My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_1996-2004
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
H
>
HAMMER
>
1210
>
2300 - Underground Storage Tank Program
>
PR0231125
>
COMPLIANCE INFO_1996-2004
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/24/2024 11:40:15 AM
Creation date
6/23/2020 6:43:31 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1996-2004
RECORD_ID
PR0231125
PE
2361
FACILITY_ID
FA0003730
FACILITY_NAME
TIWANA GAS & FOOD
STREET_NUMBER
1210
Direction
E
STREET_NAME
HAMMER
STREET_TYPE
LN
City
STOCKTON
Zip
95210
APN
09403012
CURRENT_STATUS
01
SITE_LOCATION
1210 E HAMMER LN
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231125_1210 E HAMMER_1996-2004.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
406
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
IN <br />TEST DATE: 08/05/98 <br />CLIENT: ULTRAMAR INC <br />REPORT <br />WORK ORDER NUMBER: 2205434 <br />SITE: ULTRAMAR 641 <br />Tank ID: 87 1 <br />Material:Dw STEEL <br />Bottom to top fill in inches: <br />192.0 <br />Product: REG UNLEAD <br />Tank manifolded: No <br />Bottom to grade fill in inches: <br />199.0 <br />Capacity in gallons: 12,041 <br />Vent manifolded: YES <br />Fill pipe length in inches: <br />64.0 <br />Diameter in inches: 128.00 <br />Vapor recovery manifolded: YES <br />Fill pipe diameter in inches: <br />4.0 <br />Length in inches: 218 <br />Impact Valves Operational: Y <br />Stage I vapor recovery: <br />DUAL <br />Tank age (years): <br />Overfill protection: YEs <br />Stage II vapor recovery: <br />ASSIST <br />Fuel pure rating: <br />Overspill protection: YEs <br />Installed: <br />ATG <br />CP installed on: / <br />/ <br />COMMENTS <br />Dipped Water Level: <br />Dipped Product Level: <br />Probe Water Level: <br />Ingress Detected: Water Bubble <br />Test time: <br />VacuTect Test Type: <br />VacuTect Probe Entry Point: <br />Pressure Set Point: <br />Tank water level in inches: <br />Water table depth in inches: <br />Determined by (method): <br />Result: <br />COMMENTS <br />n® tin/ New/passed Failed/reply <br />L.D. #1 L.D. #1 <br />Make: RED JACKET <br />Model: Fx1 <br />Ullage S/N: 0425965779 <br />Open time in sec: 3.00 <br />Holding psi: 11 <br />Resiliancy cc: 140 <br />Test leak rate ml/m: 189.0 <br />Metering psi: 10 <br />Calib. leak in gph: 3.00 <br />Results: PAss <br />COMMENTS <br />New/passed Failed/replaced <br />L.D. #2 L.D. #2 11 <br />8900 SHOAL CREEK, BUILDING 200, AUSTIN, TEXAS 78757 (512) 451-6334 Draft 08/11/98 07:56 MSHAW <br />
The URL can be used to link to this page
Your browser does not support the video tag.