My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2013-2017
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
F
>
FREMONT
>
2285
>
2300 - Underground Storage Tank Program
>
PR0231111
>
COMPLIANCE INFO_2013-2017
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/26/2021 9:48:20 AM
Creation date
6/23/2020 6:43:02 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2013-2017
RECORD_ID
PR0231111
PE
2361
FACILITY_ID
FA0001659
FACILITY_NAME
QUIK STOP MARKET #7039
STREET_NUMBER
2285
Direction
E
STREET_NAME
FREMONT
STREET_TYPE
ST
City
STOCKTON
Zip
95205
APN
141-214-03
CURRENT_STATUS
01
SITE_LOCATION
2285 E FREMONT ST
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231111_2285 E FREMONT_2013-2017.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
402
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
UNDER DISPENSER CONTAINMENT (UDC) TESTING <br />Test Method By: o Manufacturer • Industry Standard o Professional Engr o Other (see below) <br />Test Method Uses: o Pressure o vacuum • Hydrostatic o Other (see below) <br />Measuring Equipment Used: INCON TS -STS (Electronic Sump Test System) <br />Descrintion Disn # 3/4 Disn # 3/4 <br />UDC manufacturer <br />Bravo <br />Bravo <br />UDC material <br />FRP <br />FRP <br />UDC depth (inches) <br />32 <br />32 <br />Height from UDC bottom to highest <br />piping penetration <br />10 <br />10 <br />Height from UDC bottom to lowest <br />electrical penetration <br />12 <br />12 <br />Condition of UDC prior to testing <br />Dry <br />Dry <br />Portion of UDC tested <br />Entire <br />Entire <br />Type of shut -down present <br />Sensor <br />Sensor <br />Was sensor removed for testing? <br />Yes <br />Yes <br />Was sensor properly replaced after testing? <br />Yes <br />Yes <br />Depth of water level from UDC bottom (in.) <br />15 <br />15 <br />Wait time for water level to stabilize (hr:min) <br />:10 <br />:10 <br />Test start time <br />9:48 AM <br />9:48 AM <br />Initial Probe Reading <br />4.6764 <br />3.2211 <br />Test end time <br />10:03 AM <br />10:03 AM <br />Final Probe Reading <br />4.6764 <br />3.2209 <br />Test duration (hr:min) <br />0:15 <br />0:15 <br />Change in water level (± 0.0000 inches) <br />0.0000 <br />-0.0002 <br />Pass/Fail threshold (±0.002 inches / ; Hr.) <br />0.0020 <br />0.0020 <br />TEST RESULT <br />PASS <br />PASS <br />Comments: <br />IEivy iRONMENTAL HEALTH <br />DEPARTMENT <br />© 2016 Walton Engineering, Inc. <br />