COMPLIANCE INFO_1996-2004
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
H
>
HAMMER
>
1210
>
2300 - Underground Storage Tank Program
>
PR0231125
>
COMPLIANCE INFO_1996-2004
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/24/2024 11:40:15 AM
Creation date
6/23/2020 6:43:31 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1996-2004
RECORD_ID
PR0231125
PE
2361
FACILITY_ID
FA0003730
FACILITY_NAME
TIWANA GAS & FOOD
STREET_NUMBER
1210
Direction
E
STREET_NAME
HAMMER
STREET_TYPE
LN
City
STOCKTON
Zip
95210
APN
09403012
CURRENT_STATUS
01
SITE_LOCATION
1210 E HAMMER LN
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231125_1210 E HAMMER_1996-2004.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
406
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
TEST DATE:07/10/01 <br />CLIENT:ULTRAMAR INC <br />Tank ID: #1 <br />Product: UNLEADED <br />Capacity in gallons: 12,041 <br />Diameter in inches: 128.00 <br />Length in inches: 218 <br />Material: DW STEEL <br />COMMENTS <br />Dipped Water Level: <br />Dipped Product Level: <br />Probe Water Level: <br />Ingress Detected: Water <br />Test time: <br />Inclinometer reading: <br />VacuTect Test Type: <br />VacuTect Probe Entry Point: <br />Pressure Set Point: <br />Tank water level in inches: <br />Water table depth in inches: <br />Determined by (method): <br />Result: <br />COMMENTS <br />TANK INFORMATION ANI <br />8900 SHOAL CREEK, BUILDING 200 <br />AUSTIN, TEXAS 78757 (512) 451-6334 <br />1 Tank manifolded: No <br />Vent manifolded: yEs <br />Vapor recovery manifolded: yEs <br />Overfill protection: yEs <br />Overspill protection: yEs <br />Installed: ATG <br />CP installed on: / / <br />Bubble Ullage <br />Impact Valves Operational: yES <br />COMMENTS <br />T RESULTS <br />WORK ORDER NUMBER2217647 <br />SITE:ULTRAMAR 641 <br />Bottom to top fill in inches: <br />192.0 <br />Bottom to grade in inches: <br />199.0 <br />Fill pipe length in inches: <br />64.0 <br />Fill pipe diameter in inches: <br />4.0 <br />Stage I vapor recovery: <br />DUAL <br />Stage 11 vapor recovery: <br />ASSIST <br />New/passed Failed/replaced New/passed Failed/replaced <br />L.D. #1 L.D. #1 L.D. #2 L.D. #2 <br />Make: RED JACKET <br />Model: <br />Fx1v <br />S/ISI: <br />105989608 <br />Open time in sec: <br />2.00 <br />Holding psi: <br />14 <br />Resiliency cc: <br />70 <br />est leak rate ml/m: <br />189.0 <br />Metering psi: <br />10 <br />Calib. leak in gph: <br />3.00 <br />Results: <br />PASS <br />COMMENTS <br />Material: DW FIBERG <br />Diameter (in): <br />2.0 <br />Length (ft): <br />100.0 <br />Test psi: <br />60 <br />Bleedback cc: <br />150 <br />Test time (min): <br />30 <br />Test 1: Start time: <br />10:09 <br />Finish psi: <br />57 <br />Vol change cc: <br />9 <br />Test 2: Start time: <br />10:20 <br />Finish psi: <br />5e <br />Vol change cc: <br />7 <br />Test 3: Start time: <br />10:31 <br />Finish psi: <br />59 <br />Vol change cc: <br />4 <br />Final gph: <br />0.011 <br />Result: <br />PASS <br />Pump type: <br />PRESSURE <br />Pump make: <br />RED JACKET <br />NOT NOT NOT <br />TESTED TESTED TESTED <br />07/17/2001 12:33 <br />