Laserfiche WebLink
A <br />DETECTOR <br />NDE ENVIRONMENTAL i''•`A <br />TEST DATE: November 9, 1994 WORK ORDER NUMBER: 963167 <br />CLIENT. TOSCO NORTHWEST COMPANY SITE: B.P. 1-1191 <br />Tank ID: <br />3 <br />Bottom to top fill in inches: <br />147.0 <br />Product: <br />PLUS <br />Bottom to grade fill in inches: <br />153.0 <br />Capacity in gallons: <br />6,085 <br />Fill pipe length in inches: <br />56.0 <br />Diameter in inches: <br />91.00 <br />Fill pipe diameter in inches: <br />4.0 <br />Length in inches: <br />219 <br />Stage I vapor recovery: <br />COAX <br />Material: <br />DW FIBERG <br />Stage II vapor recovery: <br />BALANCE <br />Tank: <br />No <br />50 <br />vol change cc: <br />Manifolded Vent: <br />No <br />0.008 <br />RESULT. <br />Test method: <br />vPLT <br />Psi at tank bottom: <br />1.77 <br />Fluid level in inches: <br />68.10 <br />UFT/OFT <br />LIFT <br />Fluid volume in gallons: <br />4,884 <br />Water level in inches: <br />0.00 <br />Test time: <br />13:50-17:19 <br />Number of thermisters: <br />5 <br />Specific gravity: <br />0.746 <br />Water table depth in inches: <br />166.00 <br />Determined by (method): <br />MONTR WELL <br />Leak rate in gph: <br />-0.019 <br />RESULT. <br />PASS <br />New/passed Failed/replaced <br />detector detector <br />Test method: PTA <br />Make: RED JACKET <br />Model: X.L.D. <br />S/N: 407931294 <br />Open time in sec: 3.00 <br />Holding psi: 10 <br />Resiliency cc: 285 <br />;t leak rate ml/min: 189.0 <br />Metering psi: 10 <br />Calib. leak in gph: 3.00 <br />RESULT PASS <br />£OI MEt�ITS : ENTS <br />Test method: VTS-4T System <br />Test time: 17:30-18:10 <br />Ullage volume: 1,201 <br />Ullage pressure: 2.23 <br />RESULT: PASS <br />DATA FOR UTS-4T ONLY: <br />Time of test 1: 17:40-17:50 <br />Temperature: 73.90 <br />Flow rate (cfh): 0.200-0.200 <br />Time of test 2: 17:50-18:00 <br />Temperature: 73.90 <br />Flow rate (cfh): 0.200-0.200 <br />Time of test 3: 18.,00-18:10 <br />Temperature: 73.80 <br />Flow rate (cfh): 0.200-0.200 <br />Mt�T'f'S <br />WALL <br />Material: STEEL <br />Diameter (in): <br />2.0 <br />Length (ft): <br />75.0 <br />Test psi: <br />50 <br />Bleedback cc: <br />40 <br />Test time (min): <br />30 <br />Test 1: start time: <br />09:25 <br />finish psi: <br />48 <br />vol change cc: <br />10 <br />Test 2: start time: <br />09:35 <br />finish psi: <br />49 <br />vol change cc: <br />5 <br />Test 3: start time: <br />09:45 <br />finish psi: <br />50 <br />vol change cc: <br />0 <br />Final gph: <br />0.008 <br />RESULT. <br />PASS <br />Test type: PTR -88 <br />Pump type: PRESS Pump make: <br />RED JACKET <br />