Laserfiche WebLink
SAN JOAQUIN COUNTY ENVIRONMENTAL HEALTH DEPARTMENT <br />UNDERGROUND STORAGE TANK <br />MONITORING PLAN - PAGE Z <br />VI. DISPENSER MONITORING <br />MONITORING OF AREAS BENEATH DISPENSER(S) IS PERFORMED USING THE FOLLOWING METHOD(S) (Check all that apply) Msa. <br />ff'1. CONTINUOUS ELECTRONIC MONITORING OF UNDER DISPENSER CONTAINMENT (UDC) <br />PANEL MANUFACTURER Veeder Root (Gilbareo Branded) Msn• MODEL M EMC 16.04 CM-350 equivalent) MS2' <br />LEAK SENSOR MANUFACTURER Veeder Root (Gilbarco Branded) Mme' MODEL #(S): 0848480-001 M54' <br />WILL DETECTION OF A LEAK INTO THE UDC TRIGGER AUDIBLE AND VISUAL ALARMS? a. YES ❑ b. NO mss- <br />WILL A UDC LEAK ALARM TRIGGER AUTOMATIC PUMP SHUTDOWN? ❑ a. YES eb. NO Ms& <br />M"- <br />WILL FAILURE/DISCONNECTION OF UDC MONITORING SYSTEM TRIGGER AUTOMATIC PUMP SHUTDOWN? ❑ a. YES a o. NO <br />❑ 2. MECHANICAL ASSEMBLY (e g , FLOAT AND CHAIN ASSEMBLY) IN UDC TRIPS SHEAR VALVE IN CASE OF LEAK <br />ASSEMBLY MANUFACTURER M-"- MODEL #(S): MO. <br />❑ 3.VLSUAL MONITORING DONE: ❑ a. DAILY [3b. WEEKLY (> mm -w-,Q ' <br />❑ 4. NO DISPENSERS <br />M61. <br />❑ 99. OTHER (Specify) <br />VII. ENHANCED LEAK DETECTION <br />❑ 1. WE HAVE BEEN NOTIFIED BY THE STATE WATER RESOURCES CONTROL BOARD THAT WE MUST IMPLEMENT ENHANCED LEAK M70. <br />DETECTION (ELD) FOR THE UST(S) COVERED BY THIS PLAN. PER 23 CCR §2644.1, ELD IS PERFORMED EVERY 36 MONTHS AS REQUIRED <br />VIII. 111AINING <br />REFS CE LX�UMENTS MAINTAINED AT FACILITY (Check all that apply) M80• <br />1. Mr THIS UNDERGROUND STORAGE TANK MONITORING PLAN (Required) <br />2. OPERATING MANUALS FOR ELECTRONIC MONITORING EQUIPMENT (Required) <br />t,� <br />3. THE FACILITY'S BEST MANAGEMENT PRACTICES (Required as of 1/01!2005) <br />4. ❑ CALIFORNIA UNDERGROUND STORAGE TANK REGULATIONS <br />5. ❑ CALIFORNIA UNDERGROUND STORAGE TANK LAW <br />6. ❑ STATE WATER RESOURCES CONTROL BOARD (SWRCB) PUBLICATION: "HANDBOOK FOR TANK OWNERS - MANUAL AND <br />STATISTICAL INVENTORY RECONCILIATION" <br />7. ❑ SWRCB PUBLICATION: "WEEKLY MANUAL TANK GAUGING FOR SMALL UNDERGROUND STORAGE TANKS" <br />M81. <br />99.[3 OTHER (Specify): <br />Personnel with UST monitoring responsibilities are familiar with all of the above documents relevant to their job duties and can access those documents when needed. <br />By January 1, 2005 this facility will have a "Designated UST Operator' who has passed the operator exam administered by the International Code Council (ICC). By <br />January 1, 2005, and annually thereafter, the "Designated UST Operator' will train facility employees in the proper operation and maintenance of the UST systems. <br />This training will include, but is not limited to, the following: <br />➢ Operation of the UST systems in a manner consistent with the facility's best management practices. <br />The facility employee's role with regard to the leak detection equipment. <br />A The facility employee's role with regard to spills and overfills. <br />A Whom to contact for emergencies and leak detection alarms. <br />For facility employees hired on or after January I, 2005, the initial taming will be conducted within 30 days of the date of hire. <br />IX. CO NTSIADDITIONAL INFORMATION <br />Please use this section to include any additional UST system nmitoring-related information (e.g., additional information required by your local agency): Mss• <br />Overfill prevention (or protection) is accomplished by the following two (2) methods: <br />1) Mechanical overfill valves (OPW 61 SO) installed in drop tubes, <br />2) All service penetrations to the primary containment are contained within sumps, including the fill and vapor return. <br />X. PERSONNEL RESPONSIBILITIES <br />AS OF 1/1/05, THE "DESIGNATED UST OPERATOR" IDENTIFIED IN SECTION III OF THE CURRENT UST OPERATING PERMIT APPLICATION — <br />FACILITY FORM WILL HAVE ULTIMATE AUTHORITY FOR PERFORMING THE MONITORING ACTIVITIES AND MAINTAINING LEAK DETECTION <br />EQUIPMENT COVERED BY THIS PLAN, AND WILL PERFORM AND DOCUMENT MINIMUM MONTHLY VISUAL INSPECTIONS OF THE FACILITY'S <br />UST SYSTEMS IN ACCORDANCE WITH 23 CCR 12715 . <br />XI. OWNER/OPERATOR SIGNATURE <br />CERTIFICATION: I certify that the Information provided herein is true and accurate to the best of my knowledge. <br />OWNER/OPERATOR SIGNATURE $F <br />DATE: Mgt. <br />� Owner nee. <br />❑ Operator <br />October 15.2007 <br />OWNER/OPERATOR NAME (print): M91 <br />OWNER/OPERATOR TTTL.E: ' <br />Mike Karvelot, for Quik Stop Markets, Inc. <br />Director of Envirommental Affairs <br />(Agency Use Only) This plan has been reviewed and: Approved ❑ Approved With Conditions ❑ Disapproved <br />Local Agency Signature: Date: b U <br />Comrrents/Special Conditions: <br />SJCEEM4 (07/03) -3/4 vnwiva <br />