My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_1987-1998
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
H
>
HAMMER
>
1469
>
2300 - Underground Storage Tank Program
>
PR0231126
>
COMPLIANCE INFO_1987-1998
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/9/2021 10:18:52 AM
Creation date
6/23/2020 6:44:09 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1987-1998
RECORD_ID
PR0231126
PE
2361
FACILITY_ID
FA0001570
FACILITY_NAME
UNITED # 5447
STREET_NUMBER
1469
Direction
E
STREET_NAME
HAMMER
STREET_TYPE
LN
City
STOCKTON
Zip
95210
APN
08818030
CURRENT_STATUS
01
SITE_LOCATION
1469 E HAMMER LN
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231126_1469 E HAMMER_1987-1998.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
427
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ALAND <br /> NOLOG VacuTectTm TEST REPORT y <br /> O. # 077316 <br /> LOGY FOR TANKS <br /> IR ENVIRONMENT <br /> Date 11/05/92 <br /> Owner B.P. OIL Site # 11191 <br /> t i �HEALTH <br /> Invoice Name/Address B.P. OIL 2868 PROSPECT PARK DR. ST RANCHO CORDOVA CA 95670 (t5EVsg4CESPhone <916> 631-6915 <br /> Attn: LOU PARIS I <br /> Site Name/Address B.P. OIL 1469 E HAMMER LANE STOCKTON, CA <br /> TANKS LINES Leak Det <br /> Ullage TANKS and LINES Tested to CFR-40 Parts <br /> See Tank Di p 280-281 &NFPA 329 Spec's. <br /> Dia, <br /> peed Dipped Probe Water Bubble Air Line Final Exist <br /> For Dia.& Water Product Water Ingress Ingress Ingress TANK Line Delivery LINE LINE Leak LINE LD(s) NEW <br /> Loc Material Level Level Level Detected Detected Detected ■ Material Syst.Type TEST TEST Rate ■ Pass/ LD(s) <br /> ST/ ■ ■ ■ ■ ■ ■ Tight ■ ■ ■ ■ ■ Tight Fail/ Tested Other: <br /> k Tank Tank FRP/ START START START or ST/ START END or or & <br /> # Product Capacity Lined END END END Yes/No Yes/No Yes/No Fail Line# FRP PS/SS/GS TIME TIME GPH Fail NONE PASS <br /> 1 REG 12000 Diameter 0.000 074.00 00.1.60 N N N T 1A FRP PS 2:02 12:32 0.000 T P N Exist LD SN/MDL/MFG: 41091-3978 <br /> UNL 92 )0 .000 0 7 4 .0 0 00 . 160 New LC SN/MDL/MFG <br /> Material 10: 31 Time of of Nil at 8 0.0 Pump <br /> RED JACKET LINE TEST PSI 50. 00 <br /> Start Time: m <br /> FRP End Time: 13 : 37 Tank t PSI:— • 9 0 Ernt e F ILL Inclr es:' l. . 700 O sepe^at,ier earno Valves V <br /> SUPR 0000 Diameter .000 Q 00.160 N N N T 2A FRP PS 2:39 13:09 0.000 T P N Exist LII SN/MDL/MFG: 410191-3977 <br /> UNL 92 310 .000 0 7 6 .0 0 00 . 1601 1 New LG SN/MDL/MFG: <br /> -ffaterta 10: 31 Time of Test a` 8 2.0 Mfmp RED JACKET LINE TEST PSI 50.00 <br /> Start Time: <br /> an robe nc inom. aL 2 .O O O Dlspen ier Shear Valves V <br /> FRP End Time: 13% 3 7 Test PSI:— • 9 Entry:: FILL De reel: o Brat. es/no 1 <br /> 3 NO 6000 <br /> Diameter 0,000 073.00 0.160 N N N T 3A FRP PS 4:23 14:59 0.000 T — N Exist LJ SN/MDL/MFG: <br /> LEAD 92 0.000 073.00 00 . 160 vh�c�.�Pfb� <br /> New L(�SN/MDL/MFG: <br /> PLUS <br /> Material Start Time: 14 :0 6 Time of Test a` 7 9.0 Mfg.. RED JACKET LINE T ST PSI 50.00 <br /> FRP End Tim : 16 :13 T nt PSI:— . 90 En a FILL Dc mo seter 1. 8 O O Openatpen a Shear Valves <br /> O era r es/no <br /> 4 DIE 6000 Diameter 0.000 063.00 00.360 N N N T 4A FRP PS 5:06 15:36 0.000 T P N Exist LlSN/MOL/MFG: N/A V h eta 4b C <br /> 9 2 0 .0 0 0 0 6 3 .0 0 00 . 5801 New Lt SN/MDL/MFG: <br /> atenal 14:06 Time of Test I at 68 .0 Mfmp RED JACKET LINE TEST PSI 50.00 <br /> Start Time: g.: <br /> �. FRP En Time: 16 : 1 3 T n PSI.— . 9 0 Entre F ILL inclinometer L. 80 0 Dispenser Shear Valves <br /> Diameter <br /> Exist U)SN/MDL/MFG: <br /> New Lf,SN/MDL/MFG: <br /> -ga—terial Percent of Fill at Pump LINE TLST PSI: <br /> Start Time: Time of Test: Mfg.: <br /> an roenc inometer Dispenser Shear valves <br /> En Time: Test PSI: En r : D r O erate(yes/no) <br /> Diameter <br /> Exist L7 SN/MDL/MFG: <br /> New LD SN/MOL/MFG: <br /> Material nt of Fillat Pump <br /> Start Time: Time of Test: Mfg.: LINE TEST PSI: <br /> End Tim T nt PSI: Ent a Inc lfometer Dispenser Shear valves <br /> Operate es/no <br /> Tanknology Corporation International <br /> TANRNOLOGY Region: WESTERN REGION Unit # 017 State Lic. # State: .CA 5225 Hollister St., Houston, TX 77040 <br /> NOTE: Original VacuTect Data recordings are reviewed by Tanknology's Audit Control Department and maintained on file. (800) 885-8'5563 • FAX (713) 690-2255 <br /> TAK-01 • <br />
The URL can be used to link to this page
Your browser does not support the video tag.