Laserfiche WebLink
� • REGs=4tifF_D <br />San Joaquin County <br />Environmental Health Department _ <br />1868 East Hazelton Avenue, Stockton, California 95205-6232 ENVERQNM�«°��� N�`�L <br />Telephone: (209) 468-3420 Fax: (209) 468-3433 Web: www.sjgov.org/ehd ��Ps,,�T�,� NT <br />Underground Storage Tank Program Inspection Report <br />Facility Name: <br />Facility Address: <br />Date: <br />QUIK STOP MARKET #7039 <br />2285 E FREMONT ST, STOCKTON <br />August 08, 2017 <br />SUMMARY OF VIOLATIONS <br />(CLASS t, CLASS II, or MINOR -Notice to comply) <br />Item # <br />Remarks <br />318 <br />CCR 2636(f)(2) Leak detector failed to detect a 3.0 gph leak at 10 psi. <br />The 91 octane VMI line leak detector failed to detect a leak when tested. All line leak detectors shall be capable of <br />detecting a 3 -gallon per hour leak at 10 psi. The service technician adjusted the leak detector, retested it, and it <br />passed. <br />This was corrected on site. <br />This is a repeat violation, Class II. <br />319 <br />CCR 2635(b) No spill bucket, failed to contain five gallons, or failed to provide a means to keep it empty. <br />The 87 octane spill container failed when tested. All spill containers shall have a minimum capacity of five gallons <br />and be capable of containing a spill or overfill until it is detected or cleaned up. The service technician tightened the <br />adapter, retested and passed. <br />This was corrected on site. <br />This is a minor violation. <br />Overall Inspection Comments: <br />Complete and submit a copy of the Return to Compliance Certification form to the EHD with a statement <br />documenting the corrective actions that have been or will be taken for each violation, and any supporting <br />paperwork, by September 7, 2017 . <br />Please be aware that as of January 1, 2014, facility operators are required to upload the following UST program <br />documents into the California Environmental Reporting System (GFRs): UST Monitoring Site Plan, UST <br />Certification of Financial Responsibility, UST Response Plan, UST Letter from Chief Financial Officer (if <br />applicable), and the Owner Statement of Designated Operator Compliance. The UST Owner/Operator: Written <br />Agreement, if applicable, can be stored at the facility or uploaded into CERS. <br />AFTER THE COMPLIANCE DATE, EHD WILL BILL FOR ALL TIME AND ACTIVITIES ASSOCIATED WITH BRINGING <br />THIS FACILITY BACK INTO COMPLIANCE. <br />THIS FACILITY IS SUBJECT TO REINSPECTION AT ANY TIME AT EHD'S CURRENT HOURLY RATE. <br />Received by: Date: August 08, 2017 <br />Inspector: <br />Inspector Phone: <br />Printed Name and Title; <br />CESAR RUVALCABA, EHS Trainee <br />(209) 953-6213 <br />Kulgit Gill, Franchisee <br />FA0001859 PR0231111 SC001 08/08/2017 <br />EHD 23-01 Rev. 09/22/18 Page 5 of 5 Underground Storage Tank Program OIR <br />