dry <br />Dry <br />Portion of UDC tested <br />Entire <br />Entire <br />Type of shut -down present <br />Stand Alone <br />Stand Alone <br />Was sensor removed for testing? <br />Yes <br />Yes <br />Was sensor properly replaced after testing? <br />Yes <br />Yes <br />Depth of water level from UDC bottom (in.) <br />15 <br />14 <br />Wait time for water level to stabilize (hr:min) <br />0:10 <br />0:10 <br />Test start time <br />9:33 AM <br />8:07 AM <br />Initial Probe Reading <br />6.0589 <br />5.7385 <br />Test end time <br />9:48 AM <br />8:23 AM <br />Final Probe Reading <br />6.0586 <br />5.7383 <br />Test duration (hr:min) <br />0:15 <br />0:16 <br />Change in water level (± 0.0000 inches) <br />-0.0003 <br />-0.0002 <br />Pass/Fail threshold (±0.0020 inches / } Hr.) <br />0.0020 <br />0.0020 <br />TEST RESULT <br />PASS <br />PASS <br />Comments: <br />0 2006 Walton Engineering, Inc. <br />