Laserfiche WebLink
SUPERTANK", <br />CONTAINMENT: <br />/Sump Risers�� <br />Rings <br />1• <br />500 <br />H O <br />1,000 <br />Mon <br />Witl <br />- r 'u,+ <br />Anne <br />L I <br />6-5 3/8" 51" 46" 4,000 3/16" <br />675 <br />1,087 <br />4'-5 3/8" <br />70" <br />65" <br />5,500 <br />3/16" <br />1,000 <br />1,404 <br />6'-53/8" <br />70" <br />65" <br />8,000 <br />3/16" <br />2,000 <br />2,319 <br />12'-4 5/8" <br />70" <br />65" <br />15,500 <br />3/16" <br />2,500 <br />2,777 <br />15-4 5/8" <br />70" <br />65" <br />19,500 <br />3/16" <br />3,000 <br />3,233 <br />18'-4 5/8" <br />70" <br />65" <br />23,000 <br />3/16" <br />3,000 <br />3,706 <br />8'-81/2" <br />102" <br />97" <br />10,700 <br />3/16" <br />4,000 <br />4,147 <br />24'-41/2" <br />70" <br />65" <br />29,500 <br />1/4" <br />4,000 <br />4,397 <br />11'-11/4" <br />102" <br />97" <br />30,500 <br />3/16" <br />5,000 <br />5,186 <br />13'-9 3/8" <br />102" <br />97" <br />38,500 <br />1/4" <br />6,000 <br />6,171 <br />17'-13/8" <br />102" <br />97" <br />48,500 <br />1/4" <br />8,000 <br />7,745 <br />22'-4 5/8" <br />102" <br />97" <br />63,500 <br />1/4" <br />10,000 <br />8,102 <br />15-101/2" <br />134 3/8" <br />129 3/8" <br />78,000 <br />1/4" <br />10,000 <br />9,124 <br />27'-0 5/8" <br />102" <br />97" <br />77,000 <br />1/4" <br />12,000 <br />9,306 <br />18'-11112" <br />134 3/8" <br />129 3/8" <br />93,900 <br />1/4" <br />12,000 <br />10,698 <br />32'-3 7/8" <br />102" <br />97" <br />92,500 <br />1/4" <br />15,000 <br />14,177 <br />23'-7 7/8" <br />134 3/8" <br />129 3/8" <br />118,000 <br />1/4" <br />16,000 <br />14,877 <br />24'-41/2" <br />134 3/8" <br />129 3/8" <br />125,400 <br />5/16" <br />20,000 <br />17,680 <br />30'-3 3/8" <br />134 3/8" <br />129 3/8" <br />155,000 <br />5/16" <br />25,000 <br />24,348 <br />37'-71/4" <br />134 3/8" <br />129 3/8" <br />190,000 <br />3/8" <br />30,000 <br />27,277 <br />36-4 3/4" <br />148 <br />143 <br />228,000 <br />3/8" <br />40,000 <br />32,527 <br />49'-0" <br />148 <br />143 <br />308,000 <br />3/8" <br />iitor Well <br />12" Fittings <br />alar Space <br />Sample Specification The contractor shall provide the SuperTank® The primary tank shall be <br />built to UL 58 construction standards with the full thickness of steel listed in Table 3.1 of UL 58. The primary <br />tank shall be isolated from the external environment and secondarily contained by Fiberglass Reinforced <br />Plastic (200 mil nominal thickness) which is not attached to the tank except at the fittings. The primary tank <br />shall be factory tested to 5 psi internal pressure. Prior to shipment, the annular space shall be proof tested by <br />vacuum only to 20" hg vacuum. The double wall tank shall have been tested in accordance with UL 1746 <br />and shall bear an external label indicating that the complete tank is UL listed as a jacketed secondary <br />containment tank. <br />Patent #5,047,101 and #5,102,005 <br />