My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
H
>
HAMMER
>
1210
>
2300 - Underground Storage Tank Program
>
PR0231125
>
COMPLIANCE INFO_2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/8/2021 4:41:49 PM
Creation date
6/23/2020 6:43:49 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2018
RECORD_ID
PR0231125
PE
2361
FACILITY_ID
FA0003730
FACILITY_NAME
TIWANA GAS & FOOD
STREET_NUMBER
1210
Direction
E
STREET_NAME
HAMMER
STREET_TYPE
LN
City
STOCKTON
Zip
95210
APN
09403012
CURRENT_STATUS
01
SITE_LOCATION
1210 E HAMMER LN
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
KBlackwell
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231125_1210 E HAMMER_2018.tif
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
158
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Parkwood Gas& Food 2 98888157 p.16 <br /> F. In-Tank Gauging t SIR Equipment: ® Check this box if tank gauging is used only for inventory control. <br /> ❑ Check this box if no tank gauging or SfR equipment is installed. <br /> This section must be completed;f in-tank gauging equipment is used to perform leak detection monitoring. <br /> Complete the following checklist: <br /> ® Yes ❑ Ni Has all input wiring been inspected for proper entry and termination,including tes'ing for ground faults? <br /> ® Yes ❑ No' were all tank gauging probes visually inspected for damage and residue buildup? <br /> ® Yes ❑ No` was accuracy of system product level readings tested? <br /> ® Yes ❑ No- was accuracy of system water level readings tested? <br /> ® Yes ❑ No- Were all probes reinstalled properly? <br /> ® Yes ❑ No- were all items on the equipment manufacturer's maintenance checklist completed? <br /> In Section H,below,describe how and when these deficiencies were or will be corrected. <br /> Line Leak Detectors(LLD): ❑ Check this box if LLDs are not installed. <br /> Complete the followingchecklist: <br /> ® Yes ❑ No' For equipment start-up or annual equipment certification, was a leak simulated to verify LLD performance? (Check air that apply) <br /> ❑ NIA Simulated leak rate ®3 g,p.h.; ❑0.1 g.p.h; Q 0.2 g.p.h. <br /> ® Yes ❑ No' Were all LLDs confirmed operational and accurate within regulatory requirements? <br /> ® Yes ❑ No' Was the testing apparatus properly calibrated? <br /> ® Yes ❑ No' For mechanical LLDs,does the LLD restrict product flow if it detects a leak? <br /> ❑ N/A <br /> ❑ Yes ❑ No` For electronic LLDs,does the turbine automatically shut off if the LLD detects a leak? <br /> ® N/A <br /> ❑ Yes ❑ No- For electronic LLDs does the turbine automatically shut off it any portion of the monitoring system is disabled cr disconnected? <br /> ® <br /> NIA <br /> Q Yes ❑ No' For electronic LLDs,does the turbine automaticalfy shut off if any portion of the monitoring system malfunctions orfais a test? <br /> ® N!A <br /> ❑ Yes ❑ No' For electronic LLDs,have all accessible wiring connections been visually iispected? <br /> ® N!A <br /> 13 Yes ❑ No' Were all items on the equipment manufaciure•'s maintenance checklist completed? <br /> In Section H,below,describe how and when these deficiencies were or will be corrected. <br /> H. Comments: <br /> VA,; M. <br /> �i <br /> UI. <br /> Monitoring System Certification Page 3 of 4 212 1/O7 <br /> Received Time Ju1. 25. 2018 10:46AM No, 3918 <br />
The URL can be used to link to this page